共 36 条
A mathematical model for investigation of dry band location on 22 kV bushing with and without RTV coating: Experimental study
被引:0
作者:
Kalaivani, L.
[1
]
Maheswari, R. V.
[1
]
Makki, Emad
[2
]
Singh, Bharat
[3
]
Warkad, Sanjay B.
[4
]
Girie, Jayant
[5
]
Vigneshwarana, B.
Karthick, Alagar
[6
]
Zahra, Musaddak Maher Abdul
[7
]
Kumarh, Abhinav
[8
]
Panchali, Hitesh
[9
]
机构:
[1] Natl Engn Coll, Dept Elect & Elect Engn, Kovilpatti 628503, India
[2] Umm Al Qura Univ, Coll Engn & Architecture, Dept Mech Engn, Mecca 24382, Saudi Arabia
[3] GLA Univ, Dept Mech Engn, Mathura, India
[4] P R Pote Patil Coll Engn & Management, Dept Elect Engn, Amravati 444603, India
[5] Yeshwantrao Chavan Coll Engn, Dept Mech Engn, Nagpur, India
[6] KPR Inst Engn & Technol, Dept Elect & Elect Engn, Renewable Energy Lab, Coimbatore 641407, Tamilnadu, India
[7] Al Mustaqbal Univ, Coll Engn & Technol, Comp Tech Engn Dept, Babil, Iraq
[8] Ural Fed Univ, Dept Nucl & Renewable Energy, 19 Mira St, Ekaterinburg 620002, Russia
[9] Gujarat Technol Univ, Nr Vishwakarma Govt Engn Coll, Nr Visat Three Rd, Ahmadabad 382424, Gujarat, India
来源:
关键词:
Mathematical model;
Numerical approach;
ESDD;
RTV coating;
Solid layer method;
Dry band;
POLLUTION FLASHOVER;
CERAMIC INSULATORS;
VOLTAGE;
AC;
SURFACE;
ARC;
D O I:
10.1016/j.mex.2024.102579
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
As different pollutants are deposited on the high voltage bushings, a dry band forms, which causes a flashover. The bushing's contaminated layer will weaken its insulation and have an impact on its electrical characteristics. The performance of bushings in dry band conditions of various lengths was investigated in this proposed piece of work, and a dynamic arc model is presented for the arc process in polluted bushings. It shows satisfactory performance in modelling the arc variables for various dry band positions. The developed dynamic open model for contaminated bushings with and without RTV coating predicted the flashover voltage and dry band positions. Any type of contamination, such as sea salt, road salt, and industrial pollutants prevalent in several sites, can be studied using the established model. Ultimately, it was discovered that there was good agreement between the model's results and the outcomes of the experiments. center dot Mathematical modeling of 22 kV bushing is conceded out for diverse polluted dry band location at lead-in, lead-out and middle region of bushing surface. center dot Dynamic arc modeling involved in bushing flashover process for different dry band location is done and flashover voltage is predicted center dot Experimental work is carried out to find FOV for the bushing with different dry location and compared with predicted FOV.
引用
收藏
页数:13
相关论文