共 50 条
Validation of the Chinese drug hypersensitivity quality of life questionnaire: Role of delabeling
被引:0
|作者:
Mak, Hugo W. F.
[1
]
Chan, Elsie T. S.
[1
]
Yim, Jackie S. H.
[1
]
Lee, Elaine
[1
]
Lam, Dorothy L. Y.
[1
]
Chiang, Valerie
[2
]
Li, Philip H.
[1
,3
]
机构:
[1] Univ Hong Kong, Queen Mary Hosp, Dept Med, Div Rheumatol & Clin Immunol, Hong Kong, Peoples R China
[2] Queen Mary Hosp, Dept Pathol, Div Clin Immunol, Hong Kong, Peoples R China
[3] Univ Hong Kong, Queen Mary Hosp, Dept Med, Div Rheumatol & Clin Immunol,Pokfulam, 102 Pokfulam Rd, Hong Kong, Peoples R China
关键词:
Delabeling;
Drug allergy;
Penicillin;
Quality of life;
Questionnaire;
Validation;
PENICILLIN ALLERGY;
VERSION;
IMPACT;
RELIABILITY;
VALIDITY;
OUTCOMES;
COSTS;
D O I:
10.5415/apalergy.0000000000000020
中图分类号:
R392 [医学免疫学];
学科分类号:
100102 ;
摘要:
Background: The Drug Hypersensitivity Quality of Life Questionnaire (DrHy-Q) is not currently available in Chinese. Besides, penicillin allergy (PA) is a worldwide public health challenge, and delabeling inauthentic PA can improve clinical and economic outcomes. However, its effect on health-related quality of life (HRQoL) remains poorly known. Objective: The study objective is to translate and validate a Chinese version of DrHy-Q and investigate the effect of PA delabeling on HRQoL using DrHy-Q. Methods: A Chinese DrHy-Q was translated then completed by patients with drug allergy labels for psychometric validation. Afterwards, another cohort of patients finished the Chinese DrHy-Q before and after their PA workup for pre-post comparison. Results: A total of 130 patients were studied. Sixty-three patients (79.4% female; median age = 59 +/- 15 years) completed the Chinese DrHy-Q for validation (mean score = 38.9 +/- 23.5). It demonstrated excellent internal consistency (Cronbach a = 0.956; 95% confidence interval [CI], 0.939-0.971) and test-retest reliability (intraclass correlation coefficient = 0.993 [95% CI, 0.9690.998]). Construct validity was confirmed by its one-dimensional structure in factor analysis. Divergent validity was established because only 2 (out of 9) SF-36 scales showed weak negative correlations to DrHy-Q. Patients with multiple implicated drugs presented significantly higher DrHy-Q scores than those with only a single drug (42.0 +/- 22.5 vs 28.7 +/- 24.4; P = 0.038), showing discriminant validity. Subsequently, another 67 patients (73.1% female; median age = 56 +/- 15 years) underwent PA investigations and completed their pre-post DrHy-Q. A significant drop in DrHy-Q score was shown (40.8 +/- 21.7 vs 26.6 +/- 22.5; Cohen's d = 0.964; P < 0.001), reflecting improvement in HRQoL. Conclusion: The Chinese DrHy-Q is reliable and valid for HRQoL assessment. PA delabeling significantly benefits patients' HRQoL. Future larger-scale studies are warranted to corroborate our findings.
引用
收藏
页码:3 / 9
页数:7
相关论文