Impacts of convection on the thermal performance of radiant heating system with novel dry radiant module

被引:6
作者
Tang, Chunli [1 ]
Liang, Tianchi [1 ]
Nong, Guimin [1 ]
机构
[1] Jiangsu Univ Sci & Technol, Sch Energy & Power, Zhenjiang 212100, Peoples R China
关键词
Radiant floor heating system; Dry radiant module; Combined convection-radiation system; Transient response; Temperature distribution; FLOOR; SIMULATION; MODEL;
D O I
10.1016/j.buildenv.2023.110370
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The transient response of the radiant floor heating system (RFHS) and the influence of convection on the radiant heating are rarely reported. In this work, Experiments were carried out for independent RFHS (case A) and combined RFHS with convection (case B). The dry radiant module (DRM) was applied to the radiant floor, and the assisted ventilation was used selectively to investigate its influence on the thermal performance. Compared with the independent RFHS, the convection is effective to reduce the startup time by 20 min, and to accelerate the decrease in air temperature after shutdown. The floor surface temperature has a dropping-rising-dropping trend when the system is shutdown no matter the fan coil works or not. But the rising range of case B is smaller than case A. It shows that the combined system can reduce the influence of the thermal inertia of the radiant floor, improve the reaction of indoor air, and meet the requirement of rapid heating better. For case B, the horizontal temperature fluctuation is smaller at 0.1 m height and larger at 1.7 m height than case A. The simulation results indicate that the forced airstream breaks the air circulation caused by natural convection, and causes a significant vertical temperature fluctuation. The results provide a guide for better design and operation of RFHS.
引用
收藏
页数:11
相关论文
共 32 条
  • [1] [Anonymous], 2017, 55 ANSI ASHRAE
  • [2] ASHRAE, 2021, ASHRAE HDB FUND SI
  • [3] Model predictive control optimization for rapid response and energy efficiency based on the state-space model of a radiant floor heating system
    Chen, Qiong
    Li, Nan
    Feng, Wei
    [J]. ENERGY AND BUILDINGS, 2021, 238
  • [4] Experimental and numerical study on the application of low-temperature radiant floor heating system with capillary tube: Thermal performance analysis
    Cho, Jinkyun
    Park, Beungyong
    Lim, Taesub
    [J]. APPLIED THERMAL ENGINEERING, 2019, 163
  • [5] Study on heating capacity and heat loss of capillary radiant floor heating systems
    Ding, Pei
    Li, Yanru
    Long, Enshen
    Zhang, Yin
    Liu, Qinjian
    [J]. APPLIED THERMAL ENGINEERING, 2020, 165
  • [6] Experimental investigation of energy-optimum radiant-convective heat transfer split for hybrid heating systems
    Evren, Mustafa Fatih
    Ozsunar, Abuzer
    Kilkis, Birol
    [J]. ENERGY AND BUILDINGS, 2016, 127 : 66 - 74
  • [7] Shape optimisation for the improved performance of a novel bi-directional flow rate measuring device: Olive-shaped flowmeter (OSF)
    Feng, Guozeng
    Gu, Xinxin
    Shi, Dachuan
    Guo, Yuejiao
    [J]. MEASUREMENT, 2022, 188
  • [8] Transient simulation of a storage floor with a heating/cooling parallel pipe system
    Flores Larsen, Silvana
    Filippin, Celina
    Lesino, Graciela
    [J]. BUILDING SIMULATION, 2010, 3 (02) : 105 - 115
  • [9] Holman J.P., 2016, Heat Transfer, P11
  • [10] Uneven gridding of thermal nodal networks in floor heating simulations
    Holopainen, R.
    Tuomaala, P.
    Piippo, J.
    [J]. ENERGY AND BUILDINGS, 2007, 39 (10) : 1107 - 1114