The value of a deep learning image reconstruction algorithm in whole-brain computed tomography perfusion in patients with acute ischemic stroke

被引:7
作者
Lei, Limin [1 ]
Zhou, Yuhan [1 ]
Guo, Xiaoxu [1 ]
Wang, Luotong [2 ]
Zhao, Xitong [1 ]
Wang, Hui [1 ]
Ma, Jinping [1 ]
Yue, Songwei [1 ,3 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Radiol, Zhengzhou, Peoples R China
[2] GE HealthCare China, Beijing, Peoples R China
[3] Zhengzhou Univ, Affiliated Hosp 1, Dept Radiol, 1 Jianshe East Rd, Zhengzhou 450052, Peoples R China
关键词
Deep learning image reconstruction algorithm (DLIR algorithm); computed tomography perfusion; (CTP); reconstructed CT angiography; image quality; acute ischemic stroke (AIS); RADIATION-DOSE REDUCTION; CT PERFUSION; VOLUME; THROMBECTOMY; PERFORMANCE; SELECTION;
D O I
10.21037/qims-23-547
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Computed tomography perfusion (CTP) and computed tomography angiography (CTA) are valuable tools for diagnosing acute ischemic stroke (AIS). It is essential to obtain high-quality CTP and CTA images in short time. This study aimed to evaluate the image quality and diagnostic performance of brain CTP and CTA images generated from CTP reconstructed by a deep learning image reconstruction (DLIR) algorithm on patients with AIS. Methods: The study prospectively enrolled 54 patients with suspected AIS undergoing non-contrast CT and CTP within 24 hours. CTP datasets were reconstructed with three levels of adaptive statistical iterative reconstruction-Veo algorithm [ASIR-V 0% with filtered back projection (FBP), ASIR-V 40%, and ASIR-V 80%] and three levels of DLIR, including low (DLIR-L), medium (DLIR-M), and high (DLIR-H). CTA images were generated using the CTP datasets at the peak arterial phase. Objective parameters including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and noise reduction rate. Subjective evaluation was assessed according to Abels scoring system. Perfusion parameters and detection accuracy for infarction core lesions were evaluated. The objective and subjective image quality of CTA images were also evaluated. Results: All reconstructions produced similar CT values (P>0.05). With the increase of ASIR-V and DLIR reconstruction strength, image noise decreased, while SNR and CNR increased for CTP images, especially in white matter. DLIR-H, DLIR-M, and ASIR-V80% yielded higher subjective scores than did ASIR-V40% and FBP. DLIR-H provided the highest noise reduction rate and detection accuracy. No significant difference was found in conventional parameters, the volume of infarct core, or ischemic penumbra among the 6 groups (P>0.05). The objective evaluation of reconstructed CTA images was comparable in DLIR-H, DLIR-M, and ASIR-V80% (P>0.05). The subjective scores of the DLIR-H and DLIR-M images were higher than those of the other groups, especially ASIR-V40% and FBP (P<0.05). Conclusions: Compared with FBP and ASIR-V40%, DLIR-H, DLIR-M, and ASIR-V80% improved the overall image quality of CTP and CTA images to varying degrees. Furthermore, DLIR-H and DLIR-M showed the best performance. DLIR-H is the best choice in diagnosing AIS with improved detection accuracy for cerebral infarction. Reconstructing CTA images using CTP datasets could reduce contrast agent and radiation dose.
引用
收藏
页码:8173 / 8189
页数:17
相关论文
共 38 条
[1]   Diagnostic performance of CT cerebral blood volume colour maps for evaluation of acute infarcts; comparison with diffusion-weighted MRI within 12 hours of major stroke onset [J].
Abdelgawad, Enas A. ;
Higazi, Mahmoud M. ;
Abdelbaky, Abdelraouf O. ;
Abdelghany, Hosny S. .
JOURNAL OF NEURORADIOLOGY, 2017, 44 (01) :10-16
[2]   CT Perfusion in Acute Ischemic Stroke: A Comparison of 2-Second and 1-Second Temporal Resolution [J].
Abels, B. ;
Klotz, E. ;
Tomandl, B. F. ;
Villablanca, J. P. ;
Kloska, S. P. ;
Lell, M. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) :1632-1639
[3]   Deep learning versus iterative image reconstruction algorithm for head CT in trauma [J].
