Comparison of electrical impedance tomography and spirometry-based measures of airflow in healthy adult horses

被引:1
|
作者
Byrne, David P. [1 ]
Keeshan, Ben [2 ]
Hosgood, Giselle [1 ]
Adler, Andy [2 ]
Mosing, Martina [3 ]
机构
[1] Murdoch Univ, Sch Vet Med, Perth, WA, Australia
[2] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON, Canada
[3] Univ Vet Med, Dept Compan Anim & Horses, Anaesthesiol & Perioperat Intens Care, Vienna, Austria
关键词
asthma; equine; expiratory; inspiratory; peak flow; plethysmography; REGIONAL LUNG-FUNCTION; RESPIRATORY-FUNCTION; ANESTHETIZED HORSES; VENTILATION; OBSTRUCTION; ANESTHESIA; FREQUENCY; PRESSURE; HEAVES; MASK;
D O I
10.3389/fphys.2023.1164646
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Electrical impedance tomography (EIT) is a non-invasive diagnostic tool for evaluating lung function. The objective of this study was to compare respiratory flow variables calculated from thoracic EIT measurements with corresponding spirometry variables. Ten healthy research horses were sedated and instrumented with spirometry via facemask and a single-plane EIT electrode belt around the thorax. Horses were exposed to sequentially increasing volumes of apparatus dead space between 1,000 and 8,500 mL, in 5-7 steps, to induce carbon dioxide rebreathing, until clinical hyperpnea or a tidal volume of 150% baseline was reached. A 2-min stabilization period followed by 2 minutes of data collection occurred at each timepoint. Peak inspiratory and expiratory flow, inspiratory and expiratory time, and expiratory nadir flow, defined as the lowest expiratory flow between the deceleration of flow of the first passive phase of expiration and the acceleration of flow of the second active phase of expiration were evaluated with EIT and spirometry. Breathing pattern was assessed based on the total impedance curve. Bland-Altman analysis was used to evaluate the agreement where perfect agreement was indicated by a ratio of EIT:spirometry of 1.0. The mean ratio (bias; expressed as a percentage difference from perfect agreement) and the 95% confidence interval of the bias are reported. There was good agreement between EIT-derived and spirometry-derived peak inspiratory [-15% (-46-32)] and expiratory [10% (-32-20)] flows and inspiratory [-6% (-25-18)] and expiratory [5% (-9-20)] times. Agreement for nadir flows was poor [-22% (-87-369)]. Sedated horses intermittently exhibited Cheyne-Stokes variant respiration, and a breath pattern with incomplete expiration in between breaths (crown-like breaths). Electrical impedance tomography can quantify airflow changes over increasing tidal volumes and changing breathing pattern when compared with spirometry in standing sedated horses.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A Virtual Electrode-Based Enhanced GREIT Method for Electrical Impedance Tomography
    Liu, Zhenyou
    Zhang, Zhanlong
    He, Wei
    Song, Yang
    IEEE SENSORS JOURNAL, 2024, 24 (08) : 12957 - 12970
  • [22] Qualitative and quantitative assessment of pendelluft: a simple method based on electrical impedance tomography
    Sang, Ling
    Zhao, Zhanqi
    Yun, Po-Jen
    Frerichs, Inez
    Moeller, Knut
    Fu, Feng
    Liu, Xiaoqing
    Zhong, Nanshan
    Li, Yimin
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (19)
  • [23] A shape-based quality evaluation and reconstruction method for electrical impedance tomography
    Antink, Christoph Hoog
    Pikkemaat, Robert
    Malmivuo, Jaakko
    Leonhardt, Steffen
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (06) : 1161 - 1177
  • [24] A pressure mapping imaging device based on electrical impedance tomography of conductive fabrics
    Yao, A.
    Soleimani, M.
    SENSOR REVIEW, 2012, 32 (04) : 310 - 317
  • [25] Global and local inhomogeneity indices of lung ventilation based on electrical impedance tomography
    Zhao, Z.
    Moeller, K.
    Steinmann, D.
    Guttmann, J.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 256 - 259
  • [26] Flexible tactile sensing of magnetic hydrogel composites based on electrical impedance tomography
    Li, Bin
    Yang, Xuanxuan
    Chen, Haofeng
    Xu, Chanchan
    Wang, Xiaojie
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2024,
  • [27] Comparison of jugular and transverse facial venous sinus blood analytes in healthy and critically ill adult horses
    Lascola, Kara M.
    Vander Werf, Karie
    Freese, Stephanie
    Morgera, Alison
    Schaeffer, David J.
    Wilkins, Pamela
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2017, 27 (02) : 198 - 205
  • [28] Breath-by-breath assessment of acute pulmonary edema using electrical impedance tomography, spirometry and volumetric capnography in a sheep (Ovis Aries) model
    Raisis, Anthea
    Mosing, Martina
    Sacks, Muriel
    Hosgood, Giselle
    Schramel, Johannes
    Blumer, Sarah
    Boehm, Stephan H.
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11
  • [29] Regional distribution of ventilation in horses in dorsal recumbency during spontaneous and mechanical ventilation assessed by electrical impedance tomography: a case series
    Mosing, Martina
    Marly-Voquer, Charlotte
    MacFarlane, Paul
    Bardell, David
    Bohm, Stephan H. B.
    Bettschart-Wolfensberger, Regula
    Waldmann, Andreas D.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (01) : 127 - 132
  • [30] Electrical Impedance Tomography-based Ventilation Patterns in Patients after Major Surgery
    Iwata, Hirofumi
    Yoshida, Takeshi
    Hoshino, Taiki
    Aiyama, Yuki
    Maezawa, Takashi
    Hashimoto, Haruka
    Koyama, Yukiko
    Yamada, Tomomi
    Fujino, Yuji
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209 (11) : 1328 - 1337