Fracture load of 4-unit interim fixed partial dentures using 3D-printed and traditionally manufactured materials

被引:5
作者
Greuling, Andreas [1 ,2 ]
Matthies, Annika [1 ]
Eisenburger, Michael [1 ]
机构
[1] Hannover Med Sch, Dept Prosthet Dent & Biomed Mat Sci, Head Mat Sci Lab, Hannover, Germany
[2] Biomed Mat Sci Hannover Med Sch, Dept Prosthet Dent, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
BEARING CAPACITY; BITE FORCE; STRENGTH; CROWN; REHABILITATION; STATE;
D O I
10.1016/j.prosdent.2022.12.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. How the fracture strength of recently introduced 3-dimensionally (3D) printed interim materials compares with that of conventional materials is unclear. Purpose. The purpose of this in vitro study was to compare the fracture load of 4-unit interim fixed partial dentures made from 3 different materials before and after mastication simulation. Material and methods. Based on a master model of a 4-unit fixed partial denture with maxillary left first premolar and second molar abutment teeth, interim restorations were fabricated from 3 different materials (3D-printed, Temporary CB Resin, milled, PMMA for brain, and manually manufactured, Luxatemp Plus). The fixed partial dentures (n=30 for each material) were cemented on 3D-printed model abutment teeth that were connected via a thin latex layer to a polyurethane base block. The fracture load of 15 fixed partial dentures of each material was tested without aging. Another 15 fixed partial dentures of each material were tested after thermomechanical aging. Results. The mean fracture load was between 186 N and 661 N, and all materials showed significant lower fracture loads after aging. Before and after aging (before/after +/- standard deviation) milled (661 +/- 59/568 +/- 52 N) achieved the highest loads before manually manufactured (621 +/- 100/478 +/- 96 N) and 3D-printed (294 +/- 83/186 +/- 70). Conclusions. The 3D-printed interim restoration material and the inherent manufacturing process show significant lower fracture loads than the tested alternatives. However, as the influence of geometric differences could not be quantified, whether this remains true after correcting for geometric differences remains unclear. For the tested interim materials, thermocycling and mastication simulation significantly reduced fracture loads over time, even at loads as low as 50 N. (J Prosthet Dent 2023;129:607.e1-e8)
引用
收藏
页码:607.e1 / 607.e8
页数:8
相关论文
共 35 条
[1]   A study to investigate and compare the physicomechanical properties of experimental and commercial temporary crown and bridge materials [J].
Abdulmohsen, Bana ;
Parker, Sandra ;
Braden, Michael ;
Patel, Mangala P. .
DENTAL MATERIALS, 2016, 32 (02) :200-210
[2]  
Bates J F, 1976, J Oral Rehabil, V3, P57, DOI 10.1111/j.1365-2842.1976.tb00929.x
[3]   3-D printing: The new industrial revolution [J].
Berman, Barry .
BUSINESS HORIZONS, 2012, 55 (02) :155-162
[4]   Injectable technique for direct provisional restoration [J].
Blasi, Alvaro ;
Alnassar, Talal ;
Chiche, Gerard .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2018, 30 (02) :85-88
[5]   Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation [J].
Butz, F ;
Heydecke, G ;
Okutan, M ;
Strub, JR .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (11) :838-843
[6]  
Callister W. D., 2018, Materials Science and Engineering: An Introduction, V10th
[7]  
DeLong R, 1985, Dent Mater, V1, P238, DOI 10.1016/S0109-5641(85)80050-6
[8]  
Dentsply-Sirona, INF ACC SAF DAT
[9]  
DMG, INF ACC SAF DAT
[10]  
Formlabs, INF ACC SAF DAT