Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression-An In Vitro Study

被引:1
|
作者
Becker, Alexander [1 ]
Dirksen, Dieter [1 ]
Runte, Christoph [1 ]
机构
[1] Univ Munster, Dept Prosthet Dent & Biomat, D-48149 Munster, Germany
关键词
implant impression; implant position transfer; prosthetic restoration on implants; DIMENSIONAL ACCURACY;
D O I
10.3390/dj11090208
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The accuracy for the implant position transfer of a mounting fixture and a standardized open-tray implant level impression was compared. Ten aluminum master models with four implant analogs placed in different angulations were fabricated. By performing an open-tray implant level impression stone casts were produced. The master models and stone casts were scanned (comparison group one) using a laboratory scanner. Deviations in the scan body surface were determined in the form of mean (absolute) point distances and (signed) surface distances. The same procedure was performed with a screwed transfer and by fixing the posts of the mounting fixture (comparison group two). The mounting device was applied to each master model and scanned in a fixed and detached state (comparison group three). In a point comparison, the open-tray implant level impression showed mean deviations of 43.6 mu m and a mounting fixture of 44.6 mu m with no significant differences (p < 0.05). There were significant differences between groups two and three. The angulation of the implants had no effect on the accuracy. In a surface comparison, the open-tray implant level impression showed mean deviations of 36.0 mu m and a mounting fixture of 2.0 mu m (p > 0.05). Within the limits of this study, the mounting fixture transferred the implant position with the same accuracy as the open-tray implant level impression with respect to point deviations.
引用
收藏
页数:13
相关论文
共 31 条
  • [21] The influence of the superimposition procedure and type of intraoral impression on the superimposition accuracy of CBCT scans with dental impressions in implant planning: an in-vitro study
    Motel, Constantin
    Kirschner, Carolin
    Foertsch, Felix
    Buchbender, Mayte
    Wichmann, Manfred
    Matta, Ragai-Edward
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)
  • [22] Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study
    Zhou, Miao
    Zhou, Hui
    Li, Shu-Yi
    Zhu, Yi-Bo
    Geng, Yuan-Ming
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : 343 - 348
  • [23] Comparison of accuracy of hexed and nonhexed pickup impression copings in a multiple variable impression setup for recording multiple straight and angulated implant positions: An in vitro study
    Kaur, Tavleen
    Singla, Shefali
    Kumar, Lalit
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2023, 23 (01) : 21 - 29
  • [24] Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray
    Goel, Mukti
    Dhawan, Pankaj
    Tandan, Piyush
    Madhukar, Pankaj
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (03): : 271 - 276
  • [25] Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study
    Hama, Dler Raouf
    Mahmood, Bayad Jaza
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2023, 53 (05): : 388 - 401
  • [26] Comparison of the accuracy of dental implant placement using dynamic and augmented reality-based dynamic navigation: An in vitro study
    Tao, Baoxin
    Fan, Xingqi
    Wang, Feng
    Chen, Xiaojun
    Shen, Yihan
    Wu, Yiqun
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 196 - 202
  • [27] Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete-Arch Implant Impression: An In Vitro Study
    Fu, Xiao-Jiao
    Liu, Min
    Shi, Jun-Yu
    Deng, Ke
    Lai, Hong-Chang
    Gu, Wen
    Zhang, Xiao-Meng
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (01) : 17 - 27
  • [28] Effect of the level of alveolar atrophy on implant placement accuracy in guided surgery for full-arch restorations supported by four implants: an in vitro study
    Gökhan Göçmen
    Ahmet Bayrakçıoğlu
    Ferit Bayram
    Head & Face Medicine, 19
  • [29] Effect of the level of alveolar atrophy on implant placement accuracy in guided surgery for full-arch restorations supported by four implants: an in vitro study
    Gocmen, Gokhan
    Bayrakcioglu, Ahmet
    Bayram, Ferit
    HEAD & FACE MEDICINE, 2023, 19 (01)
  • [30] Evaluation and Comparison of Accuracy of Complete Arch Digital and Conventional Implant Impression as Influenced by the Use of a 3D Printed Modular Splint -An In-Vitro Study
    Pol, Bhushan S.
    Sabane, Ajay V.
    Jadhav, Rajashree D.
    Kadam, Pankaj P.
    Gachake, Arti R.
    Kalsekar, Bhagyashree G.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 (SUPPL 4) : S3764 - S3767