Investigation on the influence of geometric parameters on two-phase ejector performance with R290

被引:7
作者
Lu, Yu [1 ]
Bai, Tao [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Two-phase ejector; Geometry parameters; Component efficiencies; Experimental study; Empirical correlations; REFRIGERATION; OPTIMIZATION; SYSTEM; CYCLE;
D O I
10.1016/j.ijrefrig.2023.09.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, the effect of geometric parameters on a two-phase ejector performance was experimentally studied, and the R290 was used as the working fluid. The four geometric parameters of the ejector were discussed in detail, including the diameter of the nozzle throat (D-t), the nozzle exit position (NXP), the diameter of the mixing section (D-m) and the length of the mixing section (L-m). The experimental results indicated that the pressure lift ratio (r(p)) of the ejector was sensitive to D-t and NXP. Within the increase of D-t and NXP discussed in this paper, the r(p) of the ejector varied from 1.13 to 1.33 and 1.32 to 1.07, respectively. In addition, a maximum r(p) of the ejector could be obtained when D-m was 3 mm to 4 mm under different nozzle throat diameter. When the D-t was 0.7 mm, the entrainment ratio of the ejector varied from 0.402 to 1.406 as the D-m varied from 2 mm to 6 mm. The L-m of the ejector diffuser had little effect on the ejector performance. Moreover, the empirical correlations for the efficiencies of R290 two-phase ejector components were summarized based on the experimental result and ejector model.
引用
收藏
页码:102 / 112
页数:11
相关论文
共 50 条
[21]   Numerical investigation on performance optimization of steam ejector considering full geometric parameters and working conditions [J].
Guo, Dongjun ;
Wang, Jianbo ;
Zhu, Zhisong .
CASE STUDIES IN THERMAL ENGINEERING, 2024, 59
[22]   The experimental analysis of ejector-based R290 heat pump system for domestic applications [J].
Fingas, Rafal ;
Haida, Michal ;
Smolka, Jacek ;
Besagni, Giorgio ;
Palacz, Michal ;
Bodys, Jakub ;
Nowak, Andrzej J. .
15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, :340-347
[23]   Performance analysis of an ejector enhanced refrigeration cycle with R290/R600a for application in domestic refrigerator/freezers [J].
Chen, Qi ;
Yan, Gang ;
Yu, Jianlin .
APPLIED THERMAL ENGINEERING, 2017, 120 :581-592
[24]   Chiller Performance Study with Refrigerant R290 [J].
Fuadi, Zulfa ;
Yatim, Ardiyansyah ;
Rizky, Rachmah ;
Aisyah, Nyayu ;
Alhamid, Idrus ;
Budihardjo, Budihardjo ;
Putra, Nandy .
10TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2018): SMART CITY: ADVANCES IN THERMOFLUID TECHNOLOGY IN TROPICAL URBAN DEVELOPMENT, 2019, 2062
[25]   THE PERFORMANCE EVALUATION OF R744 TRANSCRITICAL EJECTOR AND R290/R744 CASCADE REFRIGERATION SYSTEMS FOR TURKEY [J].
Yilmaz, Deniz ;
Yilmaz, Baris ;
Mancuhan, Ebru .
THERMAL SCIENCE, 2019, 23 (06) :4031-4041
[26]   Analysis of two-phase ejector performance metrics and comparison of R134a and CO2 ejector performance [J].
Lawrence, Neal ;
Elbel, Stefan .
SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (05) :515-525
[27]   Influence of speed of sound in two-phase region on 1-D ejector performance modelling [J].
Kong, Ning ;
Qi, Zhaogang .
APPLIED THERMAL ENGINEERING, 2018, 139 :352-355
[28]   Numerical Modelling of Performance of R22 and R290 in Adiabatic Capillary Tubes Considering Metastable Two-Phase Region ——Theoretical Model Description and Validation [J].
周国兵 ;
张于峰 ;
郝红 .
Transactions of Tianjin University, 2005, (03) :209-215
[29]   Experimental analysis of the air-to-water ejector-based R290 heat pump system for domestic application [J].
Fingas, Rafal ;
Haida, Michal ;
Smolka, Jacek ;
Besagni, Giorgio ;
Bodys, Jakub ;
Palacz, Michal ;
Nowak, Andrzej J. .
APPLIED THERMAL ENGINEERING, 2024, 236
[30]   Numerical study of high-speed two-phase ejector performance with R134a refrigerant [J].
Baek, Sunghoon ;
Ko, Seungbin ;
Song, Simon ;
Ryu, Sungmin .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 126 :1071-1082