Blood flow effects in a patient with a thoracic aortic endovascular prosthesis

被引:0
|
作者
Tello, Juan P. [1 ]
Velez, Juan C. [1 ]
Cadena, Alberto [2 ]
Jutinico, Andres [3 ]
Pardo, Mauricio [1 ]
Percybrooks, Winston [1 ]
机构
[1] Univ Norte, Km 5 Via Puerto Colombia, Barranquilla, Colombia
[2] Clin Costa, Barranquilla, Colombia
[3] Univ Distrital Francisco Jose Caldas, Bogota, Colombia
关键词
Blood flow; Velocity profiles; Pressure distributions; Image processing; Aorta; Cross section; Endovascular prosthesis; STENT-GRAFT MODELS; SHEAR-STRESS; NUMERICAL-SIMULATION; HEMODYNAMICS; RESTENOSIS; STENOSIS; ARTERIES; REPAIR;
D O I
10.1016/j.heliyon.2024.e26355
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This work analyzes hemodynamic phenomena within the aorta of two elderly patients and their impact on blood flow behavior, particularly affected by an endovascular prosthesis in one of them (Patient II). Computational Fluid Dynamics (CFD) was utilized for this study, involving measurements of velocity, pressure, and wall shear stress (WSS) at various time points during the third cardiac cycle, at specific positions within two cross sections of the thoracic aorta. The first cross-section (Cross -Section 1, CS1) is located before the initial fluid bifurcation, just before the right subclavian artery. The second cross-section (Cross -Section 2, CS2) is situated immediately after the left subclavian artery. The results reveal that, under regular aortic geometries, velocity and pressure magnitudes follow the principles of fluid dynamics, displaying variations. However, in Patient II, an endoprosthesis near the CS2 and the proximal border of the endoprosthesis significantly disrupts fluid behavior owing to the pulsatile flow. The cross-sectional areas of Patient I are smaller than those of Patient II, leading to higher flow magnitudes. Although in CS1 of Patient I, there is considerable variability in velocity magnitudes, they exhibit a more uniform and predictable transition. In contrast, CS2 of Patient II, where magnitude variation is also high, displays irregular fluid behavior due to the endoprosthesis presence. This cross-section coincides with the border of the fluid bifurcation. Additionally, the irregular geometry caused by endovascular aneurysm repair contributes to flow disruption as the endoprosthesis adjusts to the endothelium, reshaping itself to conform with the vessel wall. In this context, significant alterations in velocity values, pressure differentials fluctuating by up to 10%, and low wall shear stress indicate the pronounced influence of the endovascular prosthesis on blood flow behavior. These flow disturbances, when compounded by the heart rate, can potentially lead to changes in vascular anatomy and displacement, resulting in a disruption of the prosthesis -endothelium continuity and thereby causing clinical complications in the patient.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] ENDOVASCULAR MANAGEMENT OF DESCENDING THORACIC AORTIC RUPTURE
    Fernandez Carmona, A.
    Olivencia Pena, L.
    Diaz Redondo, A.
    Gonzalez Martin, F. M.
    Rayo Bonor, A.
    Frias Pareja, J. C.
    INTENSIVE CARE MEDICINE, 2009, 35 : 59 - 59
  • [32] Simulation of unsteady blood flow dynamics in the thoracic aorta
    Lain, Santiago
    Caballero, Andres D.
    INGENIERIA E INVESTIGACION, 2017, 37 (03): : 92 - 101
  • [33] Biomechanical implications of the fenestration structure after thoracic endovascular aortic repair
    Qiao, Yonghui
    Mao, Le
    Zhu, Ting
    Fan, Jianren
    Luo, Kun
    JOURNAL OF BIOMECHANICS, 2020, 99
  • [34] Reducing Prosthesis-Patient Mismatch With Edwards Magna Prosthesis for Aortic Valve Replacement
    Kume, Yuta
    Fujita, Tomoyuki
    Fukushima, Satsuki
    Hata, Hiroki
    Shimahara, Yusuke
    Matsumoto, Yorihiko
    Yamashita, Kizuku
    Kobayashi, Junjiro
    CIRCULATION JOURNAL, 2017, 81 (04) : 468 - 475
  • [35] Computational Fluid Analysis of Blood Flow Characteristics in Abdominal Aortic Aneurysms Treated with Suprarenal Endovascular Grafts
    Sun, Zhonghua
    Chaichana, Thanapong
    Sangworasil, Manas
    Tungjitkusolmun, Supan
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1728 - +
  • [36] Pulsatile Flow Investigation in Development of Thoracic Aortic Aneurysm: An In-Vitro Validated Fluid Structure Interaction Analysis
    Ong, C. W.
    Kabinejadian, F.
    Xiong, F.
    Wong, Y. R.
    Toma, M.
    Nguyen, Y. N.
    Chua, K. J.
    Cui, F. S.
    Ho, P.
    Leo, H.
    JOURNAL OF APPLIED FLUID MECHANICS, 2019, 12 (06) : 1855 - 1872
  • [37] Analysis of the effects of different pulsatile inlet profiles on the hemodynamical properties of blood flow in patient specific carotid artery with stenosis
    Piskin, Senol
    Celebi, M. Serdar
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (06) : 717 - 728
  • [38] Endovascular stent-grafts for thoracic aortic disease
    Eggebrecht, H
    Baumgart, D
    Herold, U
    Rasusch, S
    Naber, C
    Haude, M
    Barkhausen, J
    Jakob, H
    Erbel, R
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2002, 33 (12) : 779 - 785
  • [39] Endovascular treatment for acute traumatic thoracic aortic transection
    Ergun, Onur
    Canyigit, Murat
    Hidiroglu, Mete
    Tatar, Idil Gunes
    Birgi, Erdem
    Kucuker, Aslihan
    Uguz, Emrah
    Durmaz, Hasan Ali
    Cetin, Huseyin
    Hekimoglu, Baki
    Sener, Erol
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2015, 21 (04): : 285 - 290
  • [40] Endovascular Stent Grafting for Acute Thoracic Aortic Pathology
    Albors, Jose
    Angel Bahamonde, Jose
    Juez, Marina
    Alcocer, Jorge
    Boix, Ricardo
    Rueda, Cristina
    Martin, Ivan
    Tebar, Eduardo
    Palmero, Julio
    JOURNAL OF CARDIAC SURGERY, 2009, 24 (05) : 534 - 538