Accuracy of 10 IOL power calculation formulas in 100 short eyes (≤ 22 mm)

被引:5
|
作者
Vilaltella, Magi [1 ,2 ]
Cid-Bertomeu, Pau [1 ]
Huerva, Valentin [1 ,2 ]
机构
[1] Univ Hosp Arnau Vilanova, Dept Ophthalmol, Lleida, Spain
[2] Univ Lleida, Fac Med, Dept Med & Surg, Lleida, Spain
关键词
Intraocular lens power calculation formulas; Short eyes; Cataract surgery; INTRAOCULAR-LENS POWER; PURSUING PERFECTION; HOFFER-Q; SRK/T;
D O I
10.1007/s10792-023-02660-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo assess and compare the accuracy of 10 intraocular lens (IOL) power calculation formulas after cataract surgery in eyes with an axial length (AL) shorter than or equal to 22.00 mm.MethodsA retrospective case series included 100 eyes with an AL <= 22.00 mm that underwent uneventful cataract surgery. The refractive prediction error (PE) was calculated using 10 different IOL power calculation formulas: Barrett Universal II, EVO 2.0, Haigis, Hill RBF 2.0, Hoffer Q, Holladay 1 and 2, Kane, SRK/T and SuperLadas. The median absolute prediction error (MedAE +/- SD) and mean absolute prediction error (MAE +/- SD) were calculated after adjusting the mean prediction error (ME) to 0.ResultsHoffer Q obtained the lowest MedAE (0.292 D) after adjusting the ME to 0, followed very closely by EVO 2.0 (0.298 D) and Kane (0.300 D). EVO 2.0 and Kane obtained both the lowest MAE after adjusting the ME to 0 (0.386). Differences in MAE among the different formulas were not statistically significant (p > 0.05).ConclusionsOur study reflects a tendency of the EVO 2.0 formula and the Kane formula along with the older Hoffer Q formula, to predict more accurately the refractive outcomes in short eyes that undergo cataract phacoemulsification surgery compared to the other formulas, despite this difference could not be statistically proved.
引用
收藏
页码:2613 / 2622
页数:10
相关论文
共 50 条
  • [1] Accuracy of 10 IOL power calculation formulas in 100 short eyes (≤ 22 mm)
    Magí Vilaltella
    Pau Cid-Bertomeu
    Valentín Huerva
    International Ophthalmology, 2023, 43 : 2613 - 2622
  • [2] Comparison of six IOL power calculation formulas in eyes with axial length ≤22 mm
    Wang, Li
    Gokce, Sabite
    Zeiter, John
    Weikert, Mitchell P.
    Hill, Warren
    Koch, Douglas D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [3] Comparison of accuracy of recent IOL power formulas in short eyes
    Jun, Roo Min
    Gim, Yujin
    Han, Kyung Eun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [4] Clinical Accuracy of 18 IOL Power Formulas in 241 Short Eyes
    Voytsekhivskyy, Oleksiy V.
    Hoffer, Kenneth J.
    Savini, Giacomo
    Tutchenko, Larysa P.
    Hipolito-Fernandes, Diogo
    CURRENT EYE RESEARCH, 2021, 46 (12) : 1832 - 1843
  • [5] Comparison of the Accuracy of IOL Power Calculation Formulas for Pediatric Eyes in Children of Different Ages
    Kou, Jiaojiao
    Chang, Pingjun
    Lin, Lei
    Li, Zhangliang
    Fu, Yana
    Zhao, Yun-e
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [6] Accuracy of Newer Generation IOL Power Calculation Formulas in Eyes With High Axial Myopia
    Lin, Lei
    Xu, Mengxiang
    Mo, Er
    Huang, Shenghai
    Qi, Xiaoliang
    Gu, Siyi
    Sun, Weijie
    Su, Qiudong
    Li, Jin
    Zhao, Yun-e
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (11) : 754 - +
  • [7] Comparison of IOL Power Calculation Formulas for a Trifocal IOL in Eyes With High Myopia
    Tan, Qian
    Lin, Ding
    Wang, Li
    Chen, Bichao
    Tang, Qiongyan
    Chen, Xu
    Chen, Maosheng
    Tan, Jilin
    Zhang, Jingsong
    Wu, Lei
    Zhu, Xiaojun
    Wang, Yong
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (08) : 538 - +
  • [8] Comparison of IOL Calculation Formulas for Long and Short Axial Length Eyes
    Sandhu, Umar
    Hussain, Zain S.
    Griffin, David R.
    Cooke, David L.
    Riaz, Kamran M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [9] To compare the accuracy of intraocular lens calculation formulas in the prediction of postoperative refraction in eyes with short axial length (&lt;22mm)
    Shirke, Sheetal
    Gupta, Nishant
    Ahmed, Suheb
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [10] Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes
    Wang, Qiwei
    Jiang, Wu
    Lin, Tiao
    Wu, Xiaohang
    Lin, Haotian
    Chen, Weirong
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (04): : 356 - 363