Sonographic evaluation of median nerve cross-sectional area in a normal Iranian population: A cross-sectional study

被引:1
作者
Rayegani, Seyed Mansoor [1 ]
Bayat, Masume [1 ,2 ]
机构
[1] Shahid Beheshti Univ Med Sci, Phys Med & Rehabil Res Ctr, Tehran, Iran
[2] Imam Hossein Hosp, Shahid Madani St, Tehran, Iran
关键词
cross-sectional area; median nerve; reference values; ultrasonography; CARPAL-TUNNEL-SYNDROME; REFERENCE VALUES; DIAGNOSTIC-VALUE; WRIST RATIO; ULTRASONOGRAPHY; ASSOCIATION; SEVERITY;
D O I
10.1002/hsr2.1393
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
IntroductionConsidering disagreements on the normal range of median nerve cross-sectional area (MNCSA) and insufficient data in the Iranian population, this study aimed to measure normal MNCSA. MethodsIn this cross-sectional study, bilateral upper limbs of 99 subjects were assessed by sonography, and MNCSA was measured at three levels: forearm, carpal tunnel inlet (CTI), and carpal tunnel outlet (CTO). The association between MNCSA and demographic factors was assessed. ResultsMean MNCSA was 6.33 mm(2) at the forearm, 9.41 mm(2) at CTI, and 10.67 mm(2) at CTO. MNCSA was significantly higher in males (6.78 vs. 5.94 mm(2) at the forearm, 9.98 vs. 8.92 mm(2) at CTI, and 11.24 vs. 10.84 mm(2) at CTO in males and females, respectively) and taller (>170 cm) subjects in all three levels (6.69 vs. 6.03 mm(2) at the forearm, 9.80 vs. 9.02 mm(2) at CTI, and 11.27 vs. 10.12 mm(2) at CTO in taller and shorter subjects, respectively). MNCSA was not significantly associated with wrist ratio (WR) or body mass index (BMI). ConclusionThe normal MNCSA range in the Iranian population is 6.31 mm(2) (forearm) to 10.74 mm(2) (CTO). MNCSA is significantly higher in males and taller subjects but is not associated with BMI and WR.
引用
收藏
页数:6
相关论文
共 35 条
[1]   Cross-sectional area reference values for high-resolution ultrasonography of the upper extremity nerves in healthy Asian adults [J].
Bae, Dae Woong ;
An, Jae Young .
MEDICINE, 2021, 100 (18) :E25812
[2]   NORMAL VALUES OF MEDIAN NERVE CROSS-SECTIONAL AREA OBTAINED BY ULTRASOUND ALONG ITS COURSE IN THE ARM WITH ELECTROPHYSIOLOGICAL CORRELATIONS, IN 100 ASIAN SUBJECTS [J].
Bathala, Lokesh ;
Kumar, Pavan ;
Kumar, Krishna ;
Shaik, Ahammad Basha ;
Visser, Leo H. .
MUSCLE & NERVE, 2014, 49 (02) :284-286
[3]   Diagnostic Value of Ultrasound for Detecting Carpal Tunnel Syndrome in Patients With Rheumatoid Arthritis: A Three-Arm Cross-Sectional Study [J].
Bayat, Masume ;
Bagheri, Zohreh ;
Raeissadat, Seyed Ahmad ;
Rayegani, Seyed Mansoor ;
Ahmadzadeh, Arman ;
Shirani, Fatemeh .
JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2022, 38 (05) :411-418
[4]   Estimation of ultrasound reference values for the upper limb peripheral nerves in adults A cross-sectional study [J].
Bedewi, Mohamed Abdelmohsen ;
Abodonya, Ahmed ;
Kotb, Mamdouh ;
Mahmoud, Gehan ;
Kamal, Sanaa ;
Alqabbani, Abdullah ;
Alhariqi, Bader ;
Alanazy, Mohammed H. ;
Aldossari, Khaled ;
Swify, Sherine ;
Al-Bader, Fahad .
MEDICINE, 2017, 96 (50)
[5]   Nerve cross-sectional area in extremes of age [J].
Cartwright, Michael S. ;
Mayans, David R. ;
Gillson, Natalie A. ;
Griffin, Leah P. ;
Walker, Francis O. .
MUSCLE & NERVE, 2013, 47 (06) :890-893
[6]   Ultrasonographic measurement of median nerve cross-sectional area reference values in a healthy Han population from Guiyang, China [J].
Chen, Jun ;
Wu, Shan ;
Ren, Jun .
NEURAL REGENERATION RESEARCH, 2011, 6 (24) :1883-1887
[7]   Sonography and electrodiagnosis in carpal tunnel syndrome diagnosis, an analysis of the literature [J].
Chloros, George D. ;
Cartwright, Michael S. ;
Walker, Francis O. ;
Wiesler, Ethan R. .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (01) :141-143
[8]   Usefulness of additional measurements of the median nerve with ultrasonography [J].
Claes, F. ;
Meulstee, J. ;
Luttikhuis, T. T. M. Claessen-Oude ;
Huygen, P. L. M. ;
Verhagen, W. I. M. .
NEUROLOGICAL SCIENCES, 2010, 31 (06) :721-725
[9]   Carpal Tunnel Syndrome Assessment with Ultrasonography: Value of Inlet-to-Outlet Median Nerve Area Ratio in Patients versus Healthy Volunteers [J].
Fu, Tengfei ;
Cao, Manlin ;
Liu, Fang ;
Zhu, Jiaan ;
Ye, Dongmei ;
Feng, Xianxuan ;
Xu, Yiming ;
Wang, Gang ;
Bai, Yuehong .
PLOS ONE, 2015, 10 (01)
[10]   Ultrasonography shows increased cross-sectional area of the median nerve in patients with arthritis and carpal tunnel syndrome [J].
Hammer, HB ;
Hovden, IAH ;
Haavardsholm, EA ;
Kvien, TK .
RHEUMATOLOGY, 2006, 45 (05) :584-588