Analytical model for axially compressed circular concrete-filled double skin steel tubes (CFDSTs): Insights from concrete non-uniformly confined states

被引:6
作者
Cheng, Zhengqing [1 ]
Wang, Facheng [1 ]
Zhang, Deren [1 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
关键词
Concrete-filled double skin steel tube; Axial compression; Analytical model; Non-uniform confinement; Passive confinement; Steel tube-concrete interaction; STRESS-STRAIN CURVES; TUBULAR SHORT COLUMNS; PLASTIC-DAMAGE MODEL; HIGH-STRENGTH STEEL; STUB COLUMNS; ANALYTICAL BEHAVIOR; NONLINEAR-ANALYSIS; BUILDINGS ACI-318; THEORETICAL-MODEL; PLAIN CONCRETE;
D O I
10.1016/j.tws.2023.111106
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled double skin steel tube (CFDST) is becoming a competitive structural concept in deep-sea and deep-ground engineering structures. However, the passive non-uniform confinement of the sandwiched concrete needs to be further clarified and quantitatively described to achieve better design efficiency of CFDSTs in sophisticated application scenarios. This investigation suggests a development approach for the analytical model of the axially compressed circular CFDSTs considering the non-uniform confinement effect. The strength and deformation characteristics of the concrete subjected to constant lateral stresses have been first systematically analyzed through the extensively collected experimental database, and the corresponding constitutive models have been formulated accordingly. The stress distributions of the sandwiched concrete and the influence of the cross-sectional geometric properties have been discussed, and then the calculation method for the non-uniform confining factor has been developed. An efficient analytical model has been established on the basis of an incremental-iterative procedure, with the steel tube-concrete interaction and bonding behavior appropriately considered. The proposed analytical model has been verified through the widely collected experimental data of axially compressed CFDSTs, and the results show that it could effectively simulate the full-range axial load-strain curves and improve the prediction accuracy of ultimate loads by about 5% to 16% compared with the existing design formulas.
引用
收藏
页数:16
相关论文
共 108 条
  • [1] ACI committee 318, 2014, BUILDING CODE REQUIR
  • [2] Application of steel-concrete composite pile foundation system as energy storage medium
    Agibayeva, Aidana
    Lee, Deuckhang
    Ju, Hyunjin
    Zhang, Dichuan
    Kim, Jong R.
    [J]. STRUCTURAL ENGINEERING AND MECHANICS, 2021, 77 (06) : 753 - 763
  • [3] AHMAD SH, 1982, J AM CONCRETE I, V79, P484
  • [4] Fiber element modeling of circular double-skin concrete-filled stainless-carbon steel tubular columns under axial load and bending
    Ahmed, Mizan
    Liang, Qing Quan
    Hamoda, Ahmed
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (05) : 1114 - 1135
  • [5] Numerical modeling of axially loaded circular concrete-filled double-skin steel tubular short columns incorporating a new concrete confinement model
    Ahmed, Mizan
    Ci, Junchang
    Yan, Xi-Feng
    Lin, Siqi
    Chen, Shicai
    [J]. STRUCTURES, 2021, 30 : 611 - 627
  • [6] [Anonymous], 2004, Eurocode 2: Design of Concrete Structures-Part 1-1: General Rules and Rules for Buildings: BS EN 1992-1-1
  • [7] [Anonymous], 2011, Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary
  • [8] Analysis and review of concrete-filled double skin steel tubes under compression
    Ayough, Pouria
    Sulong, N. H. Ramli
    Ibrahim, Zainah
    [J]. THIN-WALLED STRUCTURES, 2020, 148
  • [9] Complete triaxial stress-strain curves of high-strength concrete
    Candappa, DC
    Sanjayan, JG
    Setunge, S
    [J]. JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2001, 13 (03) : 209 - 215
  • [10] [曹伟 Cao Wei], 2005, [土木工程学报, China Civil Engineering Journal], V38, P31