Physical parameters influence the microbial quality of indoor air in research laboratories: A report from Malaysia

被引:2
作者
Yogeswaran, Kuilan [1 ,2 ]
Azmi, Liyana [3 ]
Bhassu, Subha [1 ]
Isa, Hafizah N. [4 ]
Aziz, Muhamad Afiq [1 ]
机构
[1] Univ Malaya, Fac Sci, Inst Biol Sci, Kuala Lumpur 50603, Malaysia
[2] Natl Pharmaceut Regulatory Agcy NPRA, Minist Hlth, Lot 36,Jalan Prof Diraja Ungku Aziz, Petaling Jaya 46200, Selangor, Malaysia
[3] Univ Sains Islam Malaysia, Fac Med & Hlth Sci, Nilai 71800, Negeri Sembilan, Malaysia
[4] Int Islamic Univ Malaysia, Dept Phys, Kulliyah Sci, Jalan Sultan Ahmad Shah, Kuantan 25200, Pahang, Malaysia
关键词
Bacteria; Fungi; Environment; Indoor air quality (IAQ); Laboratories; Ventilation; SCHOOLS; COMMUNITIES;
D O I
10.1016/j.kjs.2023.04.009
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The quality of air conditioning and ventilation systems in laboratories is vital to ensure optimum health of the users and guarantee the accuracy of experiments conducted. Moreover, recent studies show that the average quality of air conditioning and ventilation systems in labs can pose health risks to occupants. The study aims to examine the relationship between physical parameters and microbial pollutants in research laboratories' indoor air quality (IAQ) by quantifying and characterising the bacteria and fungi in the indoor environment of research laboratories using the settle plate method; whereby our Petri dishes containing media are exposed to the air for sample collection. This study was conducted over the course of 3 day at three different research laboratories: Virology Lab (VL), Genetic Lab (GL), and Aquatic Lab (AL). The physical parameters such as air temperature, humidity and carbon dioxide were measured using FLUKE 975 air meter, whereas the microbial parameters were assessed using the settle plate method with Tryptone Soya agar and Sabouraud Dextrose agar for the bacterial and fungal count, respectively. Our results showed that the high temperature and relative humidity, exceeded the standard threshold for temperature (23-26 degrees C) and relative humidity (40-70%) set by the Department of Occupational Safety and Health (DOSH). Additionally, because of poor air conditioning and ventilation system maintenance, there were high total bacterial counts in GL (CFU/m3 234.34 +/- 30.93) and total fungal counts in VL (CFU/m3 589.34 +/- 53.03). We also showed that the most commonly isolated bacteria and fungi in research laboratories were Staphylococcus spp. (72.2%) and Cladosporium spp. (76.7%). In conclusion, we reported that there was a correlation between the physical parameters and microbial pollutants in the research laboratories. Therefore, regular monitoring of indoor air quality (IAQ) parameters and maintenance of the air conditioning and ventilation system should be carried out to ensure a good and safe indoor environment in research laboratories.
引用
收藏
页码:665 / 673
页数:9
相关论文
共 50 条
  • [31] Review of research on air-conditioning systems and indoor air quality control for human health
    Yu, B. F.
    Hu, Z. B.
    Liu, M.
    Yang, H. L.
    Kong, Q. X.
