Field-portable detection of fentanyl and its analogs: A review

被引:14
作者
Crocombe, Richard A. [1 ,8 ]
Giuntini, Greg [2 ]
Schiering, David W. [3 ,4 ]
Profeta, Luisa T. M. [5 ]
Hargreaves, Michael D. [5 ]
Leary, Pauline E. [6 ]
Brown, Christopher D. [7 ]
Chmura, Jessamyn Ward [7 ]
机构
[1] Crocombe Spectroscop Consulting, Winchester, MA USA
[2] DetectaChem Inc, Sugar Land, TX USA
[3] RedWave Technol, Danbury, CT USA
[4] Miami Univ, Dept Chem & Biochem, Oxford, OH USA
[5] Rigaku Corp, Wilmington, MA USA
[6] Noble Inc, Lexington, KY USA
[7] 908 Devices, Boston, MA USA
[8] Crocombe Spectroscop Consulting, 30 Thornberry Rd, Winchester, MA 01890 USA
关键词
fentanyl; fentanyl analogs; FT-IR spectroscopy; gas chromatography; mass spectrometry; handheld spectroscopy; high-pressure mass spectrometry; ion mobility spectrometry; Raman spectroscopy; ON-SITE; RAMAN; DRUGS; SPECTROSCOPY; SPECTRA; DEATHS; SENSOR; STATES;
D O I
10.1111/1556-4029.15355
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The need to detect fentanyl and its analogs in the field is an important capability to help prevent unintentional exposure or overdose on these substances, which may result in death. Many portable methods historically used in the field by first responders and other field users to detect and identify other chemical substances, such as hazardous materials, have been applied to the detection and identification of these synthetic opioids. This paper describes field portable spectroscopic methods used for the detection and identification of fentanyl and its analogs. The methods described are automated colorimetric tests including lateral flow assays; vibrational spectroscopy (mid-infrared and Raman); gas chromatography-mass spectrometry; ion mobility spectrometry, and high-pressure mass spectrometry. In each case the background and key details of these technologies are outlined, followed by a discussion of the application of the technology in the field. Attention is paid to the analysis of complex mixtures and limits of detection, including the required spectral databases and algorithms used to interrogate these types of samples. There is also an emphasis on providing actionable information to the (likely) non-scientist operators of these instruments in the field.
引用
收藏
页码:1570 / 1600
页数:31
相关论文
共 153 条
[1]  
Agilent Technologies Inc, VAYA HANDH RAM SPECT
[2]   Portable testing techniques for the analysis of drug materials [J].
Alonzo, Morgan ;
Alder, Rhiannon ;
Clancy, Laura ;
Fu, Shanlin .
WILEY INTERDISCIPLINARY REVIEWS: FORENSIC SCIENCE, 2022, 4 (06)
[3]   Evaluation of a lateral flow immunoassay for the detection of the synthetic opioid fentanyl [J].
Angelini, Daniel J. ;
Biggs, Tracey D. ;
Maughan, Michele N. ;
Feasel, Michael G. ;
Sisco, Edward ;
Sekowski, Jennifer W. .
FORENSIC SCIENCE INTERNATIONAL, 2019, 300 :75-81
[4]  
[Anonymous], FORENSICS SOURCE
[5]  
[Anonymous], 2013, World Drug Report 2013
[6]  
[Anonymous], 2020, DRUG ENF ADM COMM OU
[7]  
[Anonymous], DETECTACHEM MOBILEDE
[8]  
[Anonymous], Harm Reduction
[9]  
[Anonymous], 2018, NIST Chemistry WebBook, SRD 69, DOI [DOI 10.18434/T4D303, 10.18434/T4D303]
[10]   Advanced Algorithms for the Identification of Mixtures Using Condensed-Phase FT-IR Spectroscopy [J].
Arno, Josep ;
Andersson, Greger ;
Levy, Dustin ;
Tomczyk, Carol ;
Zou, Peng ;
Zuidema, Eric .
NEXT-GENERATION SPECTROSCOPIC TECHNOLOGIES IV, 2011, 8032