Quantitative studies on B-mode ultrasound and point shear wave elastography of kidneys in nonazotemic dogs

被引:0
|
作者
Jena, Biswadeep [1 ]
Mohindroo, Jitender [1 ]
Gupta, Kuldip [2 ]
Singh, Navdeep [1 ]
机构
[1] Guru Angad Dev Vet & Anim Sci Univ, Coll Vet Sci, Dept Vet Surg & Radiol, Ludhiana 141004, Punjab, India
[2] Guru Angad Dev Vet & Anim Sci Univ, Coll Vet Sci, Dept Vet Pathol, Ludhiana, Punjab, India
关键词
elastography; nonazotemic; substitute canine for dog; substitute renal for kidney; ultrasound; SYMMETRIC DIMETHYLARGININE; ULTRASONOGRAPHIC FEATURES; RENAL SIZE; DISEASE; PROTEINURIA; NEPHROPATHY; ASSOCIATION; DIAGNOSIS; VELOCITY; LENGTH;
D O I
10.1111/vru.13346
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Renal diseases in dogs can be diagnosed effectively using B-mode ultrasound. Point shear wave elastography (pSWE) has demonstrated usefulness in diagnosing renal diseases in human medicine. However, its application in veterinary medicine is in its nascent stage. It was hypothesized that establishing pSWE reference values in nonazotemic dogs would prove valuable in differentiating renal diseases. In light of this, a single-center, quantitative study with an objective to normalize B-mode ultrasound parameters and pSWE values of the kidney in nonazotemic dogs was conducted. A total of 198 animals presented with clinical signs of anorexia, vomiting, weight loss, and dehydration were enrolled in the study spanning 2 years. Among them, 52 nonazotemic dogs were included as subjects for the study. B-mode ultrasound quantitative parameters, including length (L), breadth (B), height (H), cortical thickness (RCT), and medulla thickness (RMT) of the kidneys, as well as the diameter of the aorta (Ao), were normalized. Additionally, calculated parameters such as L:Ao, B:Ao, H:Ao, RCT:Ao, and corticomedullary ratios were worked out. Point shear wave elastography values were obtained from the cranial and caudal poles of renal cortices using ElastPQ stiffness software. The pSWE values of kidneys in nonazotemic dogs were normalized. The mean +/- standard error values were 1.04 +/- 0.08 m/s (95% confidence interval: 0.88-1.19 m/s) and 4.18 +/- 0.62 kPa (95% confidence interval: 2.93-5.42 kPa). In conclusion, B-mode ultrasound quantitative parameters, ratios, and pSWE values were normalized in nonazotemic dogs, which may prove valuable in differentiating renal pathologies in canine patients.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [1] Criteria for evaluation of kidneys by B-mode ultrasound in dogs and cats: A current state of knowledge
    Gruss, Michal
    Szygula, Aleksandra
    Czyzewska-Dors, Ewelina
    Pomorska-Mol, Malgorzata
    MEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICE, 2024, 80 (07): : 313 - 318
  • [2] Application of intraoperative B-mode ultrasound and shear wave elastography for glioma grading
    Yin, Lu
    Cheng, Linggang
    Wang, Fumin
    Zhu, Xueli
    Hua, Yue
    He, Wen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (06) : 2733 - 2743
  • [3] Measurement of Shear Wave Velocity for Elastography Using Conventional B-mode Scan of Focused Ultrasound
    Qu, Zhen
    Ono, Yuu
    2017 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2017, : 129 - 133
  • [4] A comparative evaluation of cataract classifications based on shear-wave elastography and B-mode ultrasound findings
    Ozgokce, Mesut
    Batur, Muhammed
    Alpaslan, Muhammed
    Yavuz, Alpaslan
    Batur, Abdussamet
    Seven, Erbil
    Arslan, Harun
    JOURNAL OF ULTRASOUND, 2019, 22 (04) : 447 - 452
  • [5] A comparative evaluation of cataract classifications based on shear-wave elastography and B-mode ultrasound findings
    Mesut Ozgokce
    Muhammed Batur
    Muhammed Alpaslan
    Alpaslan Yavuz
    Abdussamet Batur
    Erbil Seven
    Harun Arslan
    Journal of Ultrasound, 2019, 22 : 447 - 452
  • [6] Breast-lesion Segmentation Combining B-Mode and Elastography Ultrasound
    Pons, Gerard
    Marti, Joan
    Marti, Robert
    Ganau, Sergi
    Noble, J. Alison
    ULTRASONIC IMAGING, 2016, 38 (03) : 209 - 224
  • [7] Multisample Ultrasound Point Shear Wave Elastography of the Liver Repeatability and Agreement With Conventional Point Shear Wave Elastography
    Dillman, Jonathan R.
    Trout, Andrew T.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (12) : 2749 - 2756
  • [8] Differentiation of benign and metastatic axillary lymph nodes in breast cancer: additive value of shear wave elastography to B-mode ultrasound
    Seo, Mirinae
    Sohn, Yu-Mee
    CLINICAL IMAGING, 2018, 50 : 258 - 263
  • [9] Fusion of B-mode and shear wave elastography ultrasound features for automated detection of axillary lymph node metastasis in breast carcinoma
    Pham, The-Hanh
    Faust, Oliver
    Koh, Joel En Wei
    Ciaccio, Edward J.
    Barua, Prabal D.
    Omar, Norlia
    Ng, Wei Lin
    Ab Mumin, Nazimah
    Rahmat, Kartini
    Acharya, U. Rajendra
    EXPERT SYSTEMS, 2022, 39 (05)
  • [10] B-mode ultrasound to elastography synthesis using multiscale learning
    Dai, Fei
    Li, Yifang
    Zhu, Yunkai
    Li, Boyi
    Shi, Qinzhen
    Chen, Yaqing
    Ta, Dean
    ULTRASONICS, 2024, 138