ECG Signals Segmentation Using Deep Spatiotemporal Feature Fusion U-Net for QRS Complexes and R-Peak Detection

被引:13
|
作者
Peng, Xiangdong [1 ]
Zhu, Huaqiang [1 ]
Zhou, Xiao [1 ]
Pan, Congcheng [1 ]
Ke, Zejun [1 ]
机构
[1] Jiangxi Univ Finance & Econ, Sch Software & Internet Things Engn, Nanchang 330013, Peoples R China
关键词
Electrocardiography; Feature extraction; Databases; Heart beat; Noise reduction; Spatiotemporal phenomena; Training; Electrocardiogram (ECG); QRS complexes detection; R-peak; residual path; spatiotemporal features; U-net; AUTOMATIC DETECTION; NEURAL-NETWORK; CLASSIFICATION;
D O I
10.1109/TIM.2023.3241997
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To detect and identify QRS complexes and R-peak is one of the crucial steps in the field of electrocardiogram (ECG) signals research, and their detection accuracy directly affects the performance of the subsequent ECG signal processing and analysis. However, the task involving the detection and identification of the ECG features becomes so complex for the traditional threshold-based detection methods. At present, researchers turn to deep learning (DL) approaches, but little work has been done on the detection of spatiotemporal features of the QRS complexes. In this article, for better QRS complexes and R-peak detection, we propose a novel method based on the improved U-net model, called ST-Res U-net. This uniquely designed component of the improved U-net model is made up of four levels of ST block (the block extracting spatial-temporal features) and Res Path (the residual path). The entire framework contains three steps: data preprocessing dealing with denoising of the raw ECG signals, the key component ST-Res U-net dealing with the spatiotemporal feature extraction, and a threshold screening algorithm for locating the R-peaks. Our experiments are purposely designed to test various combination structures of the ST blocks. The training and testing are from the MIT-BIH arrhythmia database (MITDB) and the CPSC2019 database. We adopt a commonly used set of evaluation criteria with the following experimental results: 99.76% and 90.01% for sensitivity, 99.87% and 93.5% for positive predictivity rate, 99.81% and 91.75% for F1 value, and 0.37% and 15.24% for detection error rate (DER). The former numbers are for MITDB and the latter CPSC2019. Furthermore, we test the proposed method on the PTB-XL database (without labeled R-peak positions), and the method can accurately locate QRS complexes and R-peaks The experimental results demonstrate that the proposed model and method is quite effective for the automatic classification and annotation of ECG signals and thus greatly improves the accuracy of diagnosis of arrhythmia diseases.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] U-Net Based Fetal R-peak Prediction From Abdominal ECG Signals
    Zhou, Peishan
    Schwerin, Belinda
    So, Stephen
    2024 9TH INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING, ICSIP, 2024, : 121 - 125
  • [2] QRS detection of ECG signal using U-Net and DBSCAN
    Wang, Huiqian
    He, Sijia
    Liu, Ting
    Pang, Yu
    Lin, Jinzhao
    Liu, Qinghui
    Han, Kaining
    Wang, Junchao
    Jeon, Gwanggil
    MULTIMEDIA TOOLS AND APPLICATIONS, 2022, 81 (10) : 13319 - 13333
  • [3] QRS detection of ECG signal using U-Net and DBSCAN
    Huiqian Wang
    Sijia He
    Ting Liu
    Yu Pang
    Jinzhao Lin
    Qinghui Liu
    Kaining Han
    Junchao Wang
    Gwanggil Jeon
    Multimedia Tools and Applications, 2022, 81 : 13319 - 13333
  • [4] R-peak Detection of ECG using Adaptive Thresholding
    Aurobinda, Anushree
    Mohanty, Bibhu Prasad
    Mohanty, Mihir Narayan
    2016 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), VOL. 1, 2016, : 284 - 287
  • [5] R-PEAK DETECTION IN ECG IMAGES USING MATLAB®
    Verma, Aditya
    Teja, Kakanuru Siva
    Puntambekar, Viraj
    Rajini, G. K.
    ICAIP 2018: 2018 THE 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN IMAGE PROCESSING, 2018, : 11 - 14
  • [6] NN-Based R-peak Detection in QRS Complex of ECG Signal
    Hasan, M. A.
    Ibrahimy, M. I.
    Reaz, M. B. I.
    4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 217 - 220
  • [7] Robust ECG R-peak Detection Using LSTM
    Laitala, Juho
    Jiang, Mingzhe
    Syrjala, Elise
    Naeini, Emad Kasaeyan
    Airola, Antti
    Rahmani, Amir M.
    Dutt, Nikil D.
    Liljeberg, Pasi
    PROCEEDINGS OF THE 35TH ANNUAL ACM SYMPOSIUM ON APPLIED COMPUTING (SAC'20), 2020, : 1104 - 1111
  • [8] A Novel Method for R-peak Detection in Noisy ECG Signals Using EEMD and ICA
    Safari, Amirhossein
    Hesar, Hamed Danandeh
    Mohebbi, Maryam
    Faradji, Farhad
    2016 23RD IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING AND 2016 1ST INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2016, : 150 - 153
  • [9] Improved ICA algorithm for ECG feature extraction and R-peak detection
    Jayasanthi, M.
    Ramamoorthy, V.
    Parthiban, A.
    INTERNATIONAL JOURNAL OF ADAPTIVE CONTROL AND SIGNAL PROCESSING, 2021, 35 (01) : 38 - 50
  • [10] Application of the R-peak detection algorithm for locating noise in ECG signals
    Tomas, Bozo
    Grabovac, Mijo
    Tomas, Karlo
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 72