In Silico Finite Element Analysis of Implant-Supported CAD-CAM Resin Composite Crowns

被引:8
|
作者
Karaer, Oguzcan [1 ]
Yamaguchi, Satoshi [2 ]
Imazato, Satoshi [2 ]
Terzioglu, Hakan [1 ]
机构
[1] Ankara Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
[2] Osaka Univ, Dept Biomat Sci, Grad Sch Dent, Osaka, Japan
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2023年 / 32卷 / 03期
基金
日本学术振兴会;
关键词
CAD-CAM; dental implant; elastic modulus; finite element analysis; three-point bending test; ALL-CERAMIC RESTORATIONS; STRESS-DISTRIBUTION; BONE; SURVIVAL; BLOCKS; PROSTHESIS; BEHAVIOR; QUALITY; FILLER;
D O I
10.1111/jopr.13531
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose The aim of this study was to evaluate the mechanical behavior of an implant-supported crown made using computer-aided design and computer-aided manufacturing (CAD-CAM) resin composite (RC) blocks in the posterior region. Material and methods Four commercially available CAD-CAM RC blocks were used in this study: Cerasmart 300 (CS300; GC, Tokyo, Japan), Katana Avencia P Block (KAP; Kuraray Noritake Dental, Niigata, Japan); KZR HR3 Gamma Theta (HR3; Yamakin, Osaka, Japan), and Estelite P block (ESP; Tokuyama Dental, Tokyo, Japan). Katana Zirconia STML (ST; Kuraray Noritake Dental) was used as the control group. The elastic moduli of each material were determined by a three-point bending test. After the CAD models were designed, two different loading scenarios (oblique, vertical) were created. 3D finite element analysis was conducted with the prepared models. Results The elastic modulus of the material utilized for the implant restorations did not cause any change in the stresses transmitted to the implant or peripheral bone. An important difference was detected in the abutment-crown junction area. The minimum von Mises value at the abutment-crown interface was obtained in ST, which has the closest elastic modulus to the titanium abutment. Conclusions The 3D finite element model designed in this study was used to demonstrate that implant-supported crowns fabricated with four different CAD-CAM RCs showed no critical stress concentrations in the bone or implant under all loading conditions. These results suggest that CAD-CAM RC blocks could be used as an alternative material for implant-supported restorations in the posterior region in terms of stress distribution.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 50 条
  • [31] Fabrication of an implant-supported overdenture using CAD/CAM technology: A clinical report
    Rinke, Sven
    Ziebolz, Dirk
    QUINTESSENCE INTERNATIONAL, 2013, 44 (02): : 127 - 134
  • [32] SHOULD ORAL IMPLANTS BE SPLINTED IN A MANDIBULAR IMPLANT-SUPPORTED FIXED COMPLETE DENTURE? A 3-DIMENSIONAL-MODEL FINITE ELEMENT ANALYSIS
    Alvarez-Arenal, Angel
    Brizuela-Velasco, Aritza
    DeLlanos-Lanchares, Hector
    Gonzalez-Gonzalez, Ignacio
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03) : 508 - 514
  • [33] Effect of Different Framework Materials in Implant-Supported Fixed Mandibular Prostheses: A Finite Element Analysis
    Sirandoni, Diego
    Leal, Eduardo
    Weber, Benjamin
    Noritomi, Pedro Yoshito
    Fuentes, Ramon
    Borie, Eduardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (06) : E107 - E114
  • [34] Fracture strength of various titanium-based, CAD-CAM and PFM implant crowns
    DuVall, Nicholas B.
    DeReis, Stephen P.
    Vandewalle, Kraig S.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2021, 33 (03) : 522 - 530
  • [35] Three-dimensional finite element analysis of implant-supported crown in fibula bone model
    Park, Young-Seok
    Kwon, Ho-Beom
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (03) : 326 - 332
  • [36] Misfit of Implant-Supported Zirconia (Y-TZP) CAD-CAM Framework Compared to Non-Zirconia Frameworks: A Systematic Review
    Alsayed, Hussain D.
    MEDICINA-LITHUANIA, 2022, 58 (10):
  • [38] Biomechanical Evaluation of Different Implant-Abutment Connections, Retention Systems, and Restorative Materials in the Implant-Supported Single Crowns Using 3D Finite Element Analysis
    Araujo Lemos, Cleidiel Aparecido
    Verri, Fellippo Ramos
    Noritomi, Pedro Yoshito
    de Souza Batista, Victor Eduardo
    Cruz, Ronaldo Silva
    de Luna Gomes, Jessica Marcela
    Justino de Oliveira Limirio, Joao Pedro
    Pellizzer, Eduardo Piza
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (03) : 194 - 201
  • [39] Fracture load of zirconia implant supported CAD/CAM resin crowns and mechanical properties of restorative material and cement
    Rohr, Nadja
    Martin, Sabrina
    Fischer, Jens
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (04) : 502 - 508
  • [40] Application of the functionally generated path technique in designing an implant-supported fixed prosthesis with CAD-CAM technology: A dental technique
    Park, Seong-gi
    Kim, Manyong
    Yoo, Jin-joo
    Yoon, Joon-Ho
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (05) : 667 - 670