Physical parameters influence the microbial quality of indoor air in research laboratories: A report from Malaysia

被引:2
作者
Yogeswaran, Kuilan [1 ,2 ]
Azmi, Liyana [3 ]
Bhassu, Subha [1 ]
Isa, Hafizah N. [4 ]
Aziz, Muhamad Afiq [1 ]
机构
[1] Univ Malaya, Fac Sci, Inst Biol Sci, Kuala Lumpur 50603, Malaysia
[2] Natl Pharmaceut Regulatory Agcy NPRA, Minist Hlth, Lot 36,Jalan Prof Diraja Ungku Aziz, Petaling Jaya 46200, Selangor, Malaysia
[3] Univ Sains Islam Malaysia, Fac Med & Hlth Sci, Nilai 71800, Negeri Sembilan, Malaysia
[4] Int Islamic Univ Malaysia, Dept Phys, Kulliyah Sci, Jalan Sultan Ahmad Shah, Kuantan 25200, Pahang, Malaysia
关键词
Bacteria; Fungi; Environment; Indoor air quality (IAQ); Laboratories; Ventilation; SCHOOLS; COMMUNITIES;
D O I
10.1016/j.kjs.2023.04.009
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The quality of air conditioning and ventilation systems in laboratories is vital to ensure optimum health of the users and guarantee the accuracy of experiments conducted. Moreover, recent studies show that the average quality of air conditioning and ventilation systems in labs can pose health risks to occupants. The study aims to examine the relationship between physical parameters and microbial pollutants in research laboratories' indoor air quality (IAQ) by quantifying and characterising the bacteria and fungi in the indoor environment of research laboratories using the settle plate method; whereby our Petri dishes containing media are exposed to the air for sample collection. This study was conducted over the course of 3 day at three different research laboratories: Virology Lab (VL), Genetic Lab (GL), and Aquatic Lab (AL). The physical parameters such as air temperature, humidity and carbon dioxide were measured using FLUKE 975 air meter, whereas the microbial parameters were assessed using the settle plate method with Tryptone Soya agar and Sabouraud Dextrose agar for the bacterial and fungal count, respectively. Our results showed that the high temperature and relative humidity, exceeded the standard threshold for temperature (23-26 degrees C) and relative humidity (40-70%) set by the Department of Occupational Safety and Health (DOSH). Additionally, because of poor air conditioning and ventilation system maintenance, there were high total bacterial counts in GL (CFU/m3 234.34 +/- 30.93) and total fungal counts in VL (CFU/m3 589.34 +/- 53.03). We also showed that the most commonly isolated bacteria and fungi in research laboratories were Staphylococcus spp. (72.2%) and Cladosporium spp. (76.7%). In conclusion, we reported that there was a correlation between the physical parameters and microbial pollutants in the research laboratories. Therefore, regular monitoring of indoor air quality (IAQ) parameters and maintenance of the air conditioning and ventilation system should be carried out to ensure a good and safe indoor environment in research laboratories.
引用
收藏
页码:665 / 673
页数:9
相关论文
共 50 条
[41]   Influence of Binders and Lightweight Aggregates on the Properties of Cementitious Mortars: From Traditional Requirements to Indoor Air Quality Improvement [J].
Giosue, Chiara ;
Pierpaoli, Mattia ;
Mobili, Alessandra ;
Ruello, Maria Letizia ;
Tittarelli, Francesca .
MATERIALS, 2017, 10 (08)
[42]   Reliability of the Results from Unplanned Subjective Assessment of the Indoor Air Quality and Thermal Comfort Parameters in Small Lecture Room [J].
Ivanov, Martin .
EENVIRO-YRC 2015 - BUCHAREST, 2016, 85 :295-302
[43]   Research on the building indoor air quality's functional classification and its changing prediction [J].
Yuan, J ;
Han, JH ;
Xie, XD .
BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, :122-126
[44]   Indoor Air Quality in Urban India: Current Status, Research Gap, and the Way Forward [J].
Thakur, Alok Kumar ;
Patel, Sameer .
ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2023, 10 (12) :1146-1158
[45]   The short-term effect of residential home energy retrofits on indoor air quality and microbial exposure: A case-control study [J].
Nguyen, Mytien ;
Holmes, Eric C. ;
Angenent, Largus T. .
PLOS ONE, 2021, 16 (09)
[46]   Prediction of Concentration Change and Influence Analysis of Indoor/Outdoor in Subway Station using Indoor Air Quality Monitoring Data [J].
Kim, Jong Bum ;
Park, Sechan ;
Lee, Yongil ;
Lee, Seonyeop ;
Kim, Jeongho ;
Park, Duckshin .
JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2022, 38 (01) :30-45
[47]   Novel insights into indoor air purification capability of microalgae: characterization using multiple air quality parameters and comparison with common methods [J].
Wang, Qiao ;
Li, Lihua ;
Hong, Yu ;
Zhai, Qingyu ;
He, Yitian .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (17) :49829-49839
[48]   Electrospun Fibers from Biobased and Recycled Materials for Indoor Air Quality Enhancement [J].
Czerwinska, Natalia ;
Giosue, Chiara ;
Generosi, Nicola ;
Pierpaoli, Mattia ;
Jbr, Rida ;
Luzi, Francesca ;
Corinaldesi, Valeria ;
Ruello, Maria Letizia .
MOLECULES, 2025, 30 (06)
[49]   Research Study on Indoor Air Quality (IAQ) inside of the Subway Cabin in Seoul Metropolitan City [J].
Lee, Kyoung Bin ;
Kim, Jin Sik ;
Bae, Sung Joon ;
Kim, Shin Do .
JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2014, 30 (02) :175-187
[50]   Scientific production on indoor air quality of environments used for physical exercise and sports practice: Bibliometric analysis [J].
Andrade, Alexandro ;
Dominski, Fabio Hech ;
Coimbra, Danilo Reis .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2017, 196 :188-200