Physical parameters influence the microbial quality of indoor air in research laboratories: A report from Malaysia

被引:2
|
作者
Yogeswaran, Kuilan [1 ,2 ]
Azmi, Liyana [3 ]
Bhassu, Subha [1 ]
Isa, Hafizah N. [4 ]
Aziz, Muhamad Afiq [1 ]
机构
[1] Univ Malaya, Fac Sci, Inst Biol Sci, Kuala Lumpur 50603, Malaysia
[2] Natl Pharmaceut Regulatory Agcy NPRA, Minist Hlth, Lot 36,Jalan Prof Diraja Ungku Aziz, Petaling Jaya 46200, Selangor, Malaysia
[3] Univ Sains Islam Malaysia, Fac Med & Hlth Sci, Nilai 71800, Negeri Sembilan, Malaysia
[4] Int Islamic Univ Malaysia, Dept Phys, Kulliyah Sci, Jalan Sultan Ahmad Shah, Kuantan 25200, Pahang, Malaysia
关键词
Bacteria; Fungi; Environment; Indoor air quality (IAQ); Laboratories; Ventilation; SCHOOLS; COMMUNITIES;
D O I
10.1016/j.kjs.2023.04.009
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The quality of air conditioning and ventilation systems in laboratories is vital to ensure optimum health of the users and guarantee the accuracy of experiments conducted. Moreover, recent studies show that the average quality of air conditioning and ventilation systems in labs can pose health risks to occupants. The study aims to examine the relationship between physical parameters and microbial pollutants in research laboratories' indoor air quality (IAQ) by quantifying and characterising the bacteria and fungi in the indoor environment of research laboratories using the settle plate method; whereby our Petri dishes containing media are exposed to the air for sample collection. This study was conducted over the course of 3 day at three different research laboratories: Virology Lab (VL), Genetic Lab (GL), and Aquatic Lab (AL). The physical parameters such as air temperature, humidity and carbon dioxide were measured using FLUKE 975 air meter, whereas the microbial parameters were assessed using the settle plate method with Tryptone Soya agar and Sabouraud Dextrose agar for the bacterial and fungal count, respectively. Our results showed that the high temperature and relative humidity, exceeded the standard threshold for temperature (23-26 degrees C) and relative humidity (40-70%) set by the Department of Occupational Safety and Health (DOSH). Additionally, because of poor air conditioning and ventilation system maintenance, there were high total bacterial counts in GL (CFU/m3 234.34 +/- 30.93) and total fungal counts in VL (CFU/m3 589.34 +/- 53.03). We also showed that the most commonly isolated bacteria and fungi in research laboratories were Staphylococcus spp. (72.2%) and Cladosporium spp. (76.7%). In conclusion, we reported that there was a correlation between the physical parameters and microbial pollutants in the research laboratories. Therefore, regular monitoring of indoor air quality (IAQ) parameters and maintenance of the air conditioning and ventilation system should be carried out to ensure a good and safe indoor environment in research laboratories.
引用
收藏
页码:665 / 673
页数:9
相关论文
共 50 条
  • [1] LABORATORY FACILITY DESIGN AND MICROBIAL INDOOR AIR QUALITY IN SELECTED HOSPITAL LABORATORIES
    Luksamijarulkul, Pipat
    Kiennukul, Nuchanard
    Vatthanasomboon, Pisit
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2014, 45 (03) : 746 - 755
  • [2] Indoor Environmental Parameters: Considering Measures of Microbial Ecology in the Characterization of Indoor Air Quality
    Mankiewicz, Phoebe
    Ciardullo, Christina
    Theodoridis, Andreas
    Henaff, Elizabeth
    Dyson, Anna
    INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,
  • [3] Bioaerosol levels and the indoor air quality of laboratories in Bangkok metropolis
    Kraiwuth Kallawicha
    H. Jasmine Chao
    Natkrita Kotchasatan
    Aerobiologia, 2019, 35 : 1 - 14
  • [4] Bioaerosol levels and the indoor air quality of laboratories in Bangkok metropolis
    Kallawicha, Kraiwuth
    Chao, H. Jasmine
    Kotchasatan, Natkrita
    AEROBIOLOGIA, 2019, 35 (01) : 1 - 14
  • [5] Indoor air quality (IAQ) characteristics and its microbial community identifications at two selected schools in Pahang, Malaysia: a preliminary study
    Hizrri, A.
    Nabilah, Zati M. G.
    Amni, Nurul Z.
    Shahida, N.
    Maryam, Z.
    Hazrin, A. H.
    Faez, Mohd S.
    Shukri, Mohd M. A.
    ASIAN JOURNAL OF AGRICULTURE AND BIOLOGY, 2018, 6 : 88 - 96
  • [6] Measurement of Indoor Air Quality Parameters in Daycare Centres in Kuala Lumpur Malaysia
    Cionita, Tezara
    Adam, Nor Mariah
    Jalaludin, Juliana
    Mansor, Mariani
    Siregar, Januar Parlaungan
    ADVANCES IN MECHANICAL AND MANUFACTURING ENGINEERING, 2014, 564 : 245 - +
  • [7] Compliance of Indoor Air Contaminants within the Main Prayer Halls of Mosques in Malacca with Malaysia's Indoor Air Quality Standard
    Rasli, Nur Baitul Izati
    Ismail, Mohd Rodzi
    Ramli, Nor Azam
    Shith, Syabiha
    Nazir, Amni Umirah Mohamad
    Yusof, Noor Faizah Fitri Md
    Zainordin, Nazatul Syadia
    JOURNAL OF CONSTRUCTION IN DEVELOPING COUNTRIES, 2019, 24 (02) : 105 - 121
  • [8] Impact of physical and microbiological parameters on proper indoor air quality in nursery
    Basinska, Malgorzata
    Michalkiewicz, Michal
    Ratajczak, Katarzyna
    ENVIRONMENT INTERNATIONAL, 2019, 132
  • [9] Attempt to improve indoor air quality in computer laboratories
    Telejko, Marek
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 1154 - 1160
  • [10] INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY CHARACTERISTICS AT SELECTED LIBRARIES IN PAHANG
    Hizrri, A.
    Khadijah, H.
    Hadry, Noor Faizul N.
    Norhidayah, A.
    Shukri, Mohd M. A.
    JURNAL TEKNOLOGI, 2015, 77 (24): : 51 - 56