The effect of different orthodontic mini-implant brands and geometry on primary stability (an in vitro study)

被引:0
作者
Abdalla, Khanda Latif [1 ]
Mahmood, Trefa Mohammed Ali [1 ]
机构
[1] Univ Sulaimani, Coll Dent, Dept Pedodont Orthodont & Prevent Dent, Sulaimanyah, Iraq
关键词
Orthodontic mini -implant; Primary stability; Geometry; PULL-OUT STRENGTH; DESIGN CHARACTERISTICS; INSERTION; IMPACT;
D O I
10.1016/j.heliyon.2023.e19858
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: In orthodontic procedures, mini-implants are routinely used as temporary anchorage devices. Early failure is primarily attributed to a variety of issues, which are mostly connected to the quality and geometry of the screw that lead to insufficient primary stability. Objectives: To evaluate the primary stability of different sizes and brands of orthodontic miniimplants by optimizing the insertion torque value (ITV) and to clear out which one has the greatest primary stability among the most widely used mini-implants by orthodontists. Methods: Eighty-two self-drilling mini-implants from three different brands with different sizes were used (Optimus Ortho System (Osteonic made in Korea), Smart anchor (GNI made in Korea) (1.4 x 6, 1.6 x 8 and 1.8 x 10mm) and Morelli (made in Brazil) (1.5 x 6, 1.5 x 8 and 1.5 x 10mm), made from (Ti 6Al 4V). All were drilled at a 60 degrees angle on Sixty artificial bone blocks made from polyurethane foam with a digital torque meter device (Orthonia, Jeil made in Korea), pullout strength (tensile force) was measured with a universal testing machine to find out the best brand and size in the mean of primary stability. Data were analyzed using SPSS Version 25 and JMP Pro Version 16 software using the One-way ANOVA test, the Post hoc and Tukey HCD tests. Results: There were significant differences between the pullout strength of different sizes for the GNI and OSTEONIC brands, while for the MORELLI brand there were no significant differences between the three different sizes considering ITV (10Ncm) whereas for ITV (20Ncm) there was a significant difference between the different sizes for the pullout of all three brands. GNI was the best brand for all the selected sizes with ITV (10Ncm) and size 1.4 x 6 for ITV (20Ncm), whereas OSTEONIC sizes 1.6 x 8 and 1.8 x 10 were the best for ITV (20Ncm) in term of primary stability. Conclusion: GNI screws were demonstrated higher primary among the three widely used brands followed by OSTEONIC for size 1.6 x 8 and 1.8 x 10 while MORELLI was the least resistant to dislodgement for the two torque insertion values 10 N/cm and 20 N/cm.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Impact of implant design on primary stability of orthodontic mini-implants
    Wilmes, Benedict
    Ottenstreuer, Stephanie
    Su, Yu-Yu
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (01): : 42 - 50
  • [22] Analysis of the association of IL4 polymorphisms with orthodontic mini-implant loss
    Lopes, T. F.
    Souza, C. M.
    Reichow, A. M.
    Melo, A. C.
    Trevilatto, P. C.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (07) : 982 - 988
  • [23] Influence of orthodontic mini-implant penetration of the maxillary sinus in the infrazygomatic crest region
    Jia, Xueting
    Chen, Xing
    Huang, Xiaofeng
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 153 (05) : 656 - 661
  • [24] Three-dimensional finite element analysis of the deformation of the human mandible: a preliminary study from the perspective of orthodontic mini-implant stability
    Baek, Sun-Hye
    Cha, Hyun-Suk
    Cha, Jung-Yul
    Moon, Yoon-Shik
    Sung, Sang-Jin
    KOREAN JOURNAL OF ORTHODONTICS, 2012, 42 (04) : 159 - 168
  • [25] Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis
    Bo Zhang
    Xinqi Huang
    Sibei Huo
    Chenghao Zhang
    Xiao Cen
    Zhihe Zhao
    Lasers in Medical Science, 2021, 36 : 1557 - 1566
  • [26] Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Sebaoun, Alon
    Beitlitum, Ilan
    MATERIALS, 2022, 15 (09)
  • [27] Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis
    Zhang, Bo
    Huang, Xinqi
    Huo, Sibei
    Zhang, Chenghao
    Cen, Xiao
    Zhao, Zhihe
    LASERS IN MEDICAL SCIENCE, 2021, 36 (08) : 1557 - 1566
  • [28] Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study
    Ibrahim, Ahmad
    Heitzer, Marius
    Bock, Anna
    Peters, Florian
    Moehlhenrich, Stephan Christian
    Hoelzle, Frank
    Modabber, Ali
    Kniha, Kristian
    MATERIALS, 2020, 13 (19) : 1 - 16
  • [29] The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study
    Cho, Il-Sik
    Choo, HyeRan
    Kim, Seong-Kyun
    Shin, Yun-Seob
    Kim, Duck-Su
    Kim, Seong-Hun
    Chung, Kyu-Rhim
    Huang, John C.
    KOREAN JOURNAL OF ORTHODONTICS, 2011, 41 (05): : 354 - 360
  • [30] Hydroxyapatite, polyetheretherketone, and stainless steel as orthodontic mini-implant biomaterial candidates: A bioinformatic approach
    Ardani, I. Gusti Aju Wahju
    Sugitto, Mario Raