Ultra-high resolution photon-counting coronary CT angiography improves coronary stenosis quantification over a wide range of heart rates-A dynamic phantom study

被引:34
作者
Zsarnoczay, Emese [1 ,2 ]
Fink, Nicola [1 ,3 ]
Schoepf, U. Joseph [1 ,9 ]
O'Doherty, Jim [1 ,4 ]
Allmendinger, Thomas [5 ]
Hagenauer, Junia [5 ,6 ]
Wolf, Elias, V [1 ,7 ]
Griffith III, Joseph P. [1 ]
Maurovich-Horvat, Pal [2 ]
Varga-Szemes, Akos [1 ]
Emrich, Tilman [1 ,7 ,8 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, 25 Courtenay Dr, Charleston, SC 29425 USA
[2] Semmelweis Univ, Med Imaging Ctr, MTA SE Cardiovasc Imaging Res Grp, Korany Sandor Utca 2, H-1083 Budapest, Hungary
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Marchioninist 15, D-81377 Munich, Germany
[4] Siemens Med Solut USA Inc, 40 Liberty Blvd, Malvern, PA 19355 USA
[5] Siemens Healthcare GmbH, Siemensstr 1, D-91301 Forchheim, Germany
[6] Friedrich Alexander Univ Erlangen Nuremberg, Fac Med, Krankenhausstr 12, D-91054 Erlangen, Germany
[7] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, Langenbeckstr 1, D-55131 Mainz, Germany
[8] German Ctr Cardiovasc Res, Partner Site Rhine Main, D-55131 Mainz, Germany
[9] Med Univ South Carolina, Dept Radiol & Radiol Sci, Ashley River Tower,25 Courtenay Dr, Charleston, SC 29425 USA
关键词
Photon counting detector; Computed tomography angiography; Cardiac imaging techniques; Coronary artery disease; COMPUTED-TOMOGRAPHY; CLINICAL-APPLICATIONS; ARTERY STENOSES; ALGORITHM;
D O I
10.1016/j.ejrad.2023.110746
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the effect of using photon-counting detector (PCD)-CT with ultra-high resolution (UHR) on stenosis quantification accuracy and blooming artifacts from low to high heart rates in a dynamic motion phantom.Method: Two vessel phantoms (diameter: 4 mm) containing solid calcified lesions (25%, 50% stenoses), filled with different concentrations of iodine, inside an anthropomorphic thorax phantom attached to a coronary motion simulator were used. Scanning was performed on a PCD-CT system using an ECG-gated mode at UHR and standard resolution (SR) (0.2, 0.6 mm slice thickness, respectively). Images were reconstructed at 60, 80 and 100 beats per minute (bpm) (UHR: Bv56 kernel, quantum iterative reconstruction (QIR) level 3; SR: 55 keV, Bv40 kernel, QIR3). Percent diameter stenosis (PDS) and blooming artifacts were measured by two readers.Results: PDS measurements derived from UHR were more accurate than SR for both lesions at every heart rate (p <= 0.005 for all, e.g. 50% lesion SR vs. UHR: at 60 bpm 57.1% [55.2-59.2] vs. 50.0% [48.5-51.2], at 100 bpm 61.0% [58.6-64.3] vs. 52.4% [51.3-54.3]). Overall mean difference across heart rates and lesions compared to the nominal stenoses was 9.2% (Limit of Agreement (LoA), 2.4%/16.0%) for SR vs. 2.4% (LoA, -2.8%/7.5%) for UHR. Blooming artifacts decreased with UHR compared to SR for both lesions at every heart rate (p < 0.001 for all, e.g. 50% lesion SR vs. UHR: at 60 bpm 63.8% [60.6-69.5] vs. 52.5% [50.0-57.5], at 100 bpm 70.2% [64.8-78.1] vs. 56.1% [51.2-60.8]). Conclusions: This motion phantom study demonstrates improved stenosis quantification accuracy and reduced blooming artifacts with UHR-PCD-CT compared to SR, independent of heart rate.
