Preoperative planning and intraoperative real-time navigation with indocyanine green fluorescence in robotic liver surgery

被引:3
作者
Rompianesi, Gianluca [1 ]
Pegoraro, Francesca [1 ]
Ramaci, Lorenzo [1 ]
Ceresa, Carlo D. L. [2 ]
Montalti, Roberto [3 ]
Troisi, Roberto, I [1 ]
机构
[1] Federico II Univ Hosp, Dept Clin Med & Surg, Div Hepatobiliary Pancreat Minimally Invas & Robot, Via S Pansini 5, Naples, Italy
[2] Univ Oxford, Nuffield Dept Surg Sci, Oxford, England
[3] Federico II Univ Hosp, Div Hepatobiliary Pancreat Minimally Invas & Robot, Dept Publ Hlth, Naples, Italy
关键词
Hepatobiliary surgery; Robotic surgery; Robotic liver resection; Indocyanine green; Intraoperative fluorescence; Preoperative planning; LAPAROSCOPIC CHOLECYSTECTOMY; HEPATECTOMY; RESECTION; CHOLANGIOGRAPHY; ULTRASOUND; RECONSTRUCTION; COMPLICATIONS; EXPERIENCE; OUTCOMES; INDEX;
D O I
10.1007/s00423-023-03024-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
PurposeWe aimed at exploring indocyanine green (ICG) fluorescence wide spectrum of applications in hepatobiliary surgery as can result particularly useful in robotic liver resections (RLR) in order to overcome some technical limitations, increasing safety, and efficacy.MethodsWe describe our experience of 76 RLR performed between March 2020 and December 2022 exploring all the possible applications of pre- and intraoperative ICG administration.ResultsHepatocellular carcinoma and colorectal liver metastases were the most common indications for RLR (34.2% and 26.7% of patients, respectively), and 51.3% of cases were complex resections with high IWATE difficulty scores. ICG was administered preoperatively in 61 patients (80.3%), intraoperatively in 42 patients (55.3%) and in both contexts in 25 patients (32.9%), with no observed adverse events. The most frequent ICG goal was to achieve tumor enhancement (59 patients, 77.6%), with a success rate of 94.9% and the detection of 3 additional malignant lesions. ICG facilitated evaluation of the resection margin for residual tumor and perfusion adequacy in 33.9% and 32.9% of cases, respectively, mandating a resection enlargement in 7.9% of patients. ICG fluorescence allowed the identification of the transection plane through negative staining in the 25% of cases. Vascular and biliary structures were visualized in 21.1% and 9.2% of patients, with a success rate of 81.3% and 85.7%, respectively.ConclusionRLR can benefit from the routine integration of ICG fluoresce evaluation according to each individual patient and condition-specific goals and issues, allowing liver functional assessment, anatomical and vascular evaluation, tumor detection, and resection margins assessment.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] A retrospective pilot study to examine the feasibility of real-time navigation for laparoscopic liver resections in intrahepatic cholangiocarcinoma using fusion indocyanine green fluorescence imaging
    Zhai, Shu-Ting
    Liang, Xiao
    Mao, Qi-Jiang
    Liang, Yue-Long
    Xu, Jun-Jie
    Chen, Jiang
    Shi, Liang
    Xie, Yang-Yang
    Cai, Xiu-Jun
    JOURNAL OF SURGICAL ONCOLOGY, 2020, 122 (02) : 226 - 233
  • [32] Laparoscopic real-time vessel navigation using indocyanine green fluorescence during laparoscopy-assisted gastric tube reconstruction: First experience
    Ebihara, Yuma
    Shichinohe, Toshiaki
    Kurashima, Yo
    Murakami, Soichi
    Hirano, Satoshi
    JOURNAL OF MINIMAL ACCESS SURGERY, 2021, 17 (04) : 576 - 579
  • [33] Laparoscopic Liver Surgery Guided by Virtual Real-time CT-Guided Volume Navigation
    Aoki, Takeshi
    Mansour, Doaa A.
    Koizumi, Tomotake
    Wada, Yusuke
    Enami, Yuta
    Fujimori, Akira
    Kusano, Tomokazu
    Matsuda, Kazuhiro
    Nogaki, Koji
    Tashiro, Yoshihiko
    Hakozaki, Tomoki
    Shibata, Hideki
    Tomioka, Kodai
    Hirai, Takahito
    Yamazaki, Tatsuya
    Saito, Kazuhiko
    Goto, Satoru
    Watanabe, Makoto
    Otsuka, Koji
    Murakami, Masahiko
    JOURNAL OF GASTROINTESTINAL SURGERY, 2021, 25 (07) : 1779 - 1786
  • [34] Application of Intraoperative Fluorescence Imaging with Indocyanine Green in the Difficult Gallbladder: A Comparative Study between Indocyanine Green-Guided Fluorescence Cholangiography and Conventional Surgery
    Huang, Hai
    Du, Danwei
    Wang, Ziqiang
    Xie, Yangyang
    Ni, Zhongkai
    Li, Xiaowen
    Jin, Haimin
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2023, 33 (04): : 404 - 410
  • [35] Evaluation of Indocyanine Green Fluorescence Imaging for Intraoperative Identification of Liver Malignancy
    Rodriguez, Jorge G. Zarate
    Grendar, Jan
    Wolf, Ronald F.
    Jutric, Zeljka
    Hansen, Paul D.
    Cassera, Maria A.
    Hammill, Chet W.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 39
  • [36] Intraoperative Real-Time Assessment of Liver Function with Near-Infrared Fluorescence Imaging
    Narasaki, Hajime
    Noji, Takehiro
    Wada, Hideyuki
    Ebihara, Yuma
    Tsuchikawa, Takahiro
    Okamura, Keisuke
    Tanaka, Eiichi
    Shichinohe, Toshiaki
    Hirano, Satoshi
    EUROPEAN SURGICAL RESEARCH, 2017, 58 (5-6) : 235 - 245
  • [37] Robotic-assisted stereotactic real-time navigation: initial clinical experience and feasibility for rectal cancer surgery
    Atallah, S.
    Parra-Davila, E.
    Melani, A. G. F.
    Romagnolo, L. G.
    Larach, S. W.
    Marescaux, J.
    TECHNIQUES IN COLOPROCTOLOGY, 2019, 23 (01) : 53 - 63
  • [38] Sentinel lymph node detection in skin cancer patients using real-time fluorescence navigation with indocyanine green: preliminary experience
    Fujiwara, Masao
    Mizukami, Takahide
    Suzuki, Ayano
    Fukamizu, Hidekazu
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2009, 62 (10) : E373 - E378
  • [39] Contrast-Enhanced Intraoperative Ultrasonic Cholangiography for Real-Time Biliary Navigation in Hepatobiliary Surgery
    Urade, Takeshi
    Fukumoto, Takumi
    Tanaka, Motofumi
    Kido, Masahiro
    Takebe, Atsushi
    Kuramitsu, Kaori
    Chuma, Masashi
    Matsumoto, Ippei
    Ajiki, Tetsuo
    Ku, Yonson
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 218 (02) : E43 - E50
  • [40] Real-Time Identification of Liver Cancers by Using Indocyanine Green Fluorescent Imaging
    Ishizawa, Takeaki
    Fukushima, Noriyoshi
    Shibahara, Junji
    Masuda, Koichi
    Tamura, Surnihito
    Aoki, Taku
    Hasegawa, Kiyoshi
    Beck, Yoshifumi
    Fukayama, Masashi
    Kokudo, Norihiro
    CANCER, 2009, 115 (11) : 2491 - 2504