The effect of different orthodontic mini-implant brands and geometry on primary stability (an in vitro study)

被引:0
作者
Abdalla, Khanda Latif [1 ]
Mahmood, Trefa Mohammed Ali [1 ]
机构
[1] Univ Sulaimani, Coll Dent, Dept Pedodont Orthodont & Prevent Dent, Sulaimanyah, Iraq
关键词
Orthodontic mini -implant; Primary stability; Geometry; PULL-OUT STRENGTH; DESIGN CHARACTERISTICS; INSERTION; IMPACT;
D O I
10.1016/j.heliyon.2023.e19858
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: In orthodontic procedures, mini-implants are routinely used as temporary anchorage devices. Early failure is primarily attributed to a variety of issues, which are mostly connected to the quality and geometry of the screw that lead to insufficient primary stability. Objectives: To evaluate the primary stability of different sizes and brands of orthodontic miniimplants by optimizing the insertion torque value (ITV) and to clear out which one has the greatest primary stability among the most widely used mini-implants by orthodontists. Methods: Eighty-two self-drilling mini-implants from three different brands with different sizes were used (Optimus Ortho System (Osteonic made in Korea), Smart anchor (GNI made in Korea) (1.4 x 6, 1.6 x 8 and 1.8 x 10mm) and Morelli (made in Brazil) (1.5 x 6, 1.5 x 8 and 1.5 x 10mm), made from (Ti 6Al 4V). All were drilled at a 60 degrees angle on Sixty artificial bone blocks made from polyurethane foam with a digital torque meter device (Orthonia, Jeil made in Korea), pullout strength (tensile force) was measured with a universal testing machine to find out the best brand and size in the mean of primary stability. Data were analyzed using SPSS Version 25 and JMP Pro Version 16 software using the One-way ANOVA test, the Post hoc and Tukey HCD tests. Results: There were significant differences between the pullout strength of different sizes for the GNI and OSTEONIC brands, while for the MORELLI brand there were no significant differences between the three different sizes considering ITV (10Ncm) whereas for ITV (20Ncm) there was a significant difference between the different sizes for the pullout of all three brands. GNI was the best brand for all the selected sizes with ITV (10Ncm) and size 1.4 x 6 for ITV (20Ncm), whereas OSTEONIC sizes 1.6 x 8 and 1.8 x 10 were the best for ITV (20Ncm) in term of primary stability. Conclusion: GNI screws were demonstrated higher primary among the three widely used brands followed by OSTEONIC for size 1.6 x 8 and 1.8 x 10 while MORELLI was the least resistant to dislodgement for the two torque insertion values 10 N/cm and 20 N/cm.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Effects of Drilling Technology on Mini-Implant Primary Stability: A Comparison of the Mechanical Drilling and Femtosecond Laser Ablation
    Zhang, Wenbin
    Alghannam, Fahad
    Zhu, Yingchao
    Zhang, Jianfei
    Wohl, Gregory R.
    Haugen, Harold K.
    Qin, Zhipeng
    Xie, Guoqiang
    Fang, Qiyin
    Shen, Steve Guofang
    [J]. FRONTIERS IN PHYSICS, 2021, 9
  • [32] Computed tomography assessment of maxillary bone density for orthodontic mini-implant placement with respect to vertical growth patterns
    Arvind TR, Prasanna
    Jain, Ravindra Kumar
    [J]. JOURNAL OF ORTHODONTICS, 2021, 48 (04) : 392 - 402
  • [33] Accuracy of torque-limiting devices used for mini-implant placement-an in vitro study
    Pauls, Alexander
    Nienkemper, Manuel
    Drescher, Dieter
    [J]. JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2013, 74 (02): : 124 - 136
  • [34] Compensating for poor primary implant stability in different bone densities by varying implant geometry: a laboratory study
    Moehlhenrich, S. C.
    Heussen, N.
    Elvers, D.
    Steiner, T.
    Hoelzle, F.
    Modabber, A.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (12) : 1514 - 1520
  • [35] The Influence of the Diameter of Orthodontic Mini-Implants on Primary Stability: Bending Tests-An In Vitro Study
    Sousa-Santos, Catarina
    Sousa-Santos, Sofia
    Mendes, Joana
    Coelho, Carlos
    Aroso, Carlos
    Sousa-Santos, Primavera
    Mendes, Jose Manuel
    [J]. MATERIALS, 2024, 17 (13)
  • [36] Reliability and Correlation of Different Devices for the Evaluation of Primary Implant Stability: An In Vitro Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Peleg, Maia
    Sebaoun, Alon
    Beitlitum, Ilan
    [J]. MATERIALS, 2021, 14 (19)
  • [37] Comparing the Primary Stability of Three Different Orthodontic Mini-Implants with Various Dimensions on Artificial Bone
    Mohammed, Haneen I.
    Al-Sheakli, Iman I.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (01): : 128 - 134
  • [38] Comparative Evaluation of Primary Stability of Two Different Types of Orthodontic Mini-Implants
    Jyotirmay, Singh
    Singh, Sanjay Kumar
    Gupta, Abhinav Raj
    Nayak, Subhash Chandra
    Vatsa, Ritesh
    Priyadarshni, Priyanka
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 128 - 131
  • [39] Optimal Buccal Site for Mini-Implant Placement on Attached Gingiva of Posterior Maxilla: A CBCT Study
    Vasoglou, Georgios
    Apostolopoulos, Konstantinos
    Vasoglou, Michail
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (12):
  • [40] Three-dimensional digital imaging analysis of the palatal bone thickness for orthodontic mini-implant insertion - determination of the safe zone and angulation
    Schubert, Hanna
    Matta, Ragai
    Seidel, Anna
    Adler, Werner
    Wichmann, Manfred
    Kesting, Marco
    Lutz, Rainer
    [J]. BMC ORAL HEALTH, 2024, 24 (01):