Development of a QuEChERS combined with LC-MS/MS method for determining 24 sedatives and anesthetics in animal-derived foods

被引:4
作者
Wang, Menglin [1 ]
Qiao, Yan [1 ]
Luo, Zihan [1 ]
Guo, Erling [1 ]
Ma, Weihao [2 ]
Wang, Ke [2 ]
Guo, Aijing [2 ]
Lian, Kaoqi [1 ,3 ,4 ]
机构
[1] Hebei Med Univ, Sch Publ Hlth, Shijiazhuang 050017, Peoples R China
[2] Shijiazhuang Ctr Dis Control & Prevent, Shijiazhuang Technol Innovat Ctr Chem Poison Detec, Shijiazhuang 050011, Peoples R China
[3] Hebei Key Lab Environm & Human Hlth, Shijiazhuang 050017, Peoples R China
[4] Hebei Key Lab Forens Med, Shijiazhuang 050017, Hebei, Peoples R China
关键词
QuEChERS; LC-MS/MS; Anaesthetic; Sedatives; Food of animal origin; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; MULTIRESIDUE METHOD; PESTICIDE-RESIDUES; MASS-SPECTROMETRY; DRUG RESIDUES; WHOLE-BLOOD; BENZODIAZEPINES; METABOLITES;
D O I
10.1016/j.jfca.2024.106000
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
This study aims to establish a rapid, accurate, safe, inexpensive, and effective method that combines QuEChERS pre-treatment with liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 20 benzodiazepine sedatives (SDTs) and 4 eugenol anaesthetics (AETs) in chicken, canned fish, meat floss, and powdered milk such that technical support can be provided for monitoring residues of 24 SDTs and AETs in the food matrix and for protecting human life and health. Results demonstrated that all 24 SDTs and AETs exhibited good linearity in their corresponding concentration ranges with correlation coefficients (r) of > 0.999. The limit of detection (LOD) and limit of quantification (LOQ) were in the ranges of 0.01-0.22 and 0.03-0.67 mu g center dot kg(-1), respectively, and the recoveries were in the range of 70.04-110.26% (n = 7) with precision in the range of 0.75-9.99% (n = 7) for 24 SDTs and AETs at different concentrations (4, 20, and 100 mu g center dot kg(-1)). This method was successfully applied to real samples and provides a convenient tool for detecting residues of SDTs and AETs in animal-derived foods.
引用
收藏
页数:12
相关论文
共 59 条
[1]   High-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of diazepam, atropine and pralidoxime in human plasma [J].
Abbara, Chadi ;
Bardot, Isabelle ;
Cailleux, Annie ;
Lallement, Guy ;
Le Bouil, Anne ;
Turcant, Alain ;
Clair, Pascal ;
Diquet, Bertrand .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 874 (1-2) :42-50
[2]   Spectroscopic quantifiication of preservatives in different food matrices using QuEChERS extraction and multivariate calibration with comparison against liquid chromatography [J].
Abdelghani, Jafar, I ;
Al-Degs, Yahya S. .
ARABIAN JOURNAL OF CHEMISTRY, 2022, 15 (01)
[3]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[4]  
[Anonymous], 2023, FEMA Statement On Methyl Eugenol | FEMA [WWW Document]
[5]  
[Anonymous], 2002, Announcement No. 235 of the Ministry of Agriculture of the People's Republic of China
[6]  
[Anonymous], 2002, ANNOUNCEMENT NO 176
[7]   Quantitative determination of diazepam, nitrazepam and flunitrazepam in tablets using thin-layer chromatography-densitometry technique [J].
Bakavoli, M ;
Kaykhaii, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (06) :1185-1189
[8]   Screening of 23-lactams in foodstuffs by LC-MS/MS using an alkaline QuEChERS-like extraction [J].
Bessaire, Thomas ;
Mujahid, Claudia ;
Beck, Andrea ;
Tarres, Adrienne ;
Savoy, Marie-Claude ;
Woo, Pei-Mun ;
Mottier, Pascal ;
Desmarchelier, Aurelien .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2018, 35 (04) :661-673
[9]   Use of benzodiazepines among elderly patients [J].
Bogunovic, OJ ;
Greenfield, SF .
PSYCHIATRIC SERVICES, 2004, 55 (03) :233-235
[10]   Validation and uncertainties evaluation of an isotope dilution-SPE-LC-MS/MS for the quantification of drug residues in surface waters [J].
Brieudes, V. ;
Lardy-Fontan, S. ;
Lalere, B. ;
Vaslin-Reimann, S. ;
Budzinski, H. .
TALANTA, 2016, 146 :138-147