Quantitative studies on B-mode ultrasound and point shear wave elastography of kidneys in nonazotemic dogs

被引:0
|
作者
Jena, Biswadeep [1 ]
Mohindroo, Jitender [1 ]
Gupta, Kuldip [2 ]
Singh, Navdeep [1 ]
机构
[1] Guru Angad Dev Vet & Anim Sci Univ, Coll Vet Sci, Dept Vet Surg & Radiol, Ludhiana 141004, Punjab, India
[2] Guru Angad Dev Vet & Anim Sci Univ, Coll Vet Sci, Dept Vet Pathol, Ludhiana, Punjab, India
关键词
elastography; nonazotemic; substitute canine for dog; substitute renal for kidney; ultrasound; SYMMETRIC DIMETHYLARGININE; ULTRASONOGRAPHIC FEATURES; RENAL SIZE; DISEASE; PROTEINURIA; NEPHROPATHY; ASSOCIATION; DIAGNOSIS; VELOCITY; LENGTH;
D O I
10.1111/vru.13346
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Renal diseases in dogs can be diagnosed effectively using B-mode ultrasound. Point shear wave elastography (pSWE) has demonstrated usefulness in diagnosing renal diseases in human medicine. However, its application in veterinary medicine is in its nascent stage. It was hypothesized that establishing pSWE reference values in nonazotemic dogs would prove valuable in differentiating renal diseases. In light of this, a single-center, quantitative study with an objective to normalize B-mode ultrasound parameters and pSWE values of the kidney in nonazotemic dogs was conducted. A total of 198 animals presented with clinical signs of anorexia, vomiting, weight loss, and dehydration were enrolled in the study spanning 2 years. Among them, 52 nonazotemic dogs were included as subjects for the study. B-mode ultrasound quantitative parameters, including length (L), breadth (B), height (H), cortical thickness (RCT), and medulla thickness (RMT) of the kidneys, as well as the diameter of the aorta (Ao), were normalized. Additionally, calculated parameters such as L:Ao, B:Ao, H:Ao, RCT:Ao, and corticomedullary ratios were worked out. Point shear wave elastography values were obtained from the cranial and caudal poles of renal cortices using ElastPQ stiffness software. The pSWE values of kidneys in nonazotemic dogs were normalized. The mean +/- standard error values were 1.04 +/- 0.08 m/s (95% confidence interval: 0.88-1.19 m/s) and 4.18 +/- 0.62 kPa (95% confidence interval: 2.93-5.42 kPa). In conclusion, B-mode ultrasound quantitative parameters, ratios, and pSWE values were normalized in nonazotemic dogs, which may prove valuable in differentiating renal pathologies in canine patients.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [41] Differentiating the acute phase of gout from the intercritical phase with ultrasound and quantitative shear wave elastography
    Wang, Qiao
    Guo, Le-Hang
    Li, Xiao-Long
    Zhao, Chong-Ke
    Li, Ming-Xu
    Wang, Ling
    Liu, Xin-Ying
    Xu, Hui-Xiong
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5316 - 5327
  • [42] QUANTITATIVE ASSESSMENT OF SKIN STIFFNESS IN LOCALIZED SCLERODERMA USING ULTRASOUND SHEAR-WAVE ELASTOGRAPHY
    Wang, Liyun
    Yan, Feng
    Yang, Yujia
    Xiang, Xi
    Qiu, Li
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (07) : 1339 - 1347
  • [43] ULTRASOUND B-MODE IMAGING IN OBSERVATIONAL STUDIES OF ATHEROSCLEROTIC PROGRESSION
    SALONEN, JT
    SALONEN, R
    CIRCULATION, 1993, 87 (03) : 56 - 65
  • [44] Quantitative shear wave ultrasound elastography: initial experience in solid breast masses
    Evans, Andrew
    Whelehan, Patsy
    Thomson, Kim
    McLean, Denis
    Brauer, Katrin
    Purdie, Colin
    Jordan, Lee
    Baker, Lee
    Thompson, Alastair
    BREAST CANCER RESEARCH, 2010, 12 (06)
  • [45] B-mode and Doppler ultrasound of bitches' kidneys with mammary neoplasia submitted to adjuvant chemotherapy
    da Silva, Ligia O. Pinto
    Santos, Marcia Carolina S.
    Pina, Bianca F.
    Souza, Guilherme N.
    Ferreira, Maria de Lourdes G.
    PESQUISA VETERINARIA BRASILEIRA, 2023, 43
  • [46] Liver Fibrosis Assessment Using Transient Elastography Guided with Real-Time B-Mode Ultrasound Imaging
    Zheng, Yong-Ping
    Mak, Tak-Man
    Huang, Zheng-Ming
    Cheung, Chung-Wai James
    Zhou, Yong-Jin
    He, Jun-Feng
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1036 - 1039
  • [47] Fusion of Ultrasound B-Mode and Vibro-Elastography Images for Automatic 3-D Segmentation of the Prostate
    Mahdavi, S. Sara
    Moradi, Mehdi
    Morris, William J.
    Goldenberg, S. Larry
    Salcudean, Septimiu E.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (11) : 2073 - 2082
  • [48] Synthetic Elastography Using B-Mode Ultrasound Through a Deep Fully Convolutional Neural Network
    Wildeboer, R. R.
    van Sloun, R. J. G.
    Mannaerts, C. K.
    Moraes, P. H.
    Salomon, G.
    Chammas, M. C.
    Wijkstra, H.
    Mischi, M.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (12) : 2640 - 2648
  • [49] Quantitative breast mass classification based on the integration of B-mode features and strain features in elastography
    Lo, Chung-Ming
    Chang, Yeun-Chung
    Yang, Ya-Wen
    Huang, Chiun-Sheng
    Chang, Ruey-Feng
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 64 : 91 - 100
  • [50] Advantages of b-mode ultrasound combined with strain elastography in differentiation of idiopathic granulomatous mastitis from malignant breast lesions
    Arslan, Serdar
    Oncu, Fatih
    Eryilmaz, Mehmet Ali
    Durmaz, Mehmet Sedat
    Altunkeser, Aysegul
    Unlu, Yasar
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2018, 48 (01) : 16 - 23