引用
收藏
页数:7
相关论文
共 32 条
[1]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]   Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm Assessment Using a Cardiac Motion Phantom [J].
Allmendinger, Thomas ;
Nowak, Tristan ;
Flohr, Thomas ;
Klotz, Ernst ;
Hagenauer, Junia ;
Alkadhi, Hatem ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2022, 57 (06) :399-405
[4]   A New Frontier in Temporal Bone Imaging: Photon-Counting Detector CT Demonstrates Superior Visualization of Critical Anatomic Structures at Reduced Radiation Dose [J].
Benson, J. C. ;
Rajendran, K. ;
Lane, J. I. ;
Diehn, F. E. ;
Weber, N. M. ;
Thorne, J. E. ;
Larson, N. B. ;
Fletcher, J. G. ;
McCollough, C. H. ;
Leng, S. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, :579-584
[5]   Contemporary Discrepancies of Stenosis Assessment by Computed Tomography and Invasive Coronary Angiography Analysis of the CORE320 International Study [J].
Bin Song, Young ;
Arbab-Zadeh, Armin ;
Matheson, Matthew B. ;
Ostovaneh, Mohammad R. ;
Vavere, Andrea L. ;
Dewey, Marc ;
Rochitte, Carlos ;
Niinuma, Hiroyuki ;
Laham, Roger ;
Schuijf, Joanne D. ;
Cox, Christopher ;
Brinker, Jeffrey ;
di Carli, Marcelo ;
Lima, Joao A. C. ;
Miller, Julie M. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (02)
[6]   First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography [J].
Boccalini, Sara ;
Si-Mohamed, Salim A. ;
Lacombe, Hugo ;
Diaw, Adja ;
Varasteh, Mohammad ;
Rodesch, Pierre-Antoine ;
Villien, Marjorie ;
Sigovan, Monica ;
Dessouky, Riham ;
Coulon, Philippe ;
Yagil, Yoad ;
Lahoud, Elias ;
Erhard, Klaus ;
Rioufol, Gilles ;
Finet, Gerard ;
Bonnefoy-Cudraz, Eric ;
Bergerot, Cyrille ;
Boussel, Loic ;
Douek, Philippe C. .
INVESTIGATIVE RADIOLOGY, 2022, 57 (04) :212-221
[7]   Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications [J].
D'Angelo, Tommaso ;
Cicero, Giuseppe ;
Mazziotti, Silvio ;
Ascent, Giorgio ;
Albrecht, Moritz H. ;
Martin, Simon S. ;
Othman, Ahmed E. ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1098)
[8]  
Emrich T., 2022, INVEST RADIOL, DOI [10.1097/RLI.0000000000000911, DOI 10.1097/RLI.0000000000000911]
[9]   Coronary Computed Tomography Angiography-Based Calcium Scoring In Vitro and In Vivo Validation of a Novel Virtual Noniodine Reconstruction Algorithm on a Clinical, First-Generation Dual-Source Photon Counting-Detector System [J].
Emrich, Tilman ;
Aquino, Gilberto ;
Schoepf, U. Joseph ;
Braun, Franziska M. ;
Risch, Franka ;
Bette, Stefanie J. ;
Woznicki, Piotr ;
Decker, Josua A. ;
O'Doherty, Jim ;
Brandt, Verena ;
Allmendinger, Thomas ;
Nowak, Tristan ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Kroencke, Thomas J. ;
Scheurig-Muenkler, Christian ;
Varga-Szemes, Akos ;
Schwarz, Florian .
INVESTIGATIVE RADIOLOGY, 2022, 57 (08) :536-543
[10]   Review of Technical Advancements and Clinical Applications of Photon-counting Computed Tomography in Imaging of the Thorax [J].
Farhadi, Faraz ;
Rajagopal, Jayasai R. ;
Nikpanah, Moozhan ;
Sahbaee, Pooyan ;
Malayeri, Ashkan A. ;
Pritchard, William F. ;
Samei, Ehsan ;
Jones, Elizabeth C. ;
Chen, Marcus Y. .
JOURNAL OF THORACIC IMAGING, 2021, 36 (02) :84-94