Alagic, Zlatan ;
Cardenas, Jacqueline Diaz ;
Halldorsson, Kolbeinn ;
Grozman, Vitali ;
Wallgren, Stig ;
Suzuki, Chikako ;
Helmenkamp, Johan ;
Koskinen, Seppo K. .
EMERGENCY RADIOLOGY, 2022, 29 (02) :339-352
[4]   Thrombectomy for Stroke at 6 to 16 Hours with Selection by Perfusion Imaging [J].
Albers, G. W. ;
Marks, M. P. ;
Kemp, S. ;
Christensen, S. ;
Tsai, J. P. ;
Ortega-Gutierrez, S. ;
McTaggart, R. A. ;
Torbey, M. T. ;
Kim-Tenser, M. ;
Leslie-Mazwi, T. ;
Sarraj, A. ;
Kasner, S. E. ;
Ansari, S. A. ;
Yeatts, S. D. ;
Hamilton, S. ;
Mlynash, M. ;
Heit, J. J. ;
Zaharchuk, G. ;
Kim, S. ;
Carrozzella, J. ;
Palesch, Y. Y. ;
Demchuk, A. M. ;
Bammer, R. ;
Lavori, P. W. ;
Broderick, J. P. ;
Lansberg, M. G. .
NEW ENGLAND JOURNAL OF MEDICINE, 2018, 378 (08) :708-718
[5]   Radiation dose reduction with deep-learning image reconstruction for coronary computed tomography angiography [J].
Benz, Dominik C. ;
Ersoezlue, Sara ;
Mojon, Francois L. A. ;
Messerli, Michael ;
Mitulla, Anna K. ;
Ciancone, Domenico ;
Kenkel, David ;
Schaab, Jan A. ;
Gebhard, Catherine ;
Pazhenkottil, Aju P. ;
Kaufmann, Philipp A. ;
Buechel, Ronny R. .
EUROPEAN RADIOLOGY, 2022, 32 (04) :2620-2628
[6]   Tenecteplase versus Alteplase before Thrombectomy for Ischemic Stroke [J].
Campbell, B. C. V. ;
Mitchell, P. J. ;
Churilov, L. ;
Yassi, N. ;
Kleinig, T. J. ;
Dowling, R. J. ;
Yan, B. ;
Bush, S. J. ;
Dewey, H. M. ;
Thijs, V. ;
Scroop, R. ;
Simpson, M. ;
Brooks, M. ;
Asadi, H. ;
Wu, T. Y. ;
Shah, D. G. ;
Wijeratne, T. ;
Ang, T. ;
Miteff, F. ;
Levi, C. R. ;
Rodrigues, E. ;
Zhao, H. ;
Salvaris, P. ;
Garcia-Esperon, C. ;
Bailey, P. ;
Rice, H. ;
de Villiers, L. ;
Brown, H. ;
Redmond, K. ;
Leggett, D. ;
Fink, J. N. ;
Collecutt, W. ;
Wong, A. A. ;
Muller, C. ;
Coulthard, A. ;
Mitchell, K. ;
Clouston, J. ;
Mahady, K. ;
Field, D. ;
Ma, H. ;
Phan, T. G. ;
Chong, W. ;
Chandra, R. V. ;
Slater, L. -A. ;
Krause, M. ;
Harrington, T. J. ;
Faulder, K. C. ;
Steinfort, B. S. ;
Bladin, C. F. ;
Sharma, G. .
NEW ENGLAND JOURNAL OF MEDICINE, 2018, 378 (17) :1573-1582
[7]  
[陈鹏军 Chen Pengjun], 2020, [中华放射学杂志, Chinese Journal of Radiology], V54, P112
[8]  
[陈钰 Chen Yu], 2023, [放射学实践, Radiologic Practice], V38, P210
[9]   Iterative Reconstruction Improves Both Objective and Subjective Image Quality in Acute Stroke CTP [J].
Flottmann, Fabian ;
Kabath, Jan ;
Illies, Till ;
Schneider, Tanja ;
Buhk, Jan-Hendrik ;
Fiehler, Jens ;
Kemmling, Andre .
PLOS ONE, 2016, 11 (03)
[10]   Temporal averaging angiographic reconstructions from whole-brain CT perfusion for the detection of vasospasm [J].
Gallissot, Felix ;
Lenfant, Marc ;
Thouant, Pierre ;
Haioun, Karim ;
Thay, Anthony ;
Ricolfi, Frederic ;
Comby, Pierre -Olivier .
JOURNAL OF NEURORADIOLOGY, 2023, 50 (03) :333-340