An integrated microfluidic chip-mass spectrometry system for rapid antimicrobial resistance analysis of bacteria producing ?-lactamases

被引:14
作者
Su, Zhaochen [1 ]
Hu, Wanting [1 ]
Ye, Lizhen [1 ]
Gao, Dan [1 ]
Lin, Jin-Ming [2 ]
机构
[1] Tsinghua Univ, Tsinghua Shenzhen Int Grad Sch, State Key Lab Chem Oncogen, Key Lab Chem Biol, Shenzhen 518055, Peoples R China
[2] Tsinghua Univ, Dept Chem, Beijing Key Lab Microanalyt Methods & Instrumentat, Key Lab Bioorgan Phosphorus Chem & Chem Biol, Beijing 100084, Peoples R China
关键词
Microfluidics; Mass spectrometry; -lactamases; Antimicrobial resistance; Inhibitor; DESORPTION IONIZATION-TIME; BETA-LACTAMASE; EXTRACTION;
D O I
10.1016/j.cclet.2022.107790
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Bacteria producing fi-lactamases have become a major issue in the global public health field. To restrain the development of drug resistance and reduce the abuse of antibiotics, it is very important to rapidly identify bacteria producing fi-lactamases and put forward a reasonable treatment plan. Here, an inte-grated microfluidic chip-mass spectrometry system was proposed for rapid screening of fi-lactamase-producing bacteria and optimization of fi-lactamase inhibitor dosing concentration. The concentration gradient generator followed by an array of bacterial culture chambers, as well as micro-solid-phase ex-traction columns was designed for sample pretreatment before mass analysis. By using the combina-tion system, the process of the hydrolysis of antibiotics by fi-lactamase-producing bacteria could be an-alyzed. To validate the feasibility, four antibiotics and two antibiotic inhibitors were investigated using three strains including negative control, SHV-1 and TEM-1 strains. SHV-1 and TEM-1 strains were suc-cessfully distinguished as the fi-lactamase producing strains. And the acquired optimal concentrations of fi-lactamase inhibitors were in accordance with the results by that obtained from the traditional microdi-lution broth method. The total analysis time only needed around 2 h, which was faster than conventional methods that require a few days. The technique presented herein provides an easy and rapid protocol for fi-lactamase resistance related studies, which is important for the inhibition of antimicrobial resistance development and the reduction of antibiotics abuse.(c) 2023 Published by Elsevier B.V. on behalf of Chinese Chemical Society and Institute of Materia Medica, Chinese Academy of Medical Sciences.
引用
收藏
页数:4
相关论文
共 40 条
  • [1] Cell analysis on chip-mass spectrometry
    Mao, Sifeng
    Li, Weiwei
    Zhang, Qiang
    Zhang, Wanling
    Huang, Qiushi
    Lin, Jin-Ming
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 107 : 43 - 59
  • [2] Online Monitoring of Lactate Efflux by Multi-Channel Microfluidic Chip-Mass Spectrometry for Rapid Drug Evaluation
    Liu, Wu
    Lin, Jin-Ming
    ACS SENSORS, 2016, 1 (04): : 344 - 347
  • [3] An integrated microfluidic chip for the analysis of biochemical reactions by MALDI mass spectrometry
    Sang-Ho Lee
    Chang-Soo Lee
    Byung-Gee Kim
    Yong-Kweon Kim
    Biomedical Microdevices, 2008, 10 : 1 - 9
  • [4] An integrated microfluidic chip for the analysis of biochemical reactions by MALDI mass spectrometry
    Lee, Sang-Ho
    Lee, Chang-Soo
    Kim, Byung-Gee
    Kim, Yong-Kweon
    BIOMEDICAL MICRODEVICES, 2008, 10 (01) : 1 - 9
  • [5] Microfluidic filter device coupled mass spectrometry for rapid bacterial antimicrobial resistance analysis
    Zhang, Dongxue
    Zhang, Yijie
    Yin, Fan
    Qin, Qin
    Bi, Hongyan
    Liu, Baohong
    Qiao, Liang
    ANALYST, 2021, 146 (02) : 515 - 520
  • [6] Occurrence of antimicrobial resistance bacteria in the Yodo River basin, Japan and determination of beta-lactamases producing bacteria
    Yamashita, Naoyuki
    Katakawa, Yohei
    Tanaka, Hiroaki
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2017, 143 : 38 - 45
  • [7] Integrated microfluidic chip coupled to mass spectrometry: A minireview of chip pretreatment methods and applications
    Chen, Jing
    Tang, Minmin
    Xu, Danke
    JOURNAL OF CHROMATOGRAPHY OPEN, 2021, 1
  • [8] MALDI-TOF Mass Spectrometry Technology as a Tool for the Rapid Diagnosis of Antimicrobial Resistance in Bacteria
    Yoon, Eun-Jeong
    Jeong, Seok Hoon
    ANTIBIOTICS-BASEL, 2021, 10 (08):
  • [9] Rapid detection of antimicrobial resistance by MALDI-TOF mass spectrometry
    Oviano, Marina
    Dolores Rojo, Maria
    Navarro Mari, Jose Maria
    Bou, German
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2016, 34 : 36 - 41
  • [10] Towards a modular microfluidic system for proteome analysis by mass spectrometry
    Figeys, D
    MICRO TOTAL ANALYSIS SYSTEMS '98, 2000, : 457 - 462