Optimization Strategies for Mass Spectrometry-Based Untargeted Metabolomics Analysis of Small Polar Molecules in Human Plasma

被引:3
作者
Kaczmarek, Michal [1 ]
Zhang, Nanyun [1 ]
Buzhansky, Ludmila [1 ]
Gilead, Sharon [1 ]
Gazit, Ehud [1 ,2 ]
机构
[1] Tel Aviv Univ, Blavatnik Ctr Drug Discovery, Div Metabolite Med, IL-69978 Tel Aviv, Israel
[2] Tel Aviv Univ, Shmunis Sch Biomed & Canc Res, IL-69978 Tel Aviv, Israel
关键词
untargeted metabolomics; method optimization; liquid chromatography; mass spectrometry; plasma; LC-MS; SAMPLE PREPARATION; HILIC-MS; PERFORMANCE; CHROMATOGRAPHY; COVERAGE; URINE;
D O I
10.3390/metabo13080923
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The untargeted approach to mass spectrometry-based metabolomics has a wide potential to investigate health and disease states, identify new biomarkers for diseases, and elucidate metabolic pathways. All this holds great promise for many applications in biological and chemical research. However, the complexity of instrumental parameters on advanced hybrid mass spectrometers can make the optimization of the analytical method immensely challenging. Here, we report a strategy to optimize the selected settings of a hydrophilic interaction liquid chromatography-tandem mass spectrometry method for untargeted metabolomics studies of human plasma, as a sample matrix. Specifically, we evaluated the effects of the reconstitution solvent in the sample preparation procedure, the injection volume employed, and different mass spectrometry-related operating parameters including mass range, the number of data-dependent fragmentation scans, collision energy mode, duration of dynamic exclusion time, and mass resolution settings on the metabolomics data quality and output. This study highlights key instrumental variables influencing the detection of metabolites along with suggested settings for the IQ-X tribrid system and proposes a new methodological framework to ensure increased metabolome coverage.
引用
收藏
页数:14
相关论文
共 29 条
  • [1] METABOLOMIC APPLICATIONS OF HILIC-LC-MS
    Cubbon, Simon
    Antonio, Carla
    Wilson, Julie
    Thomas-Oates, Jane
    [J]. MASS SPECTROMETRY REVIEWS, 2010, 29 (05) : 671 - 684
  • [2] A split-range acquisition method for the non-targeted metabolomic profiling of human plasma with hydrophilic interaction chromatography - high-resolution mass spectrometry
    Fall, Fanta
    Lenuzza, Natacha
    Lamy, Elodie
    Brollo, Marion
    Naline, Emmanuel
    Devillier, Philippe
    Thevenot, Etienne
    Grassin-Delyle, Stanislas
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1128
  • [3] Interfacing the orbitrap mass analyzer to an electrospray ion source
    Hardman, M
    Makarov, AA
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (07) : 1699 - 1705
  • [4] Cleaning up the masses: Exclusion lists to reduce contamination with HPLC-MS/MS
    Hodge, Kelly
    Ten Have, Sara
    Hutton, Luke
    Lamond, Angus I.
    [J]. JOURNAL OF PROTEOMICS, 2013, 88 : 92 - 103
  • [5] Toward 'Omic Scale Metabolite Profiling: A Dual Separation-Mass Spectrometry Approach for Coverage of Lipid and Central Carbon Metabolism
    Ivanisevic, Julijana
    Zhu, Zheng-Jiang
    Plate, Lars
    Tautenhahn, Ralf
    Chen, Stephen
    O'Brien, Peter J.
    Johnson, Caroline H.
    Marletta, Michael A.
    Patti, Gary J.
    Siuzdak, Gary
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (14) : 6876 - 6884
  • [6] An alternative sampling algorithm for use in liquid chromatography/tandem mass spectrometry experiments
    Kohli, BM
    Eng, JK
    Nitsch, RM
    Konietzko, U
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (05) : 589 - 596
  • [7] Lelli V., 2021, Metabolomics (p. Ch. 2). IntechOpen, DOI DOI 10.5772/INTECHOPEN.96852
  • [8] A systematic investigation of the effect of sample solvent on peak shape in nano- and microflow hydrophilic interaction liquid chromatography columns
    Li, Haibin
    Liu, Chusheng
    Zhao, Li
    Xu, Dongsheng
    Zhang, Tingting
    Wang, Qiqin
    Cabooter, Deirdre
    Jiang, Zhengjin
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2021, 1655
  • [9] Collision energy alteration during mass spectrometric acquisition is essential to ensure unbiased metabolomic analysis
    Madala, Ntakadzeni E.
    Steenkamp, Paul A.
    Piater, Lizelle A.
    Dubery, Ian A.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (02) : 367 - 372
  • [10] Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer
    Makarov, A
    Denisov, E
    Kholomeev, A
    Baischun, W
    Lange, O
    Strupat, K
    Horning, S
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (07) : 2113 - 2120