In vivo trueness of full-arch implant-supported CAD/CAM restorations and models based on conventional impressions

被引:5
|
作者
Nedelcu, Robert [1 ,6 ,7 ]
Olsson, Pontus [2 ,5 ]
Thulin, Mans [3 ,4 ]
Nystrom, Ingela [2 ]
Thor, Andreas [1 ]
机构
[1] Uppsala Univ, Dept Surg Sci Plast & Oral & Maxillofacial Surg, S-75185 Uppsala, Sweden
[2] Uppsala Univ, Ctr Image Anal, Dept Informat Technol, Box 337, S-75105 Uppsala, Sweden
[3] Univ Edinburgh, Sch Math, James Clerk Maxwell Bldg,Mayfield Rd, Edinburgh EH9 3FD, Scotland
[4] Univ Edinburgh, Maxwell Inst Math Sci, James Clerk Maxwell Bldg,Mayfield Rd, Edinburgh EH9 3FD, Scotland
[5] Savant AB, Rosenlundsgatan 52, S-11863 Stockholm, Sweden
[6] Univ Western Australia, UWA Dent Sch, Nedlands, WA 6009, Australia
[7] Uppsala Univ, Dept Surg Sci Plast & Oral & Maxillofacial Surg, Disciplinary Domain Med & Pharm, Kakkirurg Klin, Akadem Sjukhuset Ing 78-79 Sv, S-75185 Uppsala, Sweden
关键词
Trueness; Accuracy; Precision; in vivo; Implant impression; Framework misfit; INTRAORAL SCANNERS; PRECISION; FIT; ACCURACY; FRAMEWORKS; INSPECTION; PROSTHESES; MISFIT;
D O I
10.1016/j.jdent.2022.104381
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate a method for in situ reference acquisition of implant positions in complete edentulous maxillae using an industrial scanner. To assess in vivo trueness of full-arch implant-supported fixed dentures (IFD) and dental models based on conventional impressions.Methods: In five subjects, scan-bodies were mounted to six maxillary implants and scanned three times using an industrial scanner (REF). Original impression-based models used to manufacture existing IFDs, (MOD1), and models fabricated from new polyether impressions, (MOD2), were scanned three times with a laboratory scanner. Scan-bodies were aligned and exported with analogue positions corresponding to implant positions. Implant analogues were mounted onto existing IFDs and scanned three times (BRIDGE). CAD files of scan-bodies with inter-aligned CAD-analogues were geometry-aligned to REF. CAD-analogues were aligned to exported files of MOD1 and MOD2, and to BRIDGE. Resulting six CAD-analogues were Globally Aligned using a consistent geometry-based alignment. Deviations were computed after a Reference Point System Alignment at the implant/ prosthetic platform for Cartesian axes and a linear Resultant.Results: REF precision was 9.3 +/- 1 mu m. In vivo trueness for Resultant was MOD1: 36 +/- 16 mu m, MOD2: 28 +/- 7 mu m and BRIDGE: 70 +/- 23 mu m, where MOD1 and MOD2 were statistically significantly different from BRIDGE. In vitro manufacturing trueness of Resultant when MOD1 acted reference for BRIDGE was: 69 +/- 22.Conclusions: This method can be applied for assessing in vivo trueness. CAD/CAM processed IFD showed de-viations twice that of impression-based models, however, errors from impressions and subsequent model scans were not additive to the entire workflow.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses
    D'haese, Rani
    Vrombaut, Tom
    Roeykens, Herman
    Vandeweghe, Stefan
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [2] Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
    Drancourt, Noemie
    Auduc, Chantal
    Mouget, Aymeric
    Mouminoux, Jean
    Auroy, Pascal
    Veyrune, Jean-Luc
    El Osta, Nada
    Nicolas, Emmanuel
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [3] Rationale for a fixed implant-supported transitional prosthesis in full-arch implant restorations
    Leclercq, P.
    Dohan, D. M.
    REVUE DE STOMATOLOGIE DE CHIRURGIE MAXILLO-FACIALE ET DE CHIRURGIE ORALE, 2007, 108 (06) : 530 - 535
  • [4] The Precision of Fit of Cast and Milled Full-Arch Implant-Supported Restorations
    Paniz, Gianluca
    Stellini, Edoardo
    Meneghello, Roberto
    Cerardi, Andrea
    Gobbato, Edoardo Alvise
    Bressan, Eriberto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : 687 - 693
  • [5] Fixed Full-Arch Implant-Supported Restorations: Techniques Review and Proposal for Improvement
    Froimovici, Florin-Octavian
    Butnarasu, Cristian Corneliu
    Montanari, Marco
    Sandulescu, Mihai
    DENTISTRY JOURNAL, 2024, 12 (12)
  • [6] Do digital impressions have a greater accuracy for full-arch implant-supported reconstructions compared to conventional impressions? An in vitro study
    Shaikh, Mohsin
    Lakha, Tabrez
    Kheur, Supriya
    Qamri, Batul
    Kheur, Mohit
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 398 - 404
  • [7] Trueness of Extraoral Digital Impressions for Full-Arch Implant Impressions-In Vitro Study
    Sampaio-Fernandes, Manuel Antonio
    Pinto, Ricardo
    Almeida, Paulo Rocha
    Sampaio-Fernandes, Maria Margarida
    Marques, Duarte
    Figueiral, Maria Helena
    MATERIALS, 2024, 17 (12)
  • [8] Full-Arch Digital Implant Impression Trueness: An in Vivo Study
    Rutkunas, Vygandas
    Kules, Daniel
    Revilla-Leon, Marta
    Akulauskas, Mykolas
    Auskalnis, Liudas
    Gendviliene, Ieva
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [9] Trueness of IntraoralScanners in Different Scan Patterns for Full-Arch Digital Implant Impressions
    Sezer, Taygun
    Esim, Emir
    Yilmaz, Erkan
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (04) : 426 - 430
  • [10] Implant-supported full-arch restorations using an external spherical implant connection. A case series
    Vania, Stefano
    Paratelli, Andrea
    Bressan, Eriberto
    Pispero, Alberto
    DENTAL CADMOS, 2024, 92 (02)