Absolute thermometry of human brown adipose tissue by magnetic resonance with laser polarized 129Xe

被引:3
|
作者
Zhang, Le [1 ,2 ,4 ]
Antonacci, Michael [1 ,2 ,5 ]
Burant, Alex [1 ,2 ,6 ]
Mccallister, Andrew [1 ,2 ]
Kelley, Michele [1 ,2 ]
Bryden, Nicholas [1 ,2 ]
Mchugh, Christian [1 ,2 ]
Atalla, Sebastian [1 ,2 ]
Holmes, Leah [1 ,2 ]
Katz, Laurence [3 ]
Branca, Rosa Tamara [1 ,2 ]
机构
[1] Univ North Carolina Chapel Hill, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[2] Univ North Carolina Chapel Hill, Biomed Res Imaging Ctr, Chapel Hill, NC 27599 USA
[3] Univ North Carolina Chapel Hill, Dept Emergency Med, Chapel Hill, NC 27599 USA
[4] H Lee Moffitt Canc Ctr & Res Inst, Dept Canc Physiol, Small Anim Imaging Lab, Tampa, FL 33612 USA
[5] St Vincent Coll, Dept Phys, 300 Fraser Purchase Rd, Latrobe, PA 15650 USA
[6] Univ Arizona, Dept Phys, 1118 E Fourth St,POB 210081, Tucson, AZ 85721 USA
来源
COMMUNICATIONS MEDICINE | 2023年 / 3卷 / 01期
关键词
DIET-INDUCED THERMOGENESIS; BLOOD-FLOW; TEMPERATURE-DEPENDENCE; HYPERPOLARIZED XE-129; ENERGY-EXPENDITURE; BRAIN TEMPERATURE; FAT; XENON; OBESITY; NMR;
D O I
10.1038/s43856-023-00374-x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background Absolute temperature measurements of tissues inside the human body are difficult to perform non-invasively. Yet, for brown adipose tissue (BAT), these measurements would enable direct monitoring of its thermogenic activity and its association with metabolic health.Methods Here, we report direct measurement of absolute BAT temperature in humans during cold exposure by magnetic resonance (MR) with laser polarized xenon gas. This methodology, which leverages on the sensitivity of the chemical shift of the Xe-129 isotope to temperature-induced changes in fat density, is first calibrated in vitro and then tested in vivo in rodents. Finally, it is used in humans along with positron emission tomography (PET) scans with fluorine-18-fluorodeoxyglucose to detect BAT thermogenic activity during cold exposure.Results Absolute temperature measurements, obtained in rodents with an experimental error of 0.5 C-degrees, show only a median deviation of 0.12(degrees)C against temperature measurements made using a pre-calibrated optical temperature probe. In humans, enhanced uptake of Xe-129 in BAT during cold exposure leads to background-free detection of this tissue by MR. Global measurements of supraclavicular BAT temperature, made over the course of four seconds and with an experimental error ranging from a minimum of 0.4 C-degrees to more than 2 C-degrees, in case of poor shimming, reveal an average BAT temperature of 38.8(degrees) +/- 0.8 C-degrees, significantly higher (p < 0.02 two-sided t test) than 37.7 C-degrees. Hot BAT is also detected in participants with a PET scan negative for BAT.Conclusions Non-invasive, radiation-free measurements of BAT temperature by MRI with hyperpolarized Xe-129 may enable longitudinal monitoring of human BAT activity under various stimulatory conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Magnetic resonance imaging with laser-polarized 129Xe
    Welsh, RC
    Chupp, TE
    Coulter, KP
    Rosen, MS
    Swanson, SD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 402 (2-3): : 461 - 463
  • [2] Direct detection of brown adipose tissue thermogenesis in UCP1-/- mice by hyperpolarized 129Xe MR thermometry
    Antonacci, Michael A.
    McHugh, Christian
    Kelley, Michele
    McCallister, Andrew
    Degan, Simone
    Branca, Rosa T.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [3] Laser-polarized 129Xe NMR and MRI at ultralow magnetic fields
    Wong-Foy, A
    Saxena, S
    Moulé, AJ
    Bitter, HML
    Seeley, JA
    McDermott, R
    Clarke, J
    Pines, A
    JOURNAL OF MAGNETIC RESONANCE, 2002, 157 (02) : 235 - 241
  • [4] An apparatus for NMR of laser polarized 129Xe on single crystal surfaces
    D. Stahl
    H.J. Jänsch
    Hyperfine Interactions, 2000, 127 : 469 - 474
  • [5] Applications of laser-polarized 129Xe under continuous flow
    Brunner, E
    MAGNETIC RESONANCE IN CHEMISTRY, 1999, 37 : S14 - S22
  • [6] Distribution and dynamics of laser-polarized 129Xe magnetization in vivo
    Swanson, SD
    Rosen, MS
    Coulter, KP
    Welsh, RC
    Chupp, TE
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (06) : 1137 - 1145
  • [7] Functionalized 129Xe contrast agents for magnetic resonance imaging
    Taratula, Olena
    Dmochowski, Ivan J.
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2010, 14 (01) : 97 - 104
  • [8] An intracellular diamine oxidase triggered hyperpolarized 129Xe magnetic resonance biosensor
    Zhang, Bin
    Guo, Qianni
    Luo, Qing
    Zhang, Xiaoxiao
    Zeng, QingBin
    Zhao, Longhui
    Yuan, Yaping
    Jiang, Weiping
    Yang, Yunhuang
    Liu, Maili
    Ye, Chaohui
    Zhou, Xin
    CHEMICAL COMMUNICATIONS, 2018, 54 (97) : 13654 - 13657
  • [9] An apparatus for NMR of laser-polarized 129Xe on single crystal surfaces
    Stahl, D
    Jänsch, HJ
    HYPERFINE INTERACTIONS, 2000, 127 (1-4): : 469 - 474
  • [10] Long-distance delivery of laser-polarized 129Xe using a capillary tube
    Asanuma, Tatsuya
    Hiraga, Takashi
    Hattori, Mineyuki
    JOURNAL OF PHYSICS COMMUNICATIONS, 2020, 4 (10):