The role of the electroencephalogram (EEG) in determining the aetiology of catatonia: a systematic review and meta-analysis of diagnostic test accuracy

被引:6
作者
Hosseini, Paris [1 ]
Whincup, Rebecca [2 ]
Devan, Karrish [3 ]
Ghanem, Dory Anthony [4 ]
Fanshawe, Jack B. [5 ]
Saini, Aman [4 ]
Cross, Benjamin [6 ]
Vijay, Apoorva [7 ]
Mastellari, Tomas [8 ,9 ]
Vivekananda, Umesh [10 ,11 ]
White, Steven [12 ]
Brunnhuber, Franz [13 ]
Zandi, Michael S. [11 ,14 ]
David, Anthony S. [15 ]
Carter, Ben [16 ]
Oliver, Dominic [17 ]
Lewis, Glyn [9 ]
Fry, Charles [14 ]
Mehta, Puja R. [14 ]
Stanton, Biba [18 ,19 ]
Rogers, Jonathan P. [3 ,8 ,20 ]
机构
[1] Univ Coll London Hosp NHS Fdn Trust, Dept Neuropsychiat, London, England
[2] Leicestershire Partnership NHS Trust, Leicester, England
[3] South London & Maudsley NHS Fdn Trust, London, England
[4] UCL, Med Sch, London, England
[5] Univ Oxford, Dept Psychiat, Oxford, England
[6] Mersey Care NHS Fdn Trust, Prescot, England
[7] Kings Coll London, GKT Sch Med Educ, London, England
[8] UCL, Div Psychiat, London, England
[9] Univ Lille, CHU Lille, Lille Neurosci & Cognit LilNCog, Inserm U1172, Lille, France
[10] Inst Neurol UCL, Dept Clin & Expt Epilepsy, London, England
[11] Natl Hosp Neurol & Neurosurg, London, England
[12] Natl Hosp Neurol & Neurosurg, Dept Clin Neurophysiol, London, England
[13] Kings Coll Hosp NHS Fdn Trust, Dept Clin Neurophysiol, London, England
[14] UCL, Queen Sq Inst Neurol, London, England
[15] UCL, Inst Mental Hlth, London, England
[16] Kings Coll London, Dept Biostat & Hlth Informat, London, England
[17] Kings Coll London, Dept Psychosis Studies, London, England
[18] Kings Coll Hosp NHS Fdn Trust, Dept Neurol, London, England
[19] St Thomas Hosp, South London & Maudsley NHS Trust, Neuropsychiat Serv, London, England
[20] UCL Div Psychiat, 6th Floor,Maple House,149 Tottenham Court Rd, London W1T 7NF, England
基金
英国惠康基金;
关键词
Catatonia; Electroencephalogram; EEG; Systematic review; Meta-analysis; Diagnostic test accuracy; ENCEPHALITIS; DELIRIUM; QUALITY; ONSET;
D O I
10.1016/j.eclinm.2022.101808
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Catatonia is a psychomotor syndrome that has a wide range of aetiologies. Determining whether cata-tonia is due to a medical or psychiatric cause is important for directing treatment but is clinically challenging. We aimed to ascertain the performance of the electroencephalogram (EEG) in determining whether catatonia has a medical or psychiatric cause, conventionally defined.Methods In this systematic review and meta-analysis of diagnostic test accuracy (PROSPERO CRD42021239027), Medline, EMBASE, PsycInfo, and AMED were searched from inception to May 11, 2022 for articles published in peer-reviewed journals that reported EEG findings in catatonia of a medical or psychiatric origin and were reported in English, French, or Italian. Eligible study types were clinical trials, cohort studies, case-control studies, cross-sectional studies, case series, and case reports. The reference standard was the final clinical diagnosis. Data extraction was conducted using individual patient-level data, where available, by two authors. We prespecified two types of studies to overcome the limitations anticipated in the data: larger studies (n >= 5), which were suitable for formal meta-analytic methods but generally lacked detailed information about participants, and smaller studies (n < 5), which were unsuitable for formal meta-analytic methods but had detailed individual patient level data, enabling additional sensitivity analyses. Risk of bias and applicability were assessed with the QUADAS-2 tool for larger studies, and with a published tool designed for case reports and series for smaller studies. The primary outcomes were sensitivity and specificity, which were derived using a bivariate mixed-effects regression model.Findings 355 studies were included, spanning 707 patients. Of the 12 larger studies (5 cohort studies and 7 case series), 308 patients were included with a mean age of 48.2 (SD = 8.9) years. 