Predicting per- and polyfluoroalkyl substances removal in pilot-scale granular activated carbon adsorbers from rapid small-scale column tests

被引:3
作者
Hopkins, Zachary R. [1 ]
Knappe, Detlef R. U. [1 ]
机构
[1] North Carolina State Univ, Dept Civil Construct & Environm Engn, Raleigh, NC 27695 USA
来源
AWWA WATER SCIENCE | 2024年 / 6卷 / 02期
关键词
hexafluoropropylene oxide-dimer acid (HFPO-DA; GenX); perfluorooctane sulfonate (PFOS); perfluorooctanoic acid (PFOA); remediation; DRINKING-WATER CONTAMINANTS; PERFLUOROALKYL SUBSTANCES; ADSORPTION TESTS; IN-SOURCE; PFASS; DESIGN; ACIDS; RIVER; GAC;
D O I
10.1002/aws2.1369
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Per- and polyfluoroalkyl substances (PFAS) occur widely in drinking water, and consumption of contaminated drinking water is an important human exposure route. Granular activated carbon (GAC) adsorption can effectively remove PFAS from water. To support the design of GAC treatment systems, a rapid bench-scale testing procedure and scale-up approach are needed to assess the effects of GAC type, background water matrix, and empty bed contact time (EBCT) on GAC use rates. The overarching goal of this study was to predict PFAS breakthrough curves obtained at the pilot-scale from rapid small-scale column test (RSSCT) data. The scale-up protocol was developed for pilot data obtained with coagulated/settled surface water (TOC = 2.3 mg/L), three GACs, and two EBCTs. Between 7 and 11 PFAS breakthrough curves were available for each pilot column. RSSCT designs were investigated that assumed intraparticle diffusivity is independent of GAC particle size (i.e., constant diffusivity [CD]) or linearly dependent on GAC particle size (i.e., proportional diffusivity [PD]). CD-RSSCTs effectively predicted the bed volumes of water that could be treated at the pilot-scale to reach 50% breakthrough (BV50%) of individual PFAS. In contrast, PD-RSSCTs overpredicted BV50% obtained at the pilot-scale by a factor of similar to 2-3. The shape of PFAS breakthrough curves obtained with CD-RSSCTs deviated from those obtained at the pilot-scale, indicating that intraparticle diffusivity was dependent on GAC particle diameter (d(p)). Using the pore surface diffusion model (PSDM), intraparticle diffusivity was found to be proportional to (d(p))(0.25) when considering data up to about 70% PFAS breakthrough. This proportionality factor can be used to design RSSCTs or scale up existing CD-RSSCT data using the PSDM. Using pilot-scale data obtained with groundwater and wastewater-impacted groundwater as well as with additional GACs, the developed RSSCT scale-up approach was validated for PFAS breakthrough percentages up to 70%. The presented methodology permits the rapid prediction of GAC use rates for PFAS removal.
引用
收藏
页数:15
相关论文
共 48 条
  • [1] [Anonymous], 2022, Drinking Water Health Advisories for PFOA and PFOS
  • [2] [Anonymous], 2023, PFAS National Primary Drinking Water Regulation Rulemaking: Proposed Rule
  • [3] Treatment of poly- and perfluoroalkyl substances in US full-scale water treatment systems
    Appleman, Timothy D.
    Higgins, Christopher P.
    Quinones, Oscar
    Vanderford, Brett J.
    Kolstad, Chad
    Zeigler-Holady, Janie C.
    Dickenson, Eric R. V.
    [J]. WATER RESEARCH, 2014, 51 : 246 - 255
  • [4] Berrigan J.K., 1985, Scale-up of rapid small-scale adsorption tests to fixed-scale adsorbers: Theoretical and experimental basis
  • [5] Per- and polyfluoroalkyl substances in source and treated drinking waters of the United States
    Boone, J. Scott
    Vigo, Craig
    Boone, Tripp
    Byrne, Christian
    Ferrario, Joseph
    Benson, Robert
    Donohue, Joyce
    Simmons, Jane Ellen
    Kolpin, Dana W.
    Furlong, Edward T.
    Glassmeyer, Susan T.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 653 : 359 - 369
  • [6] Short-chain perfluoroalkyl acids: environmental concerns and a regulatory strategy under REACH
    Brendel, Stephan
    Fetter, Eva
    Staude, Claudia
    Vierke, Lena
    Biegel-Engler, Annegret
    [J]. ENVIRONMENTAL SCIENCES EUROPE, 2018, 30
  • [7] Removal of Per- and Polyfluoroalkyl substances by anion exchange resins: Scale-up of rapid small-scale column test data
    Cheng, Lan
    Knappe, Detlef R. U.
    [J]. WATER RESEARCH, 2024, 249
  • [8] Adsorption and desorption of trace organic contaminants from granular activated carbon adsorbers after intermittent loading and throughout backwash cycles
    Corwin, Christopher J.
    Summers, R. Scott
    [J]. WATER RESEARCH, 2011, 45 (02) : 417 - 426
  • [9] Scaling Trace Organic Contaminant Adsorption Capacity by Granular Activated Carbon
    Corwin, Christopher J.
    Summers, R. Scott
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (14) : 5403 - 5408
  • [10] The concept of essential use for determining when uses of PFASs can be phased out
    Cousins, Ian T.
    Goldenman, Gretta
    Herzke, Dorte
    Lohmann, Rainer
    Miller, Mark
    Ng, Carla A.
    Patton, Sharyle
    Scheringer, Martin
    Trier, Xenia
    Vierke, Lena
    Wang, Zhanyun
    DeWitt, Jamie C.
    [J]. ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2019, 21 (11) : 1803 - 1815