Fluid-attenuated inversion-recovery sequence with fat suppression as an alternative to contrast-enhanced MRI in pediatric synovitis

被引:2
|
作者
Milks, Kathryn S. [1 ]
Singh, Jasmeet [1 ]
Benedict, Jason A. [2 ]
Rees, Mitchell A. [1 ]
机构
[1] Nationwide Childrens Hosp, Dept Radiol, 700 Childrens Dr, Columbus, OH 43215 USA
[2] Ohio State Univ, Dept Biostat, Wexner Med Ctr, Columbus, OH USA
关键词
FLAIR; Fat saturated; Pediatric; Knee; MRI; Synovitis; RHEUMATOID-ARTHRITIS; JOINT EFFUSION; KNEE; WRIST;
D O I
10.1007/s00247-023-05804-5
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundNon-contrast magnetic resonance imaging (MRI) fluid-attenuated inversion-recovery sequence (FLAIR) with fat suppression (FS) has not been validated in children.ObjectiveCompare FLAIR to T1-weighted post contrast (T1CE) in the detection of knee synovitis.Methods and materialsInstitutional review board (IRB) waived consent. Children who underwent T1CE and FLAIR sequences of the knee on a 3-T magnet from April 2021 to December 2021 were included. Two pediatric radiologists assessed axial FLAIR and T1CE images for synovitis and synovial thickness. Reliability and agreement were assessed. Sensitivities, specificities, and accuracy were calculated for FLAIR using T1CE as reference standard.ResultsIn total, 42 knees (39 patients) were assessed (median age 12.9 years (2.3-17.8 years); 62% male, 38% female). Readers judged 20/42 (48%) knees to have synovitis. Sensitivity of FLAIR for reader 1 was 79% (19/24; 95% CI 0.58, 0.93) and 84% (16/19; 95% CI 0.60, 0.97) for reader 2. Specificity of FLAIR for reader 1 was 94% (17/18; 95% CI 0.73, 1) and 83% (19/23; 95% CI 0.61, 0.95) for reader 2. Accuracy for readers 1 and 2 was 86% (36/42; 95% CI 0.71, 0.95) and 83% (35/42; 95% CI 0.69, 0.93), respectively. Inter-reader reliability was good (0.75-0.90) for synovial measurements for FLAIR (ICC = 0.80; 95% CI 0.71, 0.86) and moderate for T1 CE (ICC = 0.62 (95% CI 0.48, 0.73)).ConclusionFLAIR FS depicts synovium in the pediatric knee with similar reliability to T1 CE and may be an acceptable alternative to contrast in the initial diagnosis of synovitis.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [21] Comparative study between double inversion recovery (DIR) and fluid-attenuated inversion recovery (FLAIR) MRI sequences for detection of cerebral lesions in multiple sclerosis
    Shaima Fattouh Elkholy
    Marianne Abdallah Sabet
    Mohammad Edrees Mohammad
    Ramy Edward Ibrahim Asaad
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [22] Suppression of inner ear signal intensity on fluid-attenuated inversion recovery magnetic resonance imaging in cats with vestibular disease
    Everest, Stephen
    Monteith, Gabrielle
    Gaitero, Luis
    Samarani, Francesca
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2023, 25 (04)
  • [23] Value of fluid-attenuated inversion recovery sequences in early MRI of the brain in neonates with a perinatal hypoxic-ischemic encephalopathy
    Sie, LTL
    Barkhof, F
    Lafeber, HN
    Valk, J
    van der Knaap, MS
    EUROPEAN RADIOLOGY, 2000, 10 (10) : 1594 - 1601
  • [24] Abrogation of fluid suppression in intracranial postcontrast fluid-attenuated inversion recovery magnetic resonance imaging: A clinical and phantom study
    Dickinson, Peter J.
    Jones-Woods, Sarah
    Cissell, Derek D.
    VETERINARY RADIOLOGY & ULTRASOUND, 2018, 59 (04) : 432 - 443
  • [25] Time course of arterial hyperintensity with fast fluid-attenuated inversion-recovery imaging in acute and subacute middle cerebral arterial infarction
    Maeda, M
    Koshimoto, Y
    Uematsu, H
    Yamada, H
    Kimura, H
    Kawamura, Y
    Itoh, H
    Sakuma, H
    Takeda, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 987 - 990
  • [26] T1-weighted fast fluid-attenuated inversion-recovery sequence (T1-FFLAIR) enables the visualization and quantification of fetal brain myelination in utero
    Milos, Ruxandra-Iulia
    Schmidbauer, Victor
    Watzenboeck, Martin L.
    Stuhr, Friedrich
    Gruber, Gerlinde Maria
    Mitter, Christian
    Dovjak, Gregor O.
    Milkovic-Perisa, Marija
    Kostovic, Ivica
    Jovanov-Milosevic, Natasa
    Kasprian, Gregor
    Prayer, Daniela
    EUROPEAN RADIOLOGY, 2024, 34 (07) : 4573 - 4584
  • [27] Fluid-attenuated inversion recovery vascular hyperintensities are not visible using 3D CUBE FLAIR sequence
    Hodel, Jerome
    Leclerc, Xavier
    Rodallec, Mathieu
    Gerber, Sophie
    Blanc, Raphael
    Outteryck, Olivier
    Benadjaoud, Samir
    Rabrait, Cecile
    Zuber, Mathieu
    Pruvo, Jean-Pierre
    Zins, Marc
    EUROPEAN RADIOLOGY, 2013, 23 (07) : 1963 - 1969
  • [28] Value of fluid-attenuated inversion recovery MRI data analyzed by the lesion segmentation toolbox in amyotrophic lateral sclerosis
    Wirth, Anna M.
    Johannesen, Siw
    Khomenko, Andrei
    Baldaranov, Dobri
    Bruun, Tim-Henrik
    Wendl, Christina
    Schuierer, Gerhard
    Greenlee, Mark W.
    Bogdahn, Ulrich
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (02) : 552 - 559
  • [29] Improved visualization of non-transmural scar using slice-selective inversion-recovery delayed contrast-enhanced MRI a preliminary report
    Kim, Daniel
    Lee, Vivian S.
    Srichai, Monvadi B.
    NMR IN BIOMEDICINE, 2007, 20 (02) : 121 - 127
  • [30] Double-inversion recovery with synthetic magnetic resonance: a pilot study for assessing synovitis of the knee joint compared to contrast-enhanced magnetic resonance imaging
    Jisook Yi
    Young Han Lee
    Ho-Taek Song
    Jin-Suck Suh
    European Radiology, 2019, 29 : 2573 - 2580