A High-Resolution 3D Ultrasound Imaging System Oriented towards a Specific Application in Breast Cancer Detection Based on a 1 x 256 Ring Array

被引:0
作者
Zhang, Junhui [1 ,2 ]
Wu, Fei [1 ,2 ]
Meng, Fansheng [1 ,2 ]
Zhang, Guojun [1 ,2 ]
Wang, Renxin [1 ,2 ]
Yang, Yuhua [1 ,2 ]
Cui, Jiangong [1 ,2 ]
He, Changde [1 ,2 ]
Jia, Licheng [1 ,2 ]
Zhang, Wendong [1 ,2 ]
机构
[1] North Univ China, State Key Lab Instrumentat Sci & Dynam Measurement, Taiyuan 030051, Peoples R China
[2] North Univ China, Sch Instrument & Elect, Natl Key Lab Elect Measurement Technol, Taiyuan 030051, Peoples R China
基金
中国国家自然科学基金;
关键词
3D ultrasound imaging system; ultrasonic tomography; ring array; breast imaging; high-resolution; TOMOGRAPHY;
D O I
10.3390/mi15020209
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the design and development of a high-resolution 3D ultrasound imaging system based on a 1 x 256 piezoelectric ring array, achieving an accuracy of 0.1 mm in both ascending and descending modes. The system achieves an imaging spatial resolution of approximately 0.78 mm. A 256 x 32 cylindrical sensor array and a digital phantom of breast tissue were constructed using the k-Wave toolbox. The signal is acquired layer by layer using 3D acoustic time-domain simulation, resulting in the collection of data from each of the 32 layers. The 1 x 256 ring array moves on a vertical trajectory from the chest wall to the nipple at a constant speed. A data set was collected at intervals of 1.5 mm, resulting in a total of 32 data sets. Surface rendering and volume rendering algorithms were used to reconstruct 3D ultrasound images from the volume data obtained via simulation so that the smallest simulated reconstructed lesion had a diameter of 0.3 mm. The reconstructed three-dimensional image derived from the experimental data exhibits the contour of the breast model along with its internal mass. Reconstructable dimensions can be achieved up to approximately 0.78 mm. The feasibility of applying the system to 3D breast ultrasound imaging has been demonstrated, demonstrating its attributes of resolution, precision, and exceptional efficiency.
引用
收藏
页数:17
相关论文
共 38 条
  • [1] Evaluation of the Reconfiguration of the Data Acquisition System for 3D USCT
    Birk, Matthias
    Hagner, Clemens
    Balzer, Matthias
    Ruiter, Nicole V.
    Huebner, Michael
    Becker, Juergen
    [J]. INTERNATIONAL JOURNAL OF RECONFIGURABLE COMPUTING, 2011, 2011
  • [2] Laser Scanning Guided Localization Imaging with a Laser-Machined Two-Dimensional Flexible Ultrasonic Array
    Chen, Jianzhong
    Liu, Wei
    Gu, Dianbao
    Wu, Dawei
    [J]. MICROMACHINES, 2022, 13 (05)
  • [3] Sparse Convolutional Beamforming for 3-D Ultrafast Ultrasound Imaging
    Cohen, Regev
    Fingerhut, Nitai
    Varray, Francois
    Liebgott, Herve
    Eldar, Yonina C.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (07) : 2444 - 2459
  • [4] Numerical analysis of three-dimensional echo decorrelation imaging
    Cox, Michael T.
    Abbass, Mohamed A.
    Mast, T. Douglas
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 147 (06) : EL478 - EL483
  • [5] 3D ULTRASONIC IMAGE FEATURE LOCALIZATION BASED ON MAGNETIC SCANHEAD TRACKING - IN-VITRO CALIBRATION AND VALIDATION
    DETMER, PR
    BASHEIN, G
    HODGES, T
    BEACH, KW
    FILER, EP
    BURNS, DH
    STRANDNESS, DE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) : 923 - 936
  • [6] Duric N., 2013, P SPIE MEDICAL IMAGI, p86750K
  • [7] Detection of breast cancer with ultrasound tomography: First results with the Computed Ultrasound Risk Evaluation (CURE) prototype
    Duric, Nebojsa
    Littrup, Peter
    Poulo, Lou
    Babkin, Alex
    Pevzner, Roman
    Holsapple, Earle
    Rama, Olsi
    Glide, Carri
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 773 - 785
  • [8] Automated Segmentation of Common Carotid Artery in Ultrasound Images
    Gagan, J. H.
    Shirsat, Harshit S.
    Mathias, Grissel P.
    Mallya, B. Vaibhav
    Andrade, Jasbon
    Rajagopal, K., V
    Kumar, J. R. Harish
    [J]. IEEE ACCESS, 2022, 10 : 58419 - 58430
  • [9] Ultrafast 3-D Ultrasound Imaging Using Row-Column Array-Specific Frame-Multiply-and-Sum Beamforming
    Hansen-Shearer, Joseph
    Lerendegui, Marcelo
    Toulemonde, Matthieu
    Tang, Meng-Xing
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (02) : 480 - 488
  • [10] Fully Automatic Three-Dimensional Ultrasound Imaging Based on Conventional B-Scan
    Huang, Qinghua
    Wu, Bowen
    Lan, Jiulong
    Li, Xuelong
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2018, 12 (02) : 426 - 436