Dynamic Contrast-enhanced CT Lymphangiography to Quantify Thoracic Duct Lymphatic Flow

被引:1
|
作者
Molloi, Sabee [1 ]
Polivka, Alesh R. [1 ]
Zhao, Yixiao [1 ]
Redmond, Jonas [3 ]
Itkin, Maxim [4 ]
Antunes, Ines [1 ]
Yu, Zhaoxia [2 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Med Sci 1,B-140, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Stat, Med Sci 1,B-140, Irvine, CA 92697 USA
[3] Univ Calif San Diego, Dept Radiol Sci, San Diego, CA USA
[4] Univ Penn, Dept Radiol, Philadelphia, PA USA
关键词
MR LYMPHANGIOGRAPHY; VENOUS-PRESSURE; GADOFOSVESET; DIAGNOSIS; FAILURE;
D O I
10.1148/radiol.230959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: CT lymphangiography has been used to image the lymphatic anatomy and assess lymphatic abnormalities. There is, however, a need to develop a method for quantification of lymphatic flow rate in the thoracic duct (TD). Purpose: To develop and validate a TD lymphatic flow measurement technique using dynamic contrast -enhanced CT lymphangiography. Materials and Methods: Lymphatic flow rate was measured with two techniques: a first -pass analysis technique based on a single compartment model and a thresholding technique distinguishing between opacified and nonopacified voxels within the TD. The measurements were validated in a swine animal model between November 2021 and September 2022. CT images were acquired at 100 kV and 200 mA using a fast -pitched helical scan mode covering the entire TD following contrast material injection into the bilateral inguinal lymph nodes. Two helical CT scans, acquired at the base and peak contrast enhancement of the TD, were used to measure lymphatic flow rate. A US flow probe surgically placed around the TD provided the reference standard measurement. CT lymphatic flow measurements were compared with the reference US flow probe measurements using regression and Bland -Altman analysis. Repeatability was determined using repeated flow measurements within approximately 10 minutes of each other. Results: Eleven swine (10 male; mean weight, 43.6 kg +/- 2.6 [SD]) were evaluated with 71 dynamic CT acquisitions. The lymphatic flow rates measured using the first -pass analysis and thresholding techniques were highly correlated with the reference US flow probe measurements (r = 0.99 and 0.91, respectively) and showed good agreement with the reference standard, with Bland -Altman analysis showing small mean differences of 0.04 and 0.05 mL/min, respectively. The first -pass analysis and thresholding techniques also showed good agreement for repeated flow measurements (r = 0.94 and 0.90, respectively), with small mean differences of 0.09 and 0.03 mL/min, respectively. Conclusion: The first -pass analysis and thresholding techniques could be used to accurately and noninvasively quantify TD lymphatic flow using dynamic contrast -enhanced CT lymphangiography.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Quantification of Thoracic Lymphatic Flow Patterns Using Dynamic Contrast-enhanced MR Lymphangiography
    Zheng, Qiang
    Itkin, Maxim
    Fan, Yong
    RADIOLOGY, 2020, 296 (01) : 202 - 207
  • [2] Dynamic contrast-enhanced magnetic resonance lymphangiography in pediatric patients with central lymphatic system disorders
    Bordonaro, Veronica
    Ciancarella, Paolo
    Ciliberti, Paolo
    Curione, Davide
    Napolitano, Carmela
    Santangelo, Teresa Pia
    Natali, Gian Luigi
    Rollo, Massimo
    Guccione, Paolo
    Pasquini, Luciano
    Secinaro, Aurelio
    RADIOLOGIA MEDICA, 2021, 126 (05): : 737 - 743
  • [3] Dynamic contrast-enhanced magnetic resonance lymphangiography in pediatric patients with central lymphatic system disorders
    Veronica Bordonaro
    Paolo Ciancarella
    Paolo Ciliberti
    Davide Curione
    Carmela Napolitano
    Teresa Pia Santangelo
    Gian Luigi Natali
    Massimo Rollo
    Paolo Guccione
    Luciano Pasquini
    Aurelio Secinaro
    La radiologia medica, 2021, 126 : 737 - 743
  • [4] The utility of dynamic contrast-enhanced intranodal magnetic resonance lymphangiography (MRL) in the investigation of primary lymphatic anomalies
    Ratnam, L. A.
    Mills, M.
    Wale, A.
    Howroyd, L. R.
    Itkin, M.
    Howe, F. A.
    Gordon, K.
    Mansour, S.
    Ostergaard, P.
    Mortimer, P. S.
    CLINICAL RADIOLOGY, 2024, 79 (10) : e1180 - e1188
  • [5] Direct contrast-enhanced magnetic resonance lymphangiography in the diagnosis of persistent occult chylous effusion leak after thoracic duct embolization
    Kiang, Sharon C.
    Ahmed, Khwaja A.
    Barnes, Samual
    Abou-Zamzam, Ahmed M., Jr.
    Tomihama, Roger T.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2019, 7 (02) : 251 - 257
  • [6] Use of Contrast-Enhanced Ultrasound to Determine Thoracic Duct Patency
    Mejia, Erika J.
    Otero, Hansel J.
    Smith, Christopher L.
    Shipman, Molly
    Liu, Mandi
    Pinto, Erin
    DeWitt, Aaron
    Rome, Jonathan J.
    Dori, Yoav
    Biko, David M.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 31 (10) : 1670 - 1674
  • [7] Dynamic Contrast-Enhanced CT in Patients with Pancreatic Cancer
    Eriksen, Rie O.
    Strauch, Louise S.
    Sandgaard, Michael
    Kristensen, Thomas S.
    Nielsen, Michael B.
    Lauridsen, Carsten A.
    DIAGNOSTICS, 2016, 6 (03)
  • [8] Dynamic Contrast-Enhanced Ultrasound of Gastric Cancer: Correlation with Perfusion CT and Histopathology
    Joo, Ijin
    Kim, Se Hyung
    Lee, Dong Ho
    Han, Joon Koo
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (05) : 781 - 790
  • [9] Application of Contrast-Enhanced Ultrasound (CEUS) in Lymphomatous Lymph Nodes: A Comparison between PET/CT and Contrast-Enhanced CT
    Ma, Xuelei
    Ling, Wenwu
    Xia, Fan
    Zhang, Yifan
    Zhu, Chenjing
    He, Jialing
    CONTRAST MEDIA & MOLECULAR IMAGING, 2019,
  • [10] Contrast-enhanced ultrasound for needle biopsy of thoracic lesions
    Liang, Jingchen
    Wang, Duo
    Li, Hongxue
    Zhao, Shengfa
    Chen, Miao
    Li, Hang
    Ding, Zhanling
    Liu, Junjie
    Liu, Lianfeng
    ONCOLOGY LETTERS, 2020, 20 (04)