Research Progress on Audible Noise Emitted from HVDC Transmission Lines

被引:4
作者
Li, Li [1 ]
Meng, Wei [1 ]
Li, Qi [2 ,3 ]
Wang, Yifan [1 ]
Zheng, Xiaoguang [1 ]
Wang, Hongbin [4 ]
机构
[1] Elect Power Res Inst Guangdong Power Grid Co Ltd, Key Lab Environm Protect Guangdong Power Grid Co L, Guangzhou 510080, Peoples R China
[2] Xuefeng Mt Energy Equipment Safety Natl Observat &, Chongqing 400044, Peoples R China
[3] Univ Manchester, Dept Elect & Elect Engn, Manchester M13 9PL, England
[4] China Southern Power Grid, Guangzhou Power Supply Bur Guangdong Power Grid Co, Guangzhou 510620, Peoples R China
关键词
DC transmission line; audible noise; corona discharge; overview; CORONA CHARACTERISTICS; WAVE GENERATION; CAGE; BUNDLES; MODEL;
D O I
10.3390/en16124614
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The audible noise (AN) of DC transmission lines is a crucial factor affecting environmental assessment and electromagnetic design. In recent years, the public has paid increasing attention to the audible noise after the emergence of the HVDC technique. This paper emphatically reviewed the work investigating audible noise characteristics in both time and frequency domains, especially the correlation between sound and discharge. The proposed mechanisms of DC audible noise and the mitigating techniques are summarized, including the noise generation process, the physical models, the measurement method, and the mitigating technologies. It is found that the existing literature mainly focused on the prediction and characteristics of AN, the environmental factors which influence AN, and the methods to minimize AN emission. However, existing achievements still need to be improved to fully understand the mechanism of AN generation and solve the adaptability problem of AN prediction methods. The following aspects are valuable in future research: The correlation between audible noise and other corona effects will help solve the problem of difficulty in measuring audible noise in field condition; The corona discharge mechanism and weather resistance anti-corona coating when raindrops are attached to the surface of the transmission line, which will help guide the development and application of anti-corona coatings for the transmission line. Future research should also understand the mechanism of sound wave generation when considering the space charge effect.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Statistical Evaluation and Prediction of Audible Noise of HVDC Transmission Lines
    Yi, Yong
    Chen, Zhengying
    Wang, Liming
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 279 - 282
  • [2] The Altitude Effect and Correction of Audible Noise for HVdc Transmission Lines
    Zhao, Luxing
    Lu, Jiayu
    Cui, Xiang
    Xie, Li
    Ju, Yong
    He, Kun
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (04) : 1954 - 1963
  • [3] Space Propagation Characteristics of Audible Noise Due to HVDC Transmission Lines
    Shao Hua
    Hou Shanshan
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2017), 2017, 143 : 536 - 540
  • [4] Corona current and audible noise characteristics of HVDC transmission lines and their relationship at high-altitude
    Zhao, Luxing
    Xie, Li
    Liu, Chao
    Gao, Lei
    Qu, Jia
    Zhang, Hengzhi
    Liu, Yingyi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (15) : 3399 - 3409
  • [5] Audible Noise Calculation for Different Overhead Transmission Lines
    Kurniawan, Indra
    Suwarno
    Pischler, Oliver
    Schichler, Uwe
    2018 53RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2018,
  • [6] Influence of Humidity on Spectrum Characteristics of Audible Noise of DC Transmission Lines
    Yi, Yong
    Chen, Zhengying
    Wang, Liming
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 275 - 278
  • [7] Calculation and Research of Audible Noise of AC Transmission Lines (Ⅱ) - Distribution Under Crossing Erection
    Fu W.
    He W.
    Xie G.
    Liang Q.
    Lan L.
    Chen Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (12): : 4070 - 4078
  • [8] Calculation and Research of Audible Noise of AC Transmission Lines (Ⅰ) - Three-dimensional Distribution
    Xie G.
    Fu W.
    He W.
    Lan L.
    Wan B.
    Zhang Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (09): : 2990 - 2998
  • [9] Calculation model for the propagation of audible noise from high voltage transmission lines
    Li, Xuebao
    Cui, Xiang
    Lu, Tiebing
    He, Jiamei
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (08): : 2045 - 2052
  • [10] A Method for the Indirect Detection of Audible Noise From High-Voltage Direct Current Transmission Lines
    Liu, Yingyi
    Xv, Jiahuan
    Liu, Yuanqing
    Yuan, Haiwen
    Cui, Yong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (07) : 4358 - 4369