Multiple Pulse Amperometry-An Antifouling Approach for Nitrite Determination Using Carbon Fiber Microelectrodes

被引:9
作者
Saraiva, Douglas P. M. [1 ]
Braga, Daniel V. [1 ]
Bossard, Bruna [1 ]
Bertotti, Mauro [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, Dept Fundamental Chem, Ave Prof Lineu Prestes 748, BR-05513970 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
nitrite; pulsed amperometry; electroanalysis; antifouling; FLOW-INJECTION ANALYSIS; ELECTROCHEMICAL DETERMINATION; ELECTROCATALYTIC OXIDATION; NITRATE; ELECTRODEPOSITION; PARACETAMOL; MECHANISM; SULFIDE; GOLD;
D O I
10.3390/molecules28010387
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Nitrite is a ubiquitous pollutant in modern society. Developing new strategies for its determination is very important, and electroanalytical methods present outstanding performance on this task. However, the use of bare electrodes is not recommended because of their predisposition to poisoning and passivation. We herein report a procedure to overcome these limitations on carbon fiber microelectrodes through pulsed amperometry. A three-pulse amperometry approach was used to reduce the current decay from 47% (after 20 min under constant potential) to virtually 0%. Repeatability and reproducibility were found to have an RSD lower than 0.5% and 7%, respectively. Tap water and synthetic inorganic saliva samples were fortified with nitrite, and the results obtained with the proposed sensor were in good agreement with the amount added.
引用
收藏
页数:11
相关论文
共 44 条
[1]   A chemiluminescence flow injection system for nitrite ion determination [J].
Amini, M. K. ;
Pourhossein, M. ;
Talebi, M. .
JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2005, 2 (04) :305-314
[2]  
[Anonymous], NITR OX MICR INSTR M
[3]  
[Anonymous], CODE FEDERAL REGULAT
[4]   Simultaneous Voltammetric/Amperometric Determination of Sulfide and Nitrite in Water at BDD Electrode [J].
Baciu, Anamaria ;
Ardelean, Magdalena ;
Pop, Aniela ;
Pode, Rodica ;
Manea, Florica .
SENSORS, 2015, 15 (06) :14526-14538
[5]   Antioxidant and antimicrobial preservatives: Properties, mechanism of action and applications in food - a review [J].
Bensid, Abdelkader ;
El Abed, Nariman ;
Houicher, Abderrahmane ;
Regenstein, Joe M. ;
Ozogul, Fatih .
CRITICAL REVIEWS IN FOOD SCIENCE AND NUTRITION, 2022, 62 (11) :2985-3001
[6]   A study of nitrite oxidation at platinum microelectrodes [J].
Bertotti, M ;
Pletcher, D .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 1997, 8 (04) :391-395
[7]   OXIDATIVE FLOW-INJECTION AMPEROMETRIC DETERMINATION OF NITRITE AT AN ELECTROCHEMICALLY PRE-TREATED GLASSY-CARBON ELECTRODE [J].
CHAMSI, AY ;
FOGG, AG .
ANALYST, 1988, 113 (11) :1723-1727
[8]   Simultaneous Determination of Caffeine, Ibuprofen, and Paracetamol by Flow-injection Analysis with Multiple-pulse Amperometric Detection on Boron-doped Diamond Electrode [J].
Chaves, Sandro C. ;
Aguiar, Priscila N. C. ;
Torres, Livia M. F. C. ;
Gil, Eric S. ;
Luz, Rita C. S. ;
Damos, Flavio S. ;
Munoz, Rodrigo A. A. ;
Richter, Eduardo M. ;
dos Santos, Wallans T. P. .
ELECTROANALYSIS, 2015, 27 (12) :2785-2791
[9]   Investigation of nitrite alternatives for the color stabilization of heme-iron hydrolysates [J].
Chhem-Kieth, Sorivan ;
Skou, Peter Baek ;
Lametsch, Rene ;
Hansen, Erik Torngaard ;
Ruiz-Carrascal, Jorge .
JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2018, 55 (10) :4287-4296
[10]   Liquid Chromatography Analysis of Common Nutritional Components, in Feed and Food [J].
Cortes-Herrera, Carolina ;
Artavia, Graciela ;
Leiva, Astrid ;
Granados-Chinchilla, Fabio .
FOODS, 2019, 8 (01)