The effect of different orthodontic mini-implant brands and geometry on primary stability (an in vitro study)

被引:1
作者
Abdalla, Khanda Latif [1 ]
Mahmood, Trefa Mohammed Ali [1 ]
机构
[1] Univ Sulaimani, Coll Dent, Dept Pedodont Orthodont & Prevent Dent, Sulaimanyah, Iraq
关键词
Orthodontic mini -implant; Primary stability; Geometry; PULL-OUT STRENGTH; DESIGN CHARACTERISTICS; INSERTION; IMPACT;
D O I
10.1016/j.heliyon.2023.e19858
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: In orthodontic procedures, mini-implants are routinely used as temporary anchorage devices. Early failure is primarily attributed to a variety of issues, which are mostly connected to the quality and geometry of the screw that lead to insufficient primary stability. Objectives: To evaluate the primary stability of different sizes and brands of orthodontic miniimplants by optimizing the insertion torque value (ITV) and to clear out which one has the greatest primary stability among the most widely used mini-implants by orthodontists. Methods: Eighty-two self-drilling mini-implants from three different brands with different sizes were used (Optimus Ortho System (Osteonic made in Korea), Smart anchor (GNI made in Korea) (1.4 x 6, 1.6 x 8 and 1.8 x 10mm) and Morelli (made in Brazil) (1.5 x 6, 1.5 x 8 and 1.5 x 10mm), made from (Ti 6Al 4V). All were drilled at a 60 degrees angle on Sixty artificial bone blocks made from polyurethane foam with a digital torque meter device (Orthonia, Jeil made in Korea), pullout strength (tensile force) was measured with a universal testing machine to find out the best brand and size in the mean of primary stability. Data were analyzed using SPSS Version 25 and JMP Pro Version 16 software using the One-way ANOVA test, the Post hoc and Tukey HCD tests. Results: There were significant differences between the pullout strength of different sizes for the GNI and OSTEONIC brands, while for the MORELLI brand there were no significant differences between the three different sizes considering ITV (10Ncm) whereas for ITV (20Ncm) there was a significant difference between the different sizes for the pullout of all three brands. GNI was the best brand for all the selected sizes with ITV (10Ncm) and size 1.4 x 6 for ITV (20Ncm), whereas OSTEONIC sizes 1.6 x 8 and 1.8 x 10 were the best for ITV (20Ncm) in term of primary stability. Conclusion: GNI screws were demonstrated higher primary among the three widely used brands followed by OSTEONIC for size 1.6 x 8 and 1.8 x 10 while MORELLI was the least resistant to dislodgement for the two torque insertion values 10 N/cm and 20 N/cm.
引用
收藏
页数:16
相关论文
共 50 条
[21]   Impact of Implant Design and Bone Properties on the Primary Stability of Orthodontic Mini-Implants [J].
Redzepagic-Vrazalica, Lejla ;
Mesic, Elmedin ;
Pervan, Nedim ;
Hadziabdic, Vahidin ;
Delic, Muamer ;
Glusac, Mirza .
APPLIED SCIENCES-BASEL, 2021, 11 (03) :1-10
[22]   Analysis of the association of IL4 polymorphisms with orthodontic mini-implant loss [J].
Lopes, T. F. ;
Souza, C. M. ;
Reichow, A. M. ;
Melo, A. C. ;
Trevilatto, P. C. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (07) :982-988
[23]   Influence of orthodontic mini-implant penetration of the maxillary sinus in the infrazygomatic crest region [J].
Jia, Xueting ;
Chen, Xing ;
Huang, Xiaofeng .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 153 (05) :656-661
[24]   Three-dimensional finite element analysis of the deformation of the human mandible: a preliminary study from the perspective of orthodontic mini-implant stability [J].
Baek, Sun-Hye ;
Cha, Hyun-Suk ;
Cha, Jung-Yul ;
Moon, Yoon-Shik ;
Sung, Sang-Jin .
KOREAN JOURNAL OF ORTHODONTICS, 2012, 42 (04) :159-168
[25]   Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study [J].
Raz, Perry ;
Meir, Haya ;
Levartovsky, Shifra ;
Sebaoun, Alon ;
Beitlitum, Ilan .
MATERIALS, 2022, 15 (09)
[26]   Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis [J].
Bo Zhang ;
Xinqi Huang ;
Sibei Huo ;
Chenghao Zhang ;
Xiao Cen ;
Zhihe Zhao .
Lasers in Medical Science, 2021, 36 :1557-1566
[27]   Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis [J].
Zhang, Bo ;
Huang, Xinqi ;
Huo, Sibei ;
Zhang, Chenghao ;
Cen, Xiao ;
Zhao, Zhihe .
LASERS IN MEDICAL SCIENCE, 2021, 36 (08) :1557-1566
[28]   Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study [J].
Ibrahim, Ahmad ;
Heitzer, Marius ;
Bock, Anna ;
Peters, Florian ;
Moehlhenrich, Stephan Christian ;
Hoelzle, Frank ;
Modabber, Ali ;
Kniha, Kristian .
MATERIALS, 2020, 13 (19) :1-16
[29]   The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study [J].
Cho, Il-Sik ;
Choo, HyeRan ;
Kim, Seong-Kyun ;
Shin, Yun-Seob ;
Kim, Duck-Su ;
Kim, Seong-Hun ;
Chung, Kyu-Rhim ;
Huang, John C. .
KOREAN JOURNAL OF ORTHODONTICS, 2011, 41 (05) :354-360
[30]   Hydroxyapatite, polyetheretherketone, and stainless steel as orthodontic mini-implant biomaterial candidates: A bioinformatic approach [J].
Ardani, I. Gusti Aju Wahju ;
Sugitto, Mario Raphael ;
Aufa, Hashfi Raushan ;
Kharisma, Viol Dhea ;
Putranto, Ananda Firman ;
Gunung, Guruh Putra ;
Perkasa, Ida Bagus Agastya ;
Syaifudin, Achmad ;
Situmorang, Putri Cahaya ;
Hassan, Rozita ;
Nugraha, Alexander Patera .
JOURNAL OF PHARMACY & PHARMACOGNOSY RESEARCH, 2025, 13 (03) :801-815