Validation of Mitra® VAMS® as a blood collection technique for trace elements analysis using ICP-MS/MS

被引:2
作者
Breton, Anthony [1 ,2 ]
Cirtiu, Ciprian Mihai [1 ,2 ]
Muehlethaler, Cyril [2 ]
Rudge, James [3 ]
Fleury, Normand [1 ]
机构
[1] Inst Natl Sante Publ Quebec INSPQ, Ctr Toxicol Quebec CTQ, 945 Wolfe, Quebec City, PQ G1V 5B3, Canada
[2] Univ Quebec Trois Rivieres UQTR, Dept Chem Biochem & Phys, 3351 Boul Forges, Quebec City, PQ G9A 5H7, Canada
[3] Crownhill Business Ctr, Trajan Sci & Med, 14 Vincent Ave, Milton Keynes MK8 0AB, England
关键词
ICP-MS/MS; Method development and validation; Trace elements; VAMS; volumetric absorptive microsampling; whole blood; WHOLE-BLOOD; MICROSAMPLING TECHNIQUES; METABOLOMICS; PLASMA; METAL;
D O I
10.4155/bio-2023-0180
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Clinical dosage of toxic and essential elements in blood is well established and the collection method is still by venipuncture. This method has drawbacks and is not suited for everyone. Volumetric absorptive microsampling (VAMS) has been shown to have advantages over venipuncture. Materials & methods: Using inductively coupled plasma tandem mass spectrometry, a method for quantifying elements in whole blood sampled on VAMS was developed/validated. Method's performance was assessed by comparison with whole blood results. Results: Validation and performance assessment tests tend to show that most of the targeted elements provides accurate and reproducible results comparing to a method of reference. Conclusion: Overall, VAMS presents good preliminary results to eventually become an alternative to venipuncture for blood sampling for some trace elements analysis purposes.
引用
收藏
页码:203 / 217
页数:16
相关论文
共 39 条
  • [1] ABDULLA M, 1990, BIOL TRACE ELEM RES, V23, P25, DOI 10.1007/BF02917176
  • [2] Determination of ultra-trace amounts of prosthesis-related metals in whole blood using volumetric absorptive micro-sampling and tandem ICP - Mass spectrometry
    Bolea-Fernandez, Eduardo
    Phan, Kim
    Balcaen, Lieve
    Resano, Martin
    Vanhaecke, Frank
    [J]. ANALYTICA CHIMICA ACTA, 2016, 941 : 1 - 9
  • [3] Method development for the quantification of lead levels in whole blood sampled on Mitra(R) with VAMS(R) tips by inductively coupled plasma-MS/MS
    Breton, Anthony
    Cirtiu, Ciprian Mihai
    Fleury, Normand
    Lajeunesse, Andre
    Rudge, James
    [J]. BIOANALYSIS, 2023, 15 (02) : 71 - 81
  • [4] Comparative study on microsampling techniques in metabolic fingerprinting studies applying gas chromatography-MS analysis
    Cala, Monica P.
    Meesters, Roland J. W.
    [J]. BIOANALYSIS, 2017, 9 (17) : 1329 - 1340
  • [5] Analysis of whole blood by ICP-MS equipped with a high temperature total sample consumption system
    Canabate, Agueda
    Garcia-Ruiz, Esperanza
    Resano, Martin
    Todoli, Jose-Luis
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (01) : 78 - 87
  • [6] Development, validation and application of an inductively coupled plasma - mass spectrometry method to determine cobalt in metal-on-metal prosthesis patients using volumetric absorptive microsampling
    Capiau, Sara
    Bolea-Fernandez, Eduardo
    Balcaen, Lieve
    Van Der Straeten, Catherine
    Verstraete, Alain G.
    Vanhaecke, Frank
    Stove, Christophe P.
    [J]. TALANTA, 2020, 208
  • [7] Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach
    Carignan, Courtney C.
    Bauer, Rachel A.
    Patterson, Andrew
    Phomsopha, Thep
    Redman, Eric
    Stapleton, Heather M.
    Higgins, Christopher P.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (21) : 7950 - 7957
  • [8] CAWTE J, 1987, LANCET, V1, P1257
  • [9] Dart RC., 2004, MED TOXICOL, P1796
  • [10] Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study
    De Kesel, Pieter M. M.
    Lambert, Willy E.
    Stove, Christophe P.
    [J]. ANALYTICA CHIMICA ACTA, 2015, 881 : 65 - 73