85 (52.8%) were reported as male and 99 had catatonia due to a general medical condition. In the larger studies, we found that an abnormal EEG predicted a medical cause of catatonia with a sensitivity of 0.82 (95% CI 0.67-0.91) and a specificity of 0.66 (95% CI 0.45-0.82) with an I2 of 74% (95% CI 42-100%). The area under the summary ROC curve offered excellent discrimination (AUC = 0.83). The positive likelihood ratio was 2.4 (95% CI 1.4-4.1) and the negative likelihood ratio was 0.28 (95% CI 0.15-0.51). Only 5 studies had low concerns in terms of risk of bias and applicability, but a sensitivity analysis limited to these studies was similar to the main analysis. Among the 343 smaller studies, 399 patients were included, resulting in a sensitivity of 0.76 (95% CI 0.71-0.81), specificity of 0.67 (0.57-0.76) and AUC = 0.71 (95% CI 0.67-0.76). In multiple sensitivity analyses, the results were robust to the exclusion of reports of studies and in-dividuals considered at high risk of bias. Features of limbic encephalitis, epileptiform discharges, focal abnormality, or status epilepticus were highly specific to medical catatonia, but features of encephalopathy had only moderate specificity and occurred in 23% of the cases of psychiatric catatonia in smaller studies.Interpretation In cases of diagnostic uncertainty, the EEG should be used alongside other investigations to ascertain whether the underlying cause of catatonia is medical. The main limitation of this review is the differing thresholds for considering an EEG abnormal between studies. Funding Wellcome Trust, NIHR Biomedical Research Centre at University College London Hospitals NHS Foun-dation Trust.Copyright (c) 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Diagnostic test accuracy of adenosine deaminase for tuberculous meningitis: A systematic review and meta-analysis
    Pormohammad, Ali
    Riahi, Seyed-Mohammad
    Nasiri, Mohammad Javad
    Fallah, Fatemeh
    Aghazadeh, Mohammad
    Doustdar, Farahnoosh
    Pouriran, Ramin
    JOURNAL OF INFECTION, 2017, 74 (06) : 545 - 554
  • [22] A systematic review and diagnostic test accuracy meta-analysis of the validity of anion gap as a screening tool for hyperlactatemia
    Glasmacher S.A.
    Stones W.
    BMC Research Notes, 10 (1)
  • [23] A step-by-step guide to the systematic review and meta-analysis of diagnostic and prognostic test accuracy evaluations
    Z Liu
    Z Yao
    C Li
    X Liu
    H Chen
    C Gao
    British Journal of Cancer, 2013, 108 : 2299 - 2303
  • [24] Diagnostic Test Accuracy of Deep Learning Detection of COVID-19: A Systematic Review and Meta-Analysis
    Komolafe, Temitope Emmanuel
    Cao, Yuzhu
    Nguchu, Benedictor Alexander
    Monkam, Patrice
    Olaniyi, Ebenezer Obaloluwa
    Sun, Haotian
    Zheng, Jian
    Yang, Xiaodong
    ACADEMIC RADIOLOGY, 2021, 28 (11) : 1507 - 1523
  • [25] The diagnostic accuracy of direct agglutination test for serodiagnosis of human visceral leishmaniasis: a systematic review with meta-analysis
    Mehdi Mohebali
    Hossein Keshavarz
    Sedigheh Shirmohammad
    Behnaz Akhoundi
    Alireza Borjian
    Gholamreza Hassanpour
    Setareh Mamishi
    Shima Mahmoudi
    BMC Infectious Diseases, 20
  • [26] A step-by-step guide to the systematic review and meta-analysis of diagnostic and prognostic test accuracy evaluations
    Liu, Z.
    Yao, Z.
    Li, C.
    Liu, X.
    Chen, H.
    Gao, C.
    BRITISH JOURNAL OF CANCER, 2013, 108 (11) : 2299 - 2303
  • [27] Digital breast tomosynthesis for breast cancer detection: a diagnostic test accuracy systematic review and meta-analysis
    Mostafa Alabousi
    Nanxi Zha
    Jean-Paul Salameh
    Lucy Samoilov
    Anahita Dehmoobad Sharifabadi
    Alex Pozdnyakov
    Behnam Sadeghirad
    Vivianne Freitas
    Matthew D. F. McInnes
    Abdullah Alabousi
    European Radiology, 2020, 30 : 2058 - 2071
  • [28] The accuracy of haemoglobin A1c as a screening and diagnostic test for gestational diabetes: a systematic review and meta-analysis of test accuracy studies
    Amaefule, Chiamaka Esther
    Sasitharan, Archana
    Kalra, Princee
    Iliodromoti, Stamatina
    Huda, Mohammed S. B.
    Rogozinska, Ewelina
    Zamora, Javier
    Thangaratinam, Shakila
    CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2020, 32 (05) : 322 - 334
  • [29] A Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the Advanced Clinical Solutions Word Choice Test as a Performance Validity Test
    Bernstein, Matthew T.
    Resch, Zachary J.
    Ovsiew, Gabriel P.
    Soble, Jason R.
    NEUROPSYCHOLOGY REVIEW, 2021, 31 (02) : 349 - 359
  • [30] A Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the Advanced Clinical Solutions Word Choice Test as a Performance Validity Test
    Matthew T. Bernstein
    Zachary J. Resch
    Gabriel P. Ovsiew
    Jason R. Soble
    Neuropsychology Review, 2021, 31 : 349 - 359