Automatic detection of posterior superior alveolar artery in dental cone-beam CT images using a deeply supervised multi-scale 3D network

被引:2
作者
Park, Jae-An [1 ,2 ]
Kim, Dael [3 ]
Yang, Su [4 ]
Kang, Ju-Hee [5 ]
Kim, Jo-Eun [1 ,2 ]
Huh, Kyung-Hoe [1 ,2 ]
Lee, Sam-Sun [1 ,2 ]
Yi, Won-Jin [1 ,2 ]
Heo, Min-Suk [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dent Res Inst, Sch Dent, 101 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Grad Sch, Interdisciplinary Program Bioengn, 1 Gwanak Ro, Seoul 08826, South Korea
[4] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Appl Bioengn, 1 Gwanak Ro, Seoul 08826, South Korea
[5] Seoul Natl Univ, Dent Hosp, Dept Oral & Maxillofacial Radiol, 101 Daehak Ro, Seoul 03080, South Korea
基金
新加坡国家研究基金会;
关键词
arteries; cone-beam computed tomography; deep learning; maxillary sinus; MAXILLARY SINUS; COMPUTED-TOMOGRAPHY; SEGMENTATION; PERFORMANCE;
D O I
10.1093/dmfr/twad002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study aimed to develop a robust and accurate deep learning network for detecting the posterior superior alveolar artery (PSAA) in dental cone-beam CT (CBCT) images, focusing on the precise localization of the centre pixel as a critical centreline pixel.Methods PSAA locations were manually labelled on dental CBCT data from 150 subjects. The left maxillary sinus images were horizontally flipped. In total, 300 datasets were created. Six different deep learning networks were trained, including 3D U-Net, deeply supervised 3D U-Net (3D U-Net DS), multi-scale deeply supervised 3D U-Net (3D U-Net MSDS), 3D Attention U-Net, 3D V-Net, and 3D Dense U-Net. The performance evaluation involved predicting the centre pixel of the PSAA. This was assessed using mean absolute error (MAE), mean radial error (MRE), and successful detection rate (SDR).Results The 3D U-Net MSDS achieved the best prediction performance among the tested networks, with an MAE measurement of 0.696 +/- 1.552 mm and MRE of 1.101 +/- 2.270 mm. In comparison, the 3D U-Net showed the lowest performance. The 3D U-Net MSDS demonstrated a SDR of 95% within a 2 mm MAE. This was a significantly higher result than other networks that achieved a detection rate of over 80%.Conclusions This study presents a robust deep learning network for accurate PSAA detection in dental CBCT images, emphasizing precise centre pixel localization. The method achieves high accuracy in locating small vessels, such as the PSAA, and has the potential to enhance detection accuracy and efficiency, thus impacting oral and maxillofacial surgery planning and decision-making.
引用
收藏
页码:22 / 31
页数:10
相关论文
共 49 条
[1]   Does intraoperative perforation of Schneiderian membrane during sinus lift surgery causes an increased the risk of implants failure?: A systematic review and meta regression analysis [J].
Al-Moraissi, Essam ;
Elsharkawy, Ahmed ;
Abotaleb, Bassam ;
Alkebsi, Khaled ;
Al-Motwakel, Hamza .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) :882-889
[2]   Dilated Volumetric Network: an Enhanced Fully Convolutional Network for Volumetric Prostate Segmentation from Magnetic Resonance Imaging [J].
Aman Agarwal ;
Mishra, Aditya ;
Basavarajaiah, Madhushree ;
Sharma, Priyanka ;
Tanwar, Sudeep .
PATTERN RECOGNITION AND IMAGE ANALYSIS, 2021, 31 (02) :228-239
[3]   Meningioma Segmentation in T1-Weighted MRI Leveraging Global Context and Attention Mechanisms [J].
Bouget, David ;
Pedersen, Andre ;
Hosainey, Sayied Abdol Mohieb ;
Solheim, Ole ;
Reinertsen, Ingerid .
FRONTIERS IN RADIOLOGY, 2021, 1
[4]   Deep learning-based fully automatic segmentation of the maxillary sinus on cone-beam computed tomographic images [J].
Choi, Hanseung ;
Jeon, Kug Jin ;
Kim, Young Hyun ;
Ha, Eun-Gyu ;
Lee, Chena ;
Han, Sang-Sun .
SCIENTIFIC REPORTS, 2022, 12 (01)
[5]  
Cicek Ozgun, 2016, Medical Image Computing and Computer-Assisted Intervention - MICCAI 2016. 19th International Conference. Proceedings: LNCS 9901, P424, DOI 10.1007/978-3-319-46723-8_49
[6]   A fully automatic AI system for tooth and alveolar bone segmentation from cone-beam CT images [J].
Cui, Zhiming ;
Fang, Yu ;
Mei, Lanzhuju ;
Zhang, Bojun ;
Yu, Bo ;
Liu, Jiameng ;
Jiang, Caiwen ;
Sun, Yuhang ;
Ma, Lei ;
Huang, Jiawei ;
Liu, Yang ;
Zhao, Yue ;
Lian, Chunfeng ;
Ding, Zhongxiang ;
Zhu, Min ;
Shen, Dinggang .
NATURE COMMUNICATIONS, 2022, 13 (01)
[7]   Evaluation of the posterior superior alveolar artery canal by cone-beam computed tomography in a sample of the Egyptian population [J].
Fayek, Marco Malak ;
Amer, Maha Eshak ;
Bakry, Ahmed Mohamed .
IMAGING SCIENCE IN DENTISTRY, 2021, 51 (01) :35-40
[8]  
Flanagan Dennis, 2005, Implant Dent, V14, P336
[9]   Artificial intelligence in oral and maxillofacial radiology: what is currently possible? [J].
Heo, Min-Suk ;
Kim, Jo-Eun ;
Hwang, Jae-Joon ;
Han, Sang-Sun ;
Kim, Jin-Soo ;
Yi, Won-Jin ;
Park, In-Woo .
DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (03)
[10]   Densely Connected Convolutional Networks [J].
Huang, Gao ;
Liu, Zhuang ;
van der Maaten, Laurens ;
Weinberger, Kilian Q. .
30TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2017), 2017, :2261-2269