Enhanced Electrical Injury Using Triangular Interdigitated Electrodes for Catheter-Based Irreversible Electroporation

被引:1
|
作者
Lee, Dong-Jin [1 ,2 ]
Kim, Dae Yu [1 ,2 ,3 ]
机构
[1] Inha Univ, Inha Res Inst Aerosp Med, Incheon 22212, South Korea
[2] Inha Univ, Ctr Sensor Syst, Incheon 22212, South Korea
[3] Inha Univ, Coll Engn, Dept Elect & Comp Engn, Incheon 22212, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 14期
关键词
irreversible electroporation; triangular interdigitated electrodes; electrical injury; WALL THICKNESS; ABLATION;
D O I
10.3390/app13148455
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application The triangular interdigitated electrodes proposed in this paper could potentially provide an alternative strategy for designing interdigitated electrodes for catheter-based irreversible electroporation. Irreversible electroporation (IRE) is a promising nonthermal ablation technique that uses high-voltage electrical pulses to create permanent pores in the cell membrane of target tissue. Recently, endoscopic IRE with catheter-based electrodes has attracted significant attention as a potential alternative tool for gastrointestinal tumors, but it has been challenged owing to the limited electric field distribution in an in-plane electrode configuration, in which rectangular interdigitated electrodes (IDEs) are commonly used. Herein, we report an enhanced electrical injury in tissue using triangular IDEs that cause strong electric fields to be induced at the tip of the electrode fingers. A set of 10 pulses with a duration of 100 & mu;s and a frequency of 1 Hz were delivered to the tissue, and a finite element method was used to calculate the electrical injury in the gastrointestinal model. The probability of cell death by electrical injury at the triangular IDEs increases by approximately 10 times compared to that of conventional rectangular IDEs at the same electrode distance. These results could potentially pave the way toward designing electrodes in catheter-based IRE devices.
引用
收藏
页数:9
相关论文
共 23 条
  • [21] Catheter-Based Renal Denervation for the Treatment of Patients with Drug- Resistant Hypertension: EnligHTN I: Three-Month Data of a First in Man Study Using a Multi-Electrode Radiofrequency Ablation Catheter
    Papademetriou, Vasilios
    Worthley, Stephen G.
    Tsioufis, Costas
    Worthley, Matthew
    Chew, Derek
    Sinhal, Ajay
    Meredith, Ian
    Malaiapan, Yuvaraj
    CIRCULATION, 2012, 126 (21)
  • [22] Angle monitoring of directional energy deposition for catheter-based ultrasound thermal therapy using fitted changes in ultrasound backscatter energy imaging: ex vivo investigation
    Yang, Chengzhi
    Wang, Diya
    Jones, Peter D.
    Diederich, Chris J.
    Gupta, Pragya
    Zubair, Muhammad
    Burdette, Everette C.
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [23] Early Detection of Local Tumor Progression after Irreversible Electroporation (IRE) of Hepatocellular Carcinoma Using Gd-EOB-DTPA-Based MR Imaging at 3T
    Baeumler, Wolf
    Wiggermann, Philipp
    Luerken, Lukas
    Dollinger, Marco
    Stroszczynski, Christian
    Beyer, Lukas P.
    Schicho, Andreas
    CANCERS, 2021, 13 (07)