Telemedicine in the Era of a Pandemic: Usefulness of a Novel Three-Lead ECG

被引:3
作者
Babic, Milos D. D. [1 ]
Veljkovic, Stefan [1 ]
Lakcevic, Jovana [1 ]
Babic, Rade [1 ,2 ]
Ostojic, Miodrag [1 ,2 ]
Petrovic, Masa [1 ,2 ]
Boljevic, Darko [1 ]
Tomic, Stanko [3 ]
Bojic, Milovan [1 ]
Nikolic, Aleksandra [1 ,2 ]
机构
[1] Dedinje Cardiovasc Inst, Belgrade 11000, Serbia
[2] Univ Belgrade, Fac Med, Belgrade 11000, Serbia
[3] Vinca Inst Nucl Sci, Belgrade 11000, Serbia
关键词
electrocardiogram; COVID-19; pandemic; telemedicine; medical devices; signal processing; 12-LEAD ELECTROCARDIOGRAMS; ATRIAL-FIBRILLATION; FEASIBILITY; ACCURACY; REST;
D O I
10.3390/diagnostics13152525
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The 12-lead electrocardiogram (ECG) is a first-line diagnostic tool for patients with cardiac symptoms. As observed during the COVID-19 pandemic, the ECG is essential to the initial patient evaluation. The novel KardioPal three-lead-based ECG reconstructive technology provides a potential alternative to a standard ECG, reducing the response time and cost of treatment and improving patient comfort. Our study aimed to evaluate the diagnostic accuracy of a reconstructed 12-lead ECG obtained by the KardioPal technology, comparing it with the standard 12-lead ECG, and to assess the feasibility and time required to obtain a reconstructed ECG in a real-life scenario. A prospective, nonrandomized, single-center, adjudicator-blinded trial was conducted on 102 patients during the COVID-19 pandemic at the Dedinje Cardiovascular Institute in Belgrade. The KardioPal system demonstrated a high feasibility rate (99%), with high specificity (96.3%), sensitivity (95.8%), and diagnostic accuracy (96.1%) for obtaining clinically relevant matching of reconstructed 12-lead compared to the standard 12-lead ECG recording. This novel technology provided a significant reduction in ECG acquisition time and the need for personnel and space for obtaining ECG recordings, thereby reducing the risk of viral transmission and the burden on an already overwhelmed healthcare system such as the one experienced during the COVID-19 pandemic.
引用
收藏
页数:17
相关论文
共 36 条
[1]  
Ahmed Adnan, 2022, Card Electrophysiol Clin, V14, P115, DOI 10.1016/j.ccep.2021.10.013
[2]  
[Anonymous], 2015, BMJ Innovations, DOI DOI 10.1136/BMJINNOV-2014-000029
[3]   Portable out-of-hospital electrocardiography: A review of current technologies [J].
Bansal, Agam ;
Joshi, Rajnish .
JOURNAL OF ARRHYTHMIA, 2018, 34 (02) :129-138
[4]  
Bhatt A., 2020, AM COLEGE CARDIOL, V24
[5]   Derived 12-lead electrocardiogram in the assessment of ST-segment deviation and cardiac rhythm [J].
Chantad, D ;
Krittayaphong, R ;
Komoltri, C .
JOURNAL OF ELECTROCARDIOLOGY, 2006, 39 (01) :7-12
[6]   Ambulatory Electrocardiographic Monitoring between Artifacts and Misinterpretation, Management Errors of Commission and Errors of Omission [J].
El-Sherif, Nabil ;
Turitto, Gioia .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2015, 20 (03) :282-289
[7]  
Esmel-Vilomara R, 2022, AN PEDIATR, V96, P213, DOI [10.1016/j.anpedi.2021.04.009, 10.1016/j.anpede.2021.04.006]
[8]   Feasibility of Using Mobile ECG Recording Technology to Detect Atrial Fibrillation in Low-Resource Settings [J].
Evans, Grahame F. ;
Shirk, Arianna ;
Muturi, Peter ;
Soliman, Elsayed Z. .
GLOBAL HEART, 2017, 12 (04) :285-289
[9]   Technical Mistakes during the Acquisition of the Electrocardiogram [J].
Garcia-Niebla, Javier ;
Llontop-Garcia, Pablo ;
Ignacio Valle-Racero, Juan ;
Serra-Autonell, Guillem ;
Batchvarov, Velislav N. ;
Bayes de Luna, Antonio .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2009, 14 (04) :389-403
[10]  
George S., 2010, P 15 WORLD C HEART D