Implant survival/success and peri-implant outcomes of titanium-zirconium mini implants for mandibular overdentures: Results from a 1-year randomized clinical trial

被引:11
作者
Curado, Thalita Fernandes Fleury [1 ]
Silva, Jesio Rodrigues [1 ]
Nascimento, Lays Noleto [1 ]
Leles, Jose Luiz Rodrigues [2 ]
McKenna, Gerald [3 ]
Schimmel, Martin [4 ,5 ]
Leles, Claudio Rodrigues [1 ,4 ,6 ]
机构
[1] Univ Fed Goias, Sch Dent, Goiania, Brazil
[2] Univ Paulista, Goiania, Brazil
[3] Queens Univ Belfast, Ctr Publ Hlth, Belfast, North Ireland
[4] Sch Dent Med Univ Bern, Dept Reconstruct Dent, Div Gerodontol, Bern, Switzerland
[5] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[6] Univ Fed Goias, Fac Odontol, Praca Univ,s-n,Setor Univ, BR-74605220 Goiania, GO, Brazil
关键词
clinical assessment; clinical research; clinical trials; dental implant; diagnosis; edentulous patient; SUCCESS; DESIGN; TI;
D O I
10.1111/clr.14102
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To report the 1-year implant survival/success and peri-implant outcomes of mandibular overdentures retained by four titanium-zirconium mini implants (Straumann (R) Mini Implant System), and to assess how surgery and loading protocols influence these outcomes. Materials and Methods: A 2 x 2 factorial randomized clinical trial (RCT) tested the combined effects of two loading protocols (immediate or delayed) and two surgical approaches (flapless or flapped) on the success/survival of the mini implants, and peri-implant parameters (plaque, bleeding, sulcus depth, gingival position, and marginal bone loss). Outcomes were assessed up to 1-year after loading, and generalized estimating equations (GEEs) were used to analyze longitudinal and within-patient clustered data. Results: Two hundred and ninety-six implants were placed in 74 patients. The implant survival/success rates after 1 year were 100%, and no major biological complications were observed. After 1-year, descriptive data suggest no noticeable changes in plaque scores, whilst a reduction in bleeding scores at the 6-month and 1-year follow-ups compared to baseline. Good longitudinal stability was observed for the probing depth and gingival margin height measures. Overall mean marginal bone loss was 0.68 (+/- 0.68) mm after 3 months and 0.89 (+/- 0.75) mm after 1-year. The flapless protocol showed better results on soft tissue stability and health but a slightly higher risk for marginal bone loss. Conclusion: The results of this RCT suggest that mandibular overdentures retained by this novel mini implant system represent a safe and predictable treatment option as confirmed by implant survival/success and peri-implant outcomes, even when flapless surgery and immediate loading protocols are adopted.
引用
收藏
页码:769 / 782
页数:14
相关论文
共 50 条
  • [21] Inflammatory effects of individualized abutments bonded onto titanium base on peri-implant tissue health: A randomized controlled clinical trial
    Rathe, Florian
    Junker, Rudiger
    Groger, Sabine
    Meyle, Jorg
    Schlee, Markus
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (06) : 874 - 882
  • [22] Comparative clinical study of conventional dental implant and mini dental implant-retained mandibular overdenture: A 5-to 8-Year prospective clinical outcomes in a previous randomized clinical trial
    Chatrattanarak, Wipawan
    Aunmeungtong, Weerapan
    Khongkhunthian, Pathawee
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (04) : 475 - 487
  • [23] Long-term effects of titanium-base abutments on peri-implant health: A 5-year randomized controlled trial
    Rathe, Florian
    Junker, Ruediger
    Heumann, Christian
    Blumenroehr, Julia
    Auschill, Thorsten
    Arweilei, Nicole
    Schlee, Markus
    IMPLANTOLOGIE, 2022, 30 (04): : 403 - 416
  • [24] Quantitative evaluation of connective tissue grafts on peri-implant tissue morphology in the esthetic zone: A 1-year prospective clinical study
    Kobayashi, Tomoyuki
    Nakano, Tamaki
    Ono, Shinji
    Matsumura, Atsushi
    Yamada, Shuhei
    Yatani, Hirofumi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 311 - 318
  • [25] Connective tissue grafts for thickening peri-implant tissues at implant placement. One-year results from an explanatory split-mouth randomised controlled clinical trial
    Wiesner, Guenter
    Esposito, Marco
    Worthington, Helen
    Schlee, Markus
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2010, 3 (01) : 27 - 35
  • [26] Comparison of peri-implant crevicular fluid levels of adrenomedullin and human beta defensins 1 and 2 from mandibular implants with different implant stability quotient levels in nonsmoker patients
    Ertugrul, A. S.
    Tekin, Y.
    Alpaslan, N. Z.
    Bozoglan, A.
    Sahin, H.
    Dikilitas, A.
    JOURNAL OF PERIODONTAL RESEARCH, 2014, 49 (04) : 480 - 488
  • [27] Do postoperative antibiotics influence one-year peri-implant crestal bone remodelling and morbidity? A double-blinded randomized clinical trial
    Durand, Robert
    Kersheh, Issam
    Marcotte, Stephanie
    Boudrias, Pierre
    Schmittbuhl, Matthieu
    Cresson, Thierry
    Rei, Nathalie
    Rompre, Pierre H.
    Voyer, Rene
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (11) : 1318 - 1327
  • [28] Soft-tissue dimensional change following guided bone regeneration on peri-implant defects using soft-type block or particulate bone substitutes: 1-year outcomes of a randomized controlled clinical trial
    Song, Young Woo
    Bienz, Stefan P.
    Benic, Goran, I
    Cha, Jae-Kook
    Haemmerle, Christoph H. F.
    Jung, Ui-Won
    Jung, Ronald E.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2023, 50 (02) : 147 - 157
  • [29] Clinical Outcomes of Three versus Four Mini-Implants Retaining Mandibular Overdenture: A 5-Year Randomized Clinical Trial
    Celebic, Asja
    Kovacic, Ines
    Petricevic, Nikola
    Alhajj, Mohammed Nasser
    Topic, Jolanda
    Junakovic, Luka
    Persic-Kirsic, Sanja
    MEDICINA-LITHUANIA, 2024, 60 (01):
  • [30] Early Loading of Mandibular Molar Single Implants: 1 Year Results of a Randomized Controlled Clinical Trial
    Lee, Jungwon
    Lim, Young-Jun
    Kim, Bongju
    Koo, Ki-Tae
    MATERIALS, 2020, 13 (18)