Clinical Implications of Peak Inspiratory Flow in COPD: Post Hoc Analyses of the TRONARTO Study

被引:3
作者
Mahler, Donald A. [1 ,2 ]
Watz, Henrik [3 ]
Emerson-Stadler, Rachel [4 ]
Ritz, John [5 ]
Gardev, Asparuh [4 ]
Shaikh, Asif [6 ]
Drummond, M. Bradley [7 ]
机构
[1] Geisel Sch Med Dartmouth, Hanover, NH 03755 USA
[2] Valley Reg Hosp, Claremont, NH 03743 USA
[3] Pulm Res Inst LungenClin Grosshansdorf, Grosshansdorf, Germany
[4] Boehringer Ingelheim Int GmbH, Ingelheim, Germany
[5] Syneos Hlth, Somerset, NJ USA
[6] Boehringer Ingelheim Pharmaceut Inc, Ridgefield, CT USA
[7] Univ N Carolina, Pulm Dis & Crit Care Med, Chapel Hill, NC USA
来源
INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE | 2023年 / 18卷
关键词
COPD; dry powder inhaler; DPI; PIF; suboptimal; congress; variability; characteristics; OBSTRUCTIVE PULMONARY-DISEASE; SOFT MIST; INHALER; RATES;
D O I
10.2147/COPD.S404243
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: In patients with COPD, inhalation ability should be assessed when considering inhaler choice. To evaluate whether the soft mist inhaler (SMI) is suitable for COPD patients irrespective of inhalation ability, the TRONARTO study investigated the efficacy of dual long-acting bronchodilator therapy delivered via the Respimat & REG; SMI on lung function in patients with COPD stratified by inhalation ability. Tiotropium/olodaterol delivered via the SMI was effective both in patients with peak inspiratory flow (PIF) <60 L/min and PIF & GE;60 L/min, measured against medium-low resistance.Methods: This congress compilation summarizes post hoc analyses from the TRONARTO study presented at the annual American Thoracic Society 2022 and European Respiratory Society 2022 meetings. These analyses evaluated PIF in over 200 patients, with PIF measurements taken daily at home for 4 weeks, and in the clinic at baseline, Weeks 2 and 4.Results: Overall, 57.9% of patients had a PIF range (difference between lowest and highest PIF measurements) <20 L/min (12.4% of patients had PIF range <10 L/min). At-home PIF range decreased over the study period, suggesting that inhaler training/repeated PIF measurements may help to make patients' inspiratory effort more consistent. Some patient characteristics correlated with lower PIF (female gender, shorter stature, more severe disease, worse airflow obstruction) and lower PIF range (more severe disease). PIF measurements differed between medium-low and high-resistance settings, highlighting the importance of measuring PIF at the resistance of a patient's inhaler. PIF correlated poorly with spirometry measurements.Conclusion: As indicated in COPD management guidelines, choice of inhaler is essential to optimize pharmacologic therapies for COPD. Poor inspiratory ability should be viewed as a treatable trait that can help to inform inhaler choice. Inhaler training and consideration of PIF (if patients use a dry powder inhaler) can reduce patient-to-inhaler mismatch, with potential consequences for health status and exacerbation risk.
引用
收藏
页码:1729 / 1740
页数:12
相关论文
共 50 条
[21]   Clinical Burden of Chronic Obstructive Pulmonary Disease in Patients with Suboptimal Peak Inspiratory Flow [J].
Ohar, Jill A. ;
Mahler, Donald A. ;
Davis, Gabrielle N. ;
Lombardi, David A. ;
Moran, Edmund J. ;
Crater, Glenn D. .
CANADIAN RESPIRATORY JOURNAL, 2024, 2024
[22]   Successful Use of Easyhaler® Dry Powder Inhaler in Patients with Chronic Obstructive Pulmonary Disease; Analysis of Peak Inspiratory Flow from Three Clinical Trials [J].
Annette Kainu ;
Ville A. Vartiainen ;
Witold Mazur ;
Hanna Hisinger-Mölkänen ;
Federico Lavorini ;
Christer Janson ;
Martin Andersson .
Pulmonary Therapy, 2024, 10 :133-142
[23]   Successful Use of Easyhaler® Dry Powder Inhaler in Patients with Chronic Obstructive Pulmonary Disease; Analysis of Peak Inspiratory Flow from Three Clinical Trials [J].
Kainu, Annette ;
Vartiainen, Ville A. ;
Mazur, Witold ;
Hisinger-Molkanen, Hanna ;
Lavorini, Federico ;
Janson, Christer ;
Andersson, Martin .
PULMONARY THERAPY, 2024, 10 (01) :133-142
[24]   Prevalence of Critical Errors and Insufficient Peak Inspiratory Flow in Patients Hospitalized With COPD in a Department of General Internal Medicine: A Cross-Sectional Study [J].
Grandmaison, Gael ;
Grobety, Thomas ;
Vaucher, Julien ;
Hayoz, Daniel ;
Suter, Philipp .
CHRONIC OBSTRUCTIVE PULMONARY DISEASES-JOURNAL OF THE COPD FOUNDATION, 2024, 11 (04) :406-415
[25]   Clinical characteristics of chronic obstructive pulmonary disease patients with superoptimal peak inspiratory flow rate [J].
Kim, Taeyun ;
Moon, Ji-Yong ;
Park, Hye Yun ;
Kim, Youlim ;
Rhee, Chin Kook ;
Lee, Chang Youl ;
Park, Joo Hun ;
Park, Yong Bum ;
Russell, Richard ;
Yoo, Kwang Ha ;
Ra, Seung Won .
SCIENTIFIC REPORTS, 2024, 14 (01)
[26]   Peak-Inspiratory-Flow-Rate Guided Inhalation Therapy Reduce Severe Exacerbation of COPD [J].
Chen, Shih-Yu ;
Huang, Chun-Kai ;
Peng, Hui-Chuan ;
Tsai, Hsing-Chen ;
Huang, Szu-Ying ;
Yu, Chong-Jen ;
Chien, Jung-Yien .
FRONTIERS IN PHARMACOLOGY, 2021, 12
[27]   Prevalence and COPD Phenotype for a Suboptimal Peak Inspiratory Flow Rate against the Simulated Resistance of the Diskus® Dry Powder Inhaler [J].
Mahler, Donald A. ;
Waterman, Laurie A. ;
Gifford, Alex H. .
JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (03) :174-179
[28]   Changes in Peak Inspiratory Flow After Acute Bronchodilation: An Observational Study of Patients with Stable Chronic Obstructive Pulmonary Disease [J].
Pleasants, Roy A. ;
Shaikh, Asif ;
Henderson, Ashley G. ;
Bayer, Valentina ;
Drummond, M. Bradley .
JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2024, 37 (04) :171-179
[29]   Clinical evaluation of the peak inspiratory flow generated by asthmatic children through the Novolizer® [J].
Vogelberg, C ;
Kremer, HJ ;
Ellers-Lenz, B ;
Engel, M ;
Maus, J ;
Conrad, F ;
Hermann, R .
RESPIRATORY MEDICINE, 2004, 98 (10) :924-931
[30]   Peak inspiratory flow rates through placebo dry powder inhaler device in various asthma and COPD patients [J].
Jogi, Rain ;
Julge, Kaja ;
Samaruutel, Priit ;
Raatikainen, Liisa ;
Vanto, Timo .
EUROPEAN RESPIRATORY JOURNAL, 2012, 40