    Liu, Y. H.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (01): : 3 - 20
  • [32] Assessment of Indoor Air Quality in Schools from Anatolia, Turkey
    Babaoglu, Ulken Tunga
    Ogutcu, Hatice
    Erdogdu, Makbule
    Taskiran, Funda
    Gullu, Gulen
    Oymak, Sibel
    POLLUTION, 2022, 8 (01): : 57 - 67
  • [33] Indoor air pollution, physical and comfort parameters related to schoolchildren's health: Data from the European SINPHONIE study
    Baloch, Ramen Munir
    Maesano, Cara Nichole
    Christoffersen, Jens
    Banerjee, Soutrik
    Gabriel, Marta
    Csobod, Eva
    Fernandes, Eduardo de Oliveira
    Annesi-Maesano, Isabella
    Csobod, Eva
    Szuppinger, Peter
    Prokai, Reka
    Farkas, Petur
    Fuzi, Cecilia
    Cani, Eduart
    Draganic, Jasna
    Mogyorosy, Eszter Reka
    Korac, Zorica
    Ventura, Gabriela
    Madureira, Joana
    Paciencia, Ines
    Martins, Anabela
    Pereira, Ricardo
    Ramos, Elisabete
    Rudnai, Peter
    Paldy, Anna
    Dura, Gyula
    Beregszaszi, Timea
    Vaskovi, Eva
    Magyar, Donat
    Pandics, Tamas
    Remeny-Nagy, Zsuzsanna
    Szentmihalyi, Renata
    Udvardy, Orsolya
    Varro, Mihaly J.
    Kephalopoulos, Stylianos
    Kotzias, Dimitrios
    Barrero-Moreno, Josefa
    Mehmeti, Rahmije
    Vilic, Aida
    Maestro, Daniel
    Moshammer, Hanns
    Strasser, Gabriela
    Brigitte, Piegler
    Hohenblum, Philipp
    Goelen, Eddy
    Stranger, Marianne
    Spruy, Maarten
    Sidjimov, Momchil
    Hadjipanayis, Adamos
    Katsonouri-Sazeides, Andromachi
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 739
  • [34] Microbial Indoor Air Quality and Associated Factors in Jimma Town Prison Administration, Southwestern Ethiopia
    Ahmednur, Mahmud
    Awel, Hanan
    Haile, Gutama
    ENVIRONMENTAL HEALTH INSIGHTS, 2022, 16
  • [35] Microbial Indoor Air Quality and Associated Factors in Jimma Town Prison Administration, Southwestern Ethiopia
    Ahmednur, Mahmud
    Awel, Hanan
    Haile, Gutama
    ENVIRONMENTAL HEALTH INSIGHTS, 2022, 16
  • [36] Statistical analysis of parameters influencing the relationship between outdoor and indoor air quality in schools
    Poupard, O
    Blondeau, P
    Iordache, V
    Allard, F
    ATMOSPHERIC ENVIRONMENT, 2005, 39 (11) : 2071 - 2080
  • [37] Effects of PM, TVOCs and comfort parameters on indoor air quality of residences with young children
    Stamatelopoulou, A.
    Asimakopoulos, D. N.
    Maggos, T.
    BUILDING AND ENVIRONMENT, 2019, 150 : 233 - 244
  • [38] Indoor air quality in kindergartens: the relationship between environmental parameters and levels of occupation of spaces
    Santos, Joana
    Aguiar, Mafalda
    Carvalhais, Carlos
    Pereira, Cristiana
    Fernandes, Anabela
    Silva, Manuela
    Baptista, Joao
    Teixeira, Joao
    SHO2011: INTERNATIONAL SYMPOSIUM ON OCCUPATIONAL SAFETY AND HYGIENE, 2011, : 582 - 587
  • [39] Pilot Study on the Physical, Chemical, and Biological Determinants of Indoor Air Quality in University Classrooms
    Edelmers, Edgars
    Kauce, Ruta
    Konopecka, Vita
    Veignere, Elizabete
    Sprudza, Klinta Luize
    Nelke, Valters
    Citskovska, Elizabete
    Sipilova, Viktorija
    Cikuts, Matiss
    Skrebele, Elizabete
    Skadins, Ingus
    Martinsone, Zanna
    Borodinecs, Anatolijs
    ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, 2023, 27 (01) : 753 - 762
  • [40] Assessment and characterization of bioaerosols from an indoor environment-operated wastewater management facility: unraveling pathogenicity in research laboratories
    Singh, Nitin Kumar
    Sanghvi, Gaurav
    Yadav, Manish
    Padhiyar, Hirendrasinh
    Gupta, Abhishek
    Christian, Johnson
    Thanki, Arti
    AEROBIOLOGIA, 2022, 38 (04) : 519 - 531