Tertiary/quaternary treatment of urban wastewater by UV/H2O2 or ozonation: Microplastics may affect removal of E. coli and contaminants of emerging concern

被引:17
|
作者
Adeel, Mister [1 ]
Maniakova, Gulnara [1 ]
Rizzo, Luigi [1 ]
机构
[1] Univ Salerno, Dept Civil Engn, Water Sci & Technol Grp WaSTe, Via Giovanni Paolo 2 132, I-84084 Fisciano, SA, Italy
关键词
Advanced oxidation processes; Antibiotics; Contaminants of emerging concern; Microplastics; Wastewater disinfection; Wastewater reuse; ANTIBIOTIC-RESISTANT BACTERIA; TREATMENT PLANTS; ULTRAVIOLET-LIGHT; DISINFECTION; INACTIVATION; UV; OZONE; ENVIRONMENT; PHOTOLYSIS; DEPENDENCE;
D O I
10.1016/j.scitotenv.2023.167940
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to investigate the interference of polyethylene microplastics (MPs) on ultraviolet irradiation/hydrogen peroxide (UV/H2O2) and ozonation processes in the inactivation of E. coli bacteria (tertiary treatment) and removal of contaminants of emerging concern (CECs) (quaternary treatment) from simulated and real secondary treated urban wastewater. Three pharmaceuticals were investigated as model CECs, namely carbamazepine, sulfamethoxazole and trimethoprim. Experimental results showed that disinfection efficiency of UV/H2O2 treatment decreased (2.4, 1.8 and 1.3 log reductions of E. coli, initial H2O2 dose of 30 mg/L, 2.5 min treatment) as the initial concentration of MPs was increased (0.25, 0.5 and 1.0 g/L, respectively). Similarly, an increase in MPs concentration (0.25, 0.5 and 1.0 g/L) reduced the inactivation (4.7, 4.1 and 3.7 log reductions) of the target bacteria after 60 min of ozonation treatment. Although the disinfection efficiency of both treatment processes was negatively affected by the presence of MPs, UV/H2O2 was more effective than the ozonation, despite ozonation being investigated at high doses to better discriminate the effect of MPs. Noteworthy, CECs degradation by UV/H2O2 under realistic operating conditions was affected to some extent by MPs, while a lower effect was observed for ozonation, at not realistic ozone dose.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Removal of Organics and Degradation Products from Industrial Wastewater by a Membrane Bioreactor Integrated with Ozone or UV/H2O2 Treatment
    Laera, G.
    Cassano, D.
    Lopez, A.
    Pinto, A.
    Pollice, A.
    Ricco, G.
    Mascolo, G.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (02) : 1010 - 1018
  • [22] Assessment of phytotoxic potential and pathogenic bacteria removal from secondary effluents during ozonation and UV/H2O2
    Deroldo Sommaggio, Lais Roberta
    Oliveira, Flavio A.
    Malvestiti, Jacqueline Aparecida
    Christofoletti Mazzeo, Dania Elisa
    Levy, Carlos Emilio
    Dantas, Renato Falcao
    Marin-Morales, Maria Aparecida
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2022, 318
  • [23] Elimination efficiency of organic UV filters during ozonation and UV/H2O2 treatment of drinking water and wastewater effluent
    Seo, Changdong
    Shin, Jaedon
    Lee, Minju
    Lee, Woongbae
    Yoom, Hoonsik
    Son, Heejong
    Jang, Seongho
    Lee, Yunho
    CHEMOSPHERE, 2019, 230 : 248 - 257
  • [24] Ciprofloxacin ozonation in hospital wastewater treatment plant effluent: Effect of pH and H2O2
    De Witte, Bavo
    Van Langenhove, Herman
    Demeestere, Kristof
    Saerens, Karen
    De Wispelaere, Patrick
    Dewulf', Jo
    CHEMOSPHERE, 2010, 78 (09) : 1142 - 1147
  • [25] Comparative evaluation of ibuprofen removal by UV/H2O2 and UV/S2O82- processes for wastewater treatment
    Kwon, Minhwan
    Kim, Seonbaek
    Yoon, Yeojoon
    Jung, Youmi
    Hwang, Tae-Mun
    Lee, Junghyang
    Kang, Joon-Wun
    CHEMICAL ENGINEERING JOURNAL, 2015, 269 : 379 - 390
  • [26] Chelating agents supported solar photo-Fenton and sunlight/H2O2 processes for pharmaceuticals removal and resistant pathogens inactivation in quaternary treatment for urban wastewater reuse
    La Manna, Pellegrino
    De Carluccio, Marco
    Iannece, Patrizia
    Vigliotta, Giovanni
    Proto, Antonio
    Rizzo, Luigi
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 452
  • [27] Inactivation of Clostridium perfringens, Total Coliforms, and Escherichia coli by UV/H2O2 in Wastewater Treatment Plant Effluent
    Guimaraes, Jose Roberto
    Guadagnini, Regiane Aparecida
    Bueno Franco, Regina Maura
    dos Santos, Luciana Urbano
    JOURNAL OF ADVANCED OXIDATION TECHNOLOGIES, 2016, 19 (01) : 93 - 97
  • [28] Treatment of hospital laundry wastewater by UV/H2O2 process
    Jaqueline Pirão Zotesso
    Eneida Sala Cossich
    Vanderly Janeiro
    Célia Regina Granhen Tavares
    Environmental Science and Pollution Research, 2017, 24 : 6278 - 6287
  • [29] Transformation of persistent organic micropollutants by UV and UV/H2O2 in wastewater treatment plant effluent
    Thor, Jan
    Dittmann, Daniel
    Meyer, Andreas
    Zeeshan, Muhammad
    Johne, Steffen
    Reynaert, Eva
    Ruhl, Aki Sebastian
    Water Supply, 2025, 25 (01) : 65 - 82
  • [30] Treatment of hospital laundry wastewater by UV/H2O2 process
    Zotesso, Jaqueline Pirao
    Cossich, Eneida Sala
    Janeiro, Vanderly
    Granhen Tavares, Celia Regina
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (07) : 6278 - 6287