Dynamic Contrast-enhanced CT Lymphangiography to Quantify Thoracic Duct Lymphatic Flow

被引:1
作者
Molloi, Sabee [1 ]
Polivka, Alesh R. [1 ]
Zhao, Yixiao [1 ]
Redmond, Jonas [3 ]
Itkin, Maxim [4 ]
Antunes, Ines [1 ]
Yu, Zhaoxia [2 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Med Sci 1,B-140, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Stat, Med Sci 1,B-140, Irvine, CA 92697 USA
[3] Univ Calif San Diego, Dept Radiol Sci, San Diego, CA USA
[4] Univ Penn, Dept Radiol, Philadelphia, PA USA
关键词
MR LYMPHANGIOGRAPHY; VENOUS-PRESSURE; GADOFOSVESET; DIAGNOSIS; FAILURE;
D O I
10.1148/radiol.230959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: CT lymphangiography has been used to image the lymphatic anatomy and assess lymphatic abnormalities. There is, however, a need to develop a method for quantification of lymphatic flow rate in the thoracic duct (TD). Purpose: To develop and validate a TD lymphatic flow measurement technique using dynamic contrast -enhanced CT lymphangiography. Materials and Methods: Lymphatic flow rate was measured with two techniques: a first -pass analysis technique based on a single compartment model and a thresholding technique distinguishing between opacified and nonopacified voxels within the TD. The measurements were validated in a swine animal model between November 2021 and September 2022. CT images were acquired at 100 kV and 200 mA using a fast -pitched helical scan mode covering the entire TD following contrast material injection into the bilateral inguinal lymph nodes. Two helical CT scans, acquired at the base and peak contrast enhancement of the TD, were used to measure lymphatic flow rate. A US flow probe surgically placed around the TD provided the reference standard measurement. CT lymphatic flow measurements were compared with the reference US flow probe measurements using regression and Bland -Altman analysis. Repeatability was determined using repeated flow measurements within approximately 10 minutes of each other. Results: Eleven swine (10 male; mean weight, 43.6 kg +/- 2.6 [SD]) were evaluated with 71 dynamic CT acquisitions. The lymphatic flow rates measured using the first -pass analysis and thresholding techniques were highly correlated with the reference US flow probe measurements (r = 0.99 and 0.91, respectively) and showed good agreement with the reference standard, with Bland -Altman analysis showing small mean differences of 0.04 and 0.05 mL/min, respectively. The first -pass analysis and thresholding techniques also showed good agreement for repeated flow measurements (r = 0.94 and 0.90, respectively), with small mean differences of 0.09 and 0.03 mL/min, respectively. Conclusion: The first -pass analysis and thresholding techniques could be used to accurately and noninvasively quantify TD lymphatic flow using dynamic contrast -enhanced CT lymphangiography.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Successful Visualization of an Indeterminate Hepatic Metastasis From Thyroid Carcinoma Using Contrast-Enhanced CT and Contrast-Enhanced Ultrasound
    Yasui, Junichi
    Shimizu, Toshimasa
    Ando, Takao
    Uchida, Shinjiro
    Shibata, Hidetaka
    Kawakami, Atsushi
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2013, 98 (07) : 2639 - 2640
  • [22] Physiological modelling of dynamic contrast-enhanced MRI in COPD
    Hubbard, Penny
    Parker, Geoff
    Singh, Dave
    Vestbo, Jorgen
    Olsson, Lars
    Wigstrom, Lars
    Young, Simon
    Bondesson, Eva
    Naish, Josephine
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [23] Contrast-enhanced Dedicated Breast CT: Initial Clinical Experience
    Prionas, Nicolas D.
    Lindfors, Karen K.
    Ray, Shonket
    Huang, Shih-Ying
    Beckett, Laurel A.
    Monsky, Wayne L.
    Boone, John M.
    RADIOLOGY, 2010, 256 (03) : 714 - 723
  • [24] The characterization of small hypoattenuating renal masses on contrast-enhanced CT
    Patel, Neesha S.
    Poder, Liina
    Wang, Zhen J.
    Yeh, Benjamin M.
    Qayyum, Aliya
    Jin, Hua
    Coakley, Fergus V.
    CLINICAL IMAGING, 2009, 33 (04) : 295 - 300
  • [25] Imaging Characteristics of Liver Metastases Overlooked at Contrast-Enhanced CT
    Nakai, Hirotsugu
    Arizono, Shigeki
    Isoda, Hiroyoshi
    Togashi, Kaori
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (04) : 782 - 787
  • [26] Evaluation of gallbladder and biliary duct disease using microbubble contrast-enhanced ultrasound
    Meacock, L. M.
    Sellars, M. E.
    Sidhu, P. S.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (991) : 615 - 627
  • [27] Ferumoxtran-10-enhanced MR lymphangiography: Does contrast-enhanced imaging alone suffice for accurate lymph node characterization?
    Harisinghani, MG
    Saksena, MA
    Hahn, PF
    King, B
    Kim, J
    Torabi, MT
    Weissleder, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (01) : 144 - 148
  • [28] FIBROADENOMAS OF THE BREAST - HISTOPATHOLOGICAL DYNAMIC CONTRAST-ENHANCED MR CORRELATION
    GILLES, R
    GARNIER, C
    MEINGAN, P
    ZEMOURA, L
    LUCIDARME, O
    GUINEBRETIERE, JM
    TARDIVON, AA
    ARRIAGADA, R
    EUROPEAN RADIOLOGY, 1995, 5 (05) : 511 - 517
  • [29] Hepatic Perfusion Disorder Associated with Focal Liver Lesions: Contrast-enhanced US Patterns-Correlation Study with Contrast-enhanced CT
    Zhou, Xiang
    Luo, Yan
    Peng, Yu-Lan
    Cai, Wei
    Lu, Qiang
    Lin, Ling
    Sha, Xiao-Xi
    Li, Yong-Zhong
    Zhu, Meng
    RADIOLOGY, 2011, 260 (01) : 274 - 281
  • [30] Ultrafast Dynamic Contrast-enhanced MRI of the Breast: How Is It Used?
    Kataoka, Masako
    Honda, Maya
    Ohashi, Akane
    Yamaguchi, Ken
    Mori, Naoko
    Goto, Mariko
    Fujioka, Tomoyuki
    Mori, Mio
    Kato, Yutaka
    Satake, Hiroko
    Iima, Mami
    Kubota, Kazunori
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (01) : 83 - 94