The Feasibility of Multiple Fixation Points in C2

被引:1
作者
Ngoc, Quyen Nguyen [1 ]
Riew, K. Daniel [2 ,3 ]
Lee, So Min [4 ,5 ]
Park, Sang-Min [4 ,5 ]
Kim, Ho-Joong [4 ,5 ]
Chang, Bong-Soon [6 ]
Lee, Sang-Hun [7 ]
Lee, Jae Chul [8 ]
Yeom, Jin S. [4 ,5 ]
机构
[1] 108 Mil Cent Hosp, Polyclin & Premier Healthcare Ctr, Spine Surg Unit, Hanoi, Vietnam
[2] Columbia Univ, Dept Orthopaed Surg, New York, NY USA
[3] Weill Cornell Med Sch, Dept Neurol Surg, New York, NY USA
[4] Seoul Natl Univ, Bundang Hosp, Coll Med, Spine Ctr, 82 Gumi Ro 173beon Gil, Seongnam 13620, South Korea
[5] Seoul Natl Univ, Bundang Hosp, Coll Med, Dept Orthopaed Surg, 82 Gumi Ro 173beon Gil, Seongnam 13620, South Korea
[6] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
[7] Johns Hopkins Univ, Sch Med, Dept Orthopaed Surg, Baltimore, MD USA
[8] Soonchunhyang Univ, Seoul Hosp, Dept Orthopaed Surg, Seoul, South Korea
关键词
C2; Pedicle screw; Laminar screw; Multiple screw fixation; SCREWS; PEDICLE; SPINE;
D O I
10.31616/asj.2023.0233
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: This was an analysis using three-dimensional simulation software for spinal screw placement and computed tomographic scan images. Purpose: To assess the feasibility of achieving multiple (three or four) screw fixation points in C2 vertebra by using a combination of pedicle and laminar screws. Overview of Literature: Secure C2 fixation using multiple screws is required or beneficial in some unique cases. However, to the best of our knowledge, no reports have analyzed the feasibility of multiple screw fixation in C2. Methods: We used computed tomographic scan images with an interval of 1.0 mm obtained from 100 patients (50 men and 50 women) and screw trajectory simulation software. The diameter of all screws was set at 3.5 mm, considering its common usage in real surgery. The anatomical feasibility of placing both pedicle and laminar screws on the same side was evaluated. For all feasible sides, the three-dimensional distance between the screw entry points was measured. Results: In 85% of the cases under study, both pedicle and laminar screws could be placed on both sides, allowing the insertion of four screws. In 11% of the cases under study, two screws could be placed on one side, whereas only one screw was feasible on the other side, resulting in the placement of three screws. In all 181 sides where both screw types could be inserted, the distance between their entry points exceeded 16.1 mm, which was sufficient to prevent collision between the screw heads. Conclusions: The C2 vertebra can accommodate three (11%) or four (85%) screws in 96% of the cases under study.
引用
收藏
页码:888 / 893
页数:6
相关论文
共 10 条
  • [1] AlfonsoPadua MR, 2013, Spine (Phila Pa 1976, V38, P1146
  • [2] Axis screws: results and complications of a large case series
    Formentin, Cleiton
    Junior de Andrade, Erion
    Maeda, Fernando Luis
    Ghizoni, Enrico
    Tedeschi, Helder
    Joaquim, Andrei F.
    [J]. REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2019, 65 (02): : 198 - 203
  • [3] 4-Point C2 Fixation for Occipitocervical Fusion: Technical Case Report
    Houten, John K.
    Kinon, Merritt D.
    Weinstein, Gila R.
    [J]. WORLD NEUROSURGERY, 2021, 148 : 38 - 43
  • [4] Posterior fusion of the occipital axis in children with upper cervical disorder using both C2 pedicle and laminar screws (C2 hybrid screws)
    Ito, Kenyu
    Imagama, Shiro
    Ando, Kei
    Kobayashi, Kazuyoshi
    Tsushima, Mikito
    Matsumoto, Akiyuki
    Morozumi, Masayoshi
    Tanaka, Satoshi
    Machino, Masaaki
    Nishida, Yoshihiro
    Ishiguro, Naoki
    [J]. SPINE SURGERY AND RELATED RESEARCH, 2018, 2 (01):
  • [5] Bilateral Pedicle and Crossed Translaminar Screws in C2
    Mendelsohn, Daniel
    Dea, Nicolas
    Lee, Robert
    Boyd, Michael C.
    [J]. ASIAN SPINE JOURNAL, 2015, 9 (05) : 783 - 788
  • [6] The feasibility of laminar screw placement in the subaxial spine: analysis using 215 three-dimensional computed tomography scans and simulation software
    Shin, Sang Ik
    Yeom, Jin S.
    Kim, Ho-Joong
    Chang, Bong-Soon
    Lee, Choon-Ki
    Riew, K. Daniel
    [J]. SPINE JOURNAL, 2012, 12 (07) : 577 - 584
  • [7] New Techniques for Exposure of Posterior Cervical Spine Through Intermuscular Planes and Their Surgical Application
    Shiraishi, Tateru
    Kato, Masahiro
    Yato, Yoshiyuki
    Ueda, Seiji
    Aoyama, Ryoma
    Yamane, Jun-ichi
    Kitamura, Kazuya
    [J]. SPINE, 2012, 37 (05) : E286 - E296
  • [8] Simultaneous Use of Both Bilateral Intralaminar and Pedicle Screws for C2 Stabilization
    Tarukado, Kiyoshi
    Tono, Osamu
    Doi, Toshio
    [J]. ASIAN SPINE JOURNAL, 2015, 9 (05) : 789 - 793
  • [9] Posterior C2 fixation using bilateral, crossing C2 laminar screws - Case series and technical note
    Wright, NM
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (02): : 158 - 162
  • [10] Undetected Vertebral Artery Groove and Foramen Violations During C1 Lateral Mass and C2 Pedicle Screw Placement
    Yeom, Jin S.
    Buchowski, Jacob M.
    Park, Kun-Woo
    Chang, Bong-Soon
    Lee, Choon-Ki
    Riew, K. Daniel
    [J]. SPINE, 2008, 33 (25) : E942 - E949