Preoperative planning and intraoperative real-time navigation with indocyanine green fluorescence in robotic liver surgery

被引:3
作者
Rompianesi, Gianluca [1 ]
Pegoraro, Francesca [1 ]
Ramaci, Lorenzo [1 ]
Ceresa, Carlo D. L. [2 ]
Montalti, Roberto [3 ]
Troisi, Roberto, I [1 ]
机构
[1] Federico II Univ Hosp, Dept Clin Med & Surg, Div Hepatobiliary Pancreat Minimally Invas & Robot, Via S Pansini 5, Naples, Italy
[2] Univ Oxford, Nuffield Dept Surg Sci, Oxford, England
[3] Federico II Univ Hosp, Div Hepatobiliary Pancreat Minimally Invas & Robot, Dept Publ Hlth, Naples, Italy
关键词
Hepatobiliary surgery; Robotic surgery; Robotic liver resection; Indocyanine green; Intraoperative fluorescence; Preoperative planning; LAPAROSCOPIC CHOLECYSTECTOMY; HEPATECTOMY; RESECTION; CHOLANGIOGRAPHY; ULTRASOUND; RECONSTRUCTION; COMPLICATIONS; EXPERIENCE; OUTCOMES; INDEX;
D O I
10.1007/s00423-023-03024-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
PurposeWe aimed at exploring indocyanine green (ICG) fluorescence wide spectrum of applications in hepatobiliary surgery as can result particularly useful in robotic liver resections (RLR) in order to overcome some technical limitations, increasing safety, and efficacy.MethodsWe describe our experience of 76 RLR performed between March 2020 and December 2022 exploring all the possible applications of pre- and intraoperative ICG administration.ResultsHepatocellular carcinoma and colorectal liver metastases were the most common indications for RLR (34.2% and 26.7% of patients, respectively), and 51.3% of cases were complex resections with high IWATE difficulty scores. ICG was administered preoperatively in 61 patients (80.3%), intraoperatively in 42 patients (55.3%) and in both contexts in 25 patients (32.9%), with no observed adverse events. The most frequent ICG goal was to achieve tumor enhancement (59 patients, 77.6%), with a success rate of 94.9% and the detection of 3 additional malignant lesions. ICG facilitated evaluation of the resection margin for residual tumor and perfusion adequacy in 33.9% and 32.9% of cases, respectively, mandating a resection enlargement in 7.9% of patients. ICG fluorescence allowed the identification of the transection plane through negative staining in the 25% of cases. Vascular and biliary structures were visualized in 21.1% and 9.2% of patients, with a success rate of 81.3% and 85.7%, respectively.ConclusionRLR can benefit from the routine integration of ICG fluoresce evaluation according to each individual patient and condition-specific goals and issues, allowing liver functional assessment, anatomical and vascular evaluation, tumor detection, and resection margins assessment.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Preoperative planning and intraoperative real-time navigation with indocyanine green fluorescence in robotic liver surgery
    Gianluca Rompianesi
    Francesca Pegoraro
    Lorenzo Ramaci
    Carlo DL Ceresa
    Roberto Montalti
    Roberto I Troisi
    Langenbeck's Archives of Surgery, 408
  • [2] Real-time Navigation for Liver Surgery Using Projection Mapping With Indocyanine Green Fluorescence Development of the Novel Medical Imaging Projection System
    Nishino, Hiroto
    Hatano, Etsuro
    Seo, Satoru
    Nitta, Takashi
    Saito, Tomoyuki
    Nakamura, Masaaki
    Hattori, Kayo
    Takatani, Muneo
    Fuji, Hiroaki
    Taura, Kojiro
    Uemoto, Shinji
    ANNALS OF SURGERY, 2018, 267 (06) : 1134 - 1140
  • [3] Real-time navigation for laparoscopic hepatectomy using image fusion of preoperative 3D surgical plan and intraoperative indocyanine green fluorescence imaging
    Zhang, Peng
    Luo, Huoling
    Zhu, Wen
    Yang, Jian
    Zeng, Ning
    Fan, Yingfang
    Wen, Sai
    Xiang, Nan
    Jia, Fucang
    Fang, Chihua
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2020, 34 (08): : 3449 - 3459
  • [4] Green indocyanine fluorescence in robotic abdominal surgery
    Spinoglio, Giuseppe
    Bertani, Emilio
    Borin, Simona
    Piccioli, Alessandra
    Petz, Wanda
    UPDATES IN SURGERY, 2018, 70 (03) : 375 - 379
  • [5] Liver tumor boundaries identified intraoperatively using real-time indocyanine green fluorescence imaging
    Zhang, Ya-Min
    Shi, Rui
    Hou, Jian-Cun
    Liu, Zi-Rong
    Cui, Zi-Lin
    Li, Yang
    Wu, Di
    Shi, Yuan
    Shen, Zhong-Yang
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2017, 143 (01) : 51 - 58
  • [6] Real-time Vessel Navigation Using Indocyanine Green Fluorescence during Robotic or Laparoscopic Gastrectomy for Gastric Cancer
    Kim, Mina
    Son, Sang-Yong
    Cui, Long-Hai
    Shin, Ho-Jung
    Hur, Hoon
    Han, Sang-Uk
    JOURNAL OF GASTRIC CANCER, 2017, 17 (02) : 145 - 153
  • [7] Real-Time Fluorescence Vessel Navigation Using Indocyanine Green During Laparoscopic Colorectal Cancer Surgery
    Ryu, Shunjin
    Suwa, Katsuhito
    Kitagawa, Takahiro
    Aizawa, Marie
    Ushigome, Takurou
    Okamoto, Tomoyoshi
    Eto, Ken
    Yanaga, Katsuhiko
    ANTICANCER RESEARCH, 2019, 39 (06) : 3009 - 3013
  • [8] Real-time navigation for laparoscopic hepatectomy using image fusion of preoperative 3D surgical plan and intraoperative indocyanine green fluorescence imaging
    Peng Zhang
    Huoling Luo
    Wen Zhu
    Jian Yang
    Ning Zeng
    Yingfang Fan
    Sai Wen
    Nan Xiang
    Fucang Jia
    Chihua Fang
    Surgical Endoscopy, 2020, 34 : 3449 - 3459
  • [9] Added value of indocyanine green fluorescence imaging in liver surgery
    Takemura, Nobuyuki
    Ito, Kyoji
    Inagaki, Fuyuki
    Mihara, Fuminori
    Kokudo, Norihiro
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2022, 21 (04) : 310 - 317
  • [10] Green indocyanine fluorescence in robotic abdominal surgery
    Giuseppe Spinoglio
    Emilio Bertani
    Simona Borin
    Alessandra Piccioli
    Wanda Petz
    Updates in Surgery, 2018, 70 : 375 - 379