The Minimum Effective Concentration (MEC95) of different volumes of ropivacaine for ultrasound-guided caudal epidural block: a dose-finding study

被引:2
|
作者
Ma, Dongmei [1 ]
Chen, Yan [2 ]
Chen, Ping [1 ]
Xu, Jianhong [1 ]
Guo, Jian [1 ]
Peng, Lijia [1 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 4, Sch Med, Dept Anesthesiol, Hangzhou, Zhejiang, Peoples R China
[2] Xinjiang Med Univ, Clin Med Coll 6, Dept Anesthesiol, Urumqi, Xinjiang, Peoples R China
关键词
Caudal epidural block; Ultrasound; Dixon up-and-down method; ANESTHESIA; BUPIVACAINE; GUIDANCE; SURGERY;
D O I
10.1186/s12871-023-02026-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BackgroundCaudal epidural block (CEB) may be beneficial in anorectal surgery because its use may extend postoperative analgesia. This dose-finding study aimed to estimate the minimum effective anesthetic concentrations for 95% patients(MEC95) of 20 ml or 25 ml of ropivacaine in with CEB.Patients and methodsIn this double-blind, prospective study, the concentration of ropivacaine administered in 20 ml and 25 ml for ultrasound-guided CEB were determined using the sample up-and-down sequential allocation study design of binary response variables. The first participant was given 0.5% ropivacaine. Depending on whether a block was successful or unsuccessful, the concentration of local anesthesia was decreased or increased by 0.025% in the next patient. Every five minutes for 30 min, the sensory blockade using a pin-prick sensation at S3 dermatome compared to at T6 dermatome were evaluated every 5 min within 30 min. An effective CEB was defined as a a reduction of sensation at S3 dermatome and the existence of flaccid anal sphincter. Anesthesia was considered successful if the surgeon could perform the surgery without additional anesthesia. We determined the MEC50 using the Dixon and Massey up-and-down method and estimated the MEC95 using probit regression.ResultsThe concentration of ropivacaine administered in 20 ml for CEB ranged from 0.2% to 0.5%. Probit regression with a bias-corrected Morris 95% CI derived by bootstrapping showed an MEC50 and MEC 50 of ropivacaine for anorectal surgical anesthesia were 0.27% (95% CI, 0.24 to 0.31) and 0.36%(95% CI, 0.32 to 0.61). The concentration of ropivacaine administered in 25 ml for CEB ranged from 0.175 to 0.5. Probit regression with a bias-corrected Morris 95% CI derived by bootstrapping showed an MEC50 and MEC95 for CEB were 0.24% (95% CI, 0.19 to 0.27) and 0.32% (95% CI, 0.28 to 0.54).ConclusionWith ultrasound-guided CEB, the MEC95 of 0.36% ropivacaine at 20 ml and 0.32% ropivacaine at 25 ml provide adequate surgical anesthesia/analgesia 95% of patients undergoing anorectoal surgery.
引用
收藏
页数:7
相关论文
共 43 条
  • [21] The median effective analgesic dose (ED50) of ropivacaine in ultrasound-guided transversus abdominis plane block for analgesia in reversal of ileostomy A double-blind up-down dose-finding study
    Lahlou-Casulli, Maria
    Chaize-Avril, Cecile
    Pouliquen, Emmanuel
    Desfourneaux, Veronique
    Mazoit, Jean-Xavier
    Malledant, Yannick
    Beloeil, Helene
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (09) : 640 - 644
  • [22] Effective volumes of 1.5% mepivacaine with different sodium concentration for ultrasound guided popliteal block
    Lopez, Mercedes
    Calvo, Miguel
    Sancho, Azahara
    Brogly, Nicolas
    Guasch, Emilia
    Gilsanz, Fernando
    JOURNAL OF CLINICAL ANESTHESIA, 2017, 37 : 139 - 144
  • [23] Distribution pattern of different volumes of ropivacaine in ultrasound-guided intertransverse process block: a randomized, blinded, computed tomography imaging study
    Wang, Chao-wei
    Zou, Ping
    Zhang, Zu-xiong
    Si, Mao-yan
    Yi, Qin-guo
    Zhan, Li-fang
    BMC ANESTHESIOLOGY, 2025, 25 (01):
  • [24] Minimum effective volume of ropivacaine 7.5mg/ml for an ultrasound-guided infraclavicular brachial plexus block
    Flohr-Madsen, S.
    Ytrebo, L. M.
    Kregnes, S.
    Wilsgaard, T.
    Klaastad, O.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2013, 57 (04) : 495 - 501
  • [25] Minimum effective volume of 0.2% ropivacaine for ultrasound-guided axillary brachial plexus block in preschool-age children
    Chen, Liang
    Shen, Yang
    Liu, Shuangmei
    Cao, Yanyan
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [26] The estimation of minimum effective volume of 0.5% ropivacaine in ultrasound-guided interscalene brachial plexus nerve block: A clinical trial
    Mittal, Kailash
    Janweja, Sarita
    Prateek
    Sangwan, Pushpender
    Agarwal, Deepa
    Tak, Himani
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2019, 35 (01) : 41 - 46
  • [27] Ropivacaine in ultrasound-guided femoral nerve block: what is the minimal effective anaesthetic concentration (EC90)?
    Taha, A. M.
    Abd-Elmaksoud, A. M.
    ANAESTHESIA, 2014, 69 (07) : 678 - 682
  • [28] Determination of ED50 and ED95 of 0.5% Ropivacaine in Adductor Canal Block to Produce Quadriceps Weakness A Dose-Finding Study
    Johnston, David F.
    Sondekoppam, Rakesh V.
    Giffin, Robert
    Litchfield, Robert
    Ganapathy, Sugantha
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2017, 42 (06) : 731 - 736
  • [29] Comparative study between ultrasound-guided pudendal nerve block and caudal epidural block anesthesia in children undergoing hypospadias surgery
    Waleed Abdalla Ibrahim Ahmed
    Mohamed Hossam Eldin Hamdy Abd El Wahab Shokier
    Amr Ahmed Ali Kasem
    Mohamed Hamed Abd El Aziz
    Sherif Gorge Anees Saed
    Ain-Shams Journal of Anesthesiology, 13
  • [30] Comparative study between ultrasound-guided pudendal nerve block and caudal epidural block anesthesia in children undergoing hypospadias surgery
    Ahmed, Waleed Abdalla Ibrahim
    Shokier, Mohamed Hossam Eldin Hamdy Abd El Wahab
    Kasem, Amr Ahmed Ali
    El Aziz, Mohamed Hamed Abd
    Saed, Sherif Gorge Anees
    AIN SHAMS JOURNAL OF ANESTHESIOLOGY, 2021, 13 (01)