Accuracy of 10 IOL power calculation formulas in 100 short eyes (≤ 22 mm)

被引:5
|
作者
Vilaltella, Magi [1 ,2 ]
Cid-Bertomeu, Pau [1 ]
Huerva, Valentin [1 ,2 ]
机构
[1] Univ Hosp Arnau Vilanova, Dept Ophthalmol, Lleida, Spain
[2] Univ Lleida, Fac Med, Dept Med & Surg, Lleida, Spain
关键词
Intraocular lens power calculation formulas; Short eyes; Cataract surgery; INTRAOCULAR-LENS POWER; PURSUING PERFECTION; HOFFER-Q; SRK/T;
D O I
10.1007/s10792-023-02660-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo assess and compare the accuracy of 10 intraocular lens (IOL) power calculation formulas after cataract surgery in eyes with an axial length (AL) shorter than or equal to 22.00 mm.MethodsA retrospective case series included 100 eyes with an AL <= 22.00 mm that underwent uneventful cataract surgery. The refractive prediction error (PE) was calculated using 10 different IOL power calculation formulas: Barrett Universal II, EVO 2.0, Haigis, Hill RBF 2.0, Hoffer Q, Holladay 1 and 2, Kane, SRK/T and SuperLadas. The median absolute prediction error (MedAE +/- SD) and mean absolute prediction error (MAE +/- SD) were calculated after adjusting the mean prediction error (ME) to 0.ResultsHoffer Q obtained the lowest MedAE (0.292 D) after adjusting the ME to 0, followed very closely by EVO 2.0 (0.298 D) and Kane (0.300 D). EVO 2.0 and Kane obtained both the lowest MAE after adjusting the ME to 0 (0.386). Differences in MAE among the different formulas were not statistically significant (p > 0.05).ConclusionsOur study reflects a tendency of the EVO 2.0 formula and the Kane formula along with the older Hoffer Q formula, to predict more accurately the refractive outcomes in short eyes that undergo cataract phacoemulsification surgery compared to the other formulas, despite this difference could not be statistically proved.
引用
收藏
页码:2613 / 2622
页数:10
相关论文
共 50 条
  • [41] A Comparative Study on the Accuracy of IOL Calculation Formulas in Nanophthalmos and Relative Anterior Microphthalmos
    Lin, Peimin
    Xu, Jie
    Miao, Ao
    Xu, Canqing
    Qian, Dongjin
    Lu, Yi
    Zheng, Tianyu
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 245 : 61 - 69
  • [42] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [43] The role of bilateral eyes and IOL prediction errors as bias in reliability of IOL power calculation studies
    Pellegrino, Isabella
    Capuano, Francesco M.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (09) : 1380 - 1381
  • [44] Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service
    Darcy, Kieren
    Gunn, David
    Tavassoli, Shokufeh
    Sparrow, John
    Kane, Jack X.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01): : 2 - 7
  • [45] The Effects of Ocular Biometric Parameters on the Accuracy of IOL Power Calculation
    Jiang, Cynthia Chelsea
    Hodson, Noah Michael
    Johnson, Daniel A.
    Kheirkhah, Ahmad
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [46] Comparison of Accuracy of IOL Power Calculation Formulas for SN60WF versus ZCB00 Lenses
    Hodson, Noah Michael
    Jiang, Cynthia Chelsea
    Johnson, Daniel A.
    Kheirkhah, Ahmad
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [47] Comment on: A Comparative Study on the Accuracy of IOL Calculation Formulas in Nanophthalmos and Relative Anterior Microphthalmos
    Ucar, Fikret
    Sagdic, Muhammed
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 251 : 197 - 197
  • [48] Effect of lens constants optimization on the accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Jia-Qing
    Zou, Xu-Yuan
    Zheng, Dan-Ying
    Chen, Wei-Rong
    Sun, Ao
    Luo, Li-Xia
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (06) : 943 - 948
  • [49] Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
    Liangpin Li
    Liyun Yuan
    Kun Yang
    Yanan Wu
    Simayilijiang Alafati
    Xia Hua
    Yan Wang
    Xiaoyong Yuan
    Scientific Reports, 13 (1)
  • [50] Precision of intraocular lens power Cheek for prediction in eyes shorter than 22 mm: An analysis of 6 formulas
    Shrivastava, Ankur K.
    Behera, Pranayee
    Kumar, Binod
    Nanda, Siddhartha
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (11): : 1317 - 1320