Quantitative studies on B-mode ultrasound and point shear wave elastography of kidneys in nonazotemic dogs

被引:0
|
作者
Jena, Biswadeep [1 ]
Mohindroo, Jitender [1 ]
Gupta, Kuldip [2 ]
Singh, Navdeep [1 ]
机构
[1] Guru Angad Dev Vet & Anim Sci Univ, Coll Vet Sci, Dept Vet Surg & Radiol, Ludhiana 141004, Punjab, India
[2] Guru Angad Dev Vet & Anim Sci Univ, Coll Vet Sci, Dept Vet Pathol, Ludhiana, Punjab, India
关键词
elastography; nonazotemic; substitute canine for dog; substitute renal for kidney; ultrasound; SYMMETRIC DIMETHYLARGININE; ULTRASONOGRAPHIC FEATURES; RENAL SIZE; DISEASE; PROTEINURIA; NEPHROPATHY; ASSOCIATION; DIAGNOSIS; VELOCITY; LENGTH;
D O I
10.1111/vru.13346
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Renal diseases in dogs can be diagnosed effectively using B-mode ultrasound. Point shear wave elastography (pSWE) has demonstrated usefulness in diagnosing renal diseases in human medicine. However, its application in veterinary medicine is in its nascent stage. It was hypothesized that establishing pSWE reference values in nonazotemic dogs would prove valuable in differentiating renal diseases. In light of this, a single-center, quantitative study with an objective to normalize B-mode ultrasound parameters and pSWE values of the kidney in nonazotemic dogs was conducted. A total of 198 animals presented with clinical signs of anorexia, vomiting, weight loss, and dehydration were enrolled in the study spanning 2 years. Among them, 52 nonazotemic dogs were included as subjects for the study. B-mode ultrasound quantitative parameters, including length (L), breadth (B), height (H), cortical thickness (RCT), and medulla thickness (RMT) of the kidneys, as well as the diameter of the aorta (Ao), were normalized. Additionally, calculated parameters such as L:Ao, B:Ao, H:Ao, RCT:Ao, and corticomedullary ratios were worked out. Point shear wave elastography values were obtained from the cranial and caudal poles of renal cortices using ElastPQ stiffness software. The pSWE values of kidneys in nonazotemic dogs were normalized. The mean +/- standard error values were 1.04 +/- 0.08 m/s (95% confidence interval: 0.88-1.19 m/s) and 4.18 +/- 0.62 kPa (95% confidence interval: 2.93-5.42 kPa). In conclusion, B-mode ultrasound quantitative parameters, ratios, and pSWE values were normalized in nonazotemic dogs, which may prove valuable in differentiating renal pathologies in canine patients.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [21] Synthetic Elastography from B-Mode ultrasound through Deep Learning
    Wildeboer, R. R.
    van Sloun, R. J. G.
    Mannaerts, Christophe K.
    Salomon, G.
    Wijkstra, H.
    Mischi, M.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 108 - 110
  • [22] QUANTITATIVE ASSESSMENT OF KELOIDS USING ULTRASOUND SHEAR WAVE ELASTOGRAPHY
    Guo, Ruiqian
    Xiang, Xi
    Wang, Liyun
    Zhu, Bihui
    Cheng, Shan
    Qiu, Li
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (05): : 1169 - 1178
  • [23] Ultrasound in the Diagnosis of Non-Expandable Lung: A Prospective Observational Study of M-Mode, B-Mode, and 2D-Shear Wave Elastography
    Petersen, Jesper Koefod
    Fjaellegaard, Katrine
    Rasmussen, Daniel B.
    Alstrup, Gitte
    Hoegholm, Asbjorn
    Sidhu, Jatinder Singh
    Sivapalan, Pradeesh
    Gerke, Oke
    Bhatnagar, Rahul
    Clementsen, Paul Frost
    Laursen, Christian B.
    Bodtger, Uffe
    Martini, Chiara
    Perini, Paolo
    DIAGNOSTICS, 2024, 14 (02)
  • [24] Reliability of B-mode ultrasound and shear wave elastography in evaluating sacral bone and soft tissue characteristics in young adults with clinical feasibility in elderly
    Abou Karam, Maher
    Mukhina, Ekaterina
    Daras, Nils
    Rivals, Isabelle
    Pillet, Helene
    Skalli, Wafa
    Connesson, Nathanael
    Payan, Yohan
    Rohan, Pierre-Yves
    JOURNAL OF TISSUE VIABILITY, 2022, 31 (02) : 245 - 254
  • [25] COMPARISON OF STRAIN AND SHEAR WAVE ELASTOGRAPHY FOR THE DIFFERENTIATION OF BENIGN FROM MALIGNANT BREAST LESIONS, COMBINED WITH B-MODE ULTRASONOGRAPHY: QUALITATIVE AND QUANTITATIVE ASSESSMENTS
    Youk, Ji Hyun
    Son, Eun Ju
    Gweon, Hye Mi
    Kim, Hana
    Park, Yun Joo
    Kim, Jeong-Ah
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (10): : 2336 - 2344
  • [26] Applicability of B-mode ultrasonography, ARFI elastography and contrast-enhanced ultrasound in the evaluation of chronic kidney disease in dogs1
    da Cruz, Igor C. K.
    Gasser, Beatriz
    Maronezi, Marjury Cristina
    Uscategui, Ricardo Andres R.
    Feliciano, Marcus Antonio R.
    Padilha-Nakaghi, Luciana Cristina
    Aires, Luiz Paulo N.
    da Silva, Priscila D. A.
    PESQUISA VETERINARIA BRASILEIRA, 2021, 41
  • [27] Binary classification of non-specific low back pain condition based on the combination of B-mode ultrasound and shear wave elastography at multiple sites
    Yu, Xiaocheng
    Xu, Xiaohua
    Huang, Qinghua
    Zhu, Guowen
    Xu, Faying
    Liu, Zhenhua
    Su, Lin
    Zheng, Haiping
    Zhou, Chen
    Chen, Qiuming
    Gao, Fen
    Lin, Mengting
    Yang, Shuai
    Chiang, Mou-Hsun
    Zhou, Yongjin
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [28] A Prospective Two Center Study Comparing Breast Cancer Lesion Size Defined by 2D Shear Wave Elastography, B-Mode Ultrasound, and Mammography with the Histopathological Size
    Farrokh, Andre
    Treu, Linn
    Ohlinger, Ralf
    Flieger, Carolin
    Maass, Nicolai
    Schaefer, Fritz K. W.
    ULTRASCHALL IN DER MEDIZIN, 2019, 40 (02): : 212 - 220
  • [29] ULTRASOUND AND CT REGISTRATION QUALITY: ELASTOGRAPHY VS. CLASSICAL B-MODE
    Keil, Matthias
    Stolka, Philipp J.
    Wiebel, Marion
    Sakas, Georgios
    McVeigh, Elliot R.
    Taylor, Russell H.
    Boctor, Emad
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 967 - +
  • [30] Quantitative Assessment of Tendon Backscatter Anisotropy in B-Mode Ultrasound
    Gao, Jing
    Rosander, Ashley
    Rubin, Jonathan M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (06): : 1408 - 1414