Calibrating and Validating the MFI-UF Method to Measure Particulate Fouling in Reverse Osmosis

被引:0
|
作者
Abunada, Mohanad [1 ,2 ]
Dhakal, Nirajan [1 ]
Andyar, William Z. [1 ]
Li, Yuke [1 ]
Ajok, Pamela [1 ]
Ghaffour, Noreddine [3 ]
Schippers, Jan C. [1 ]
Kennedy, Maria D. [1 ,2 ]
机构
[1] IHE Delft Inst Water Educ, Water Supply Sanitat & Environm Engn Dept, Westvest 7, NL-2611 AX Delft, Netherlands
[2] Delft Univ Technol, Fac Civil Engn, Stevinweg 1, NL-2628 CN Delft, Netherlands
[3] King Abdullah Univ Sci & Technol KAUST, Water Desalinat & Reuse Ctr WDRC, Biol & Environm Sci & Engn BESE Div, Thuwal 239556900, Saudi Arabia
关键词
reverse osmosis; particulate fouling; MFI-UF; calibration; linearity; CONSTANT FLUX; INDEX; SYSTEMS;
D O I
10.3390/membranes13050535
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study aimed to calibrate and validate the MFI-UF method in order to ensure the accuracy of particulate fouling measurements in RO. Firstly, the MFI-UF calibration was examined using two solutions of standard particles (dextran and polystyrene). Two main criteria were investigated: (i) MFI-UF linearity with particle concentrations at both low and high ranges of fouling potential and (ii) the reproducibility of MFI-UF linearity. Dextran solutions showed a strong MFI-UF linearity over the entire range of measured MFI-UF. However, the linearity was not reproducible, and different batches of dextran prepared under the same conditions produced very variable results. For polystyrene solutions, the MFI-UF linearity was verified at the higher range of MFI-UF (>10,000 s/L-2), while the MFI-UF at the lower range (<5000 s/L-2) appeared to be underestimated. Secondly, MFI-UF linearity was investigated using natural (surface) water under a wide range of testing conditions (at 20-200 L/m(2) center dot h using 5-100 kDa membranes). Strong MFI-UF linearity was obtained over the entire range of measured MFI-UF (up to 70,000 s/L-2). Thus, the MFI-UF method was validated to measure different levels of particulate fouling in RO. However, future research focusing on MFI-UF calibration is still required through the selection, preparation, and testing of heterogeneous mixtures of standard particles.
引用
收藏
页数:13
相关论文
共 19 条
  • [1] Applications of the MFI-UF to measure and predict particulate fouling in RO systems
    Boerlage, SFE
    Kennedy, M
    Aniye, MP
    Schippers, JC
    JOURNAL OF MEMBRANE SCIENCE, 2003, 220 (1-2) : 97 - 116
  • [2] Prediction of particulate fouling in full-scale reverse osmosis plants using the modified fouling index-ultrafiltration (MFI-UF) method
    Abunada, Mohanad
    Dhakal, Nirajan
    Gulrez, Raffay
    Ajok, Pamela
    Li, Yuke
    Abushaban, Almotasembellah
    Smit, Herman
    Moed, David
    Ghaffour, Noreddine
    Schippers, Jan C.
    Kennedy, Maria D.
    DESALINATION, 2023, 553
  • [3] Application of MFI-UF fouling index with NOM fouling under various operating conditions
    Alresheedi, Mohammad T.
    Basu, Onita D.
    DESALINATION AND WATER TREATMENT, 2018, 133 : 45 - 54
  • [4] Comparison of MFI-UF constant pressure, MFI-UF constant flux and Crossflow Sampler-Modified Fouling Index Ultrafiltration (CFS-MFIUF)
    Sim, Lee Nuang
    Ye, Yun
    Chen, Vicki
    Fane, Anthony G.
    WATER RESEARCH, 2011, 45 (04) : 1639 - 1650
  • [5] Improving MFI-UF constant flux to more accurately predict particulate fouling in RO systems: Quantifying the effect of membrane surface porosity
    Abunada, Mohanad
    Dhakal, Nirajan
    Andyar, William Z.
    Ajok, Pamela
    Smit, Herman
    Ghaffour, Noreddine
    Schippers, Jan C.
    Kennedy, Maria D.
    JOURNAL OF MEMBRANE SCIENCE, 2022, 660
  • [6] The modified fouling index using ultrafiltration membranes (MFI-UF): characterisation, filtration mechanisms and proposed reference membrane
    Boerlage, SFE
    Kennedy, MD
    Dickson, MR
    El-Hodali, DEY
    Schippers, JC
    JOURNAL OF MEMBRANE SCIENCE, 2002, 197 (1-2) : 1 - 21
  • [7] EFFECTS OF ACCELERATION ON PARTICULATE FOULING IN REVERSE-OSMOSIS
    EID, JC
    ANDEEN, GB
    DESALINATION, 1983, 47 (MAY) : 191 - 199
  • [8] Flux dependency of particulate/colloidal fouling in seawater reverse osmosis systems
    Rodriguez, Sergio Genaro Salinas
    Kennedy, Maria Dolores
    Amy, Gary Lee
    Schippers, Jan Cornelis
    DESALINATION AND WATER TREATMENT, 2012, 42 (1-3) : 155 - 162
  • [9] A more effective method for fouling characterization in a full-scale reverse osmosis process
    Tay, KG
    Song, LF
    DESALINATION, 2005, 177 (1-3) : 95 - 107
  • [10] A simplified method for the quantification of fouling on reverse osmosis membranes: implication for the selection of effective cleaning chemicals
    Orbaum, Naomi
    Serlin, Linor
    Lakretz-Mashiah, Anat
    Brover, Semion
    Sahar-Hadar, Eyal
    Lester, Yaal
    DESALINATION AND WATER TREATMENT, 2020, 194 : 52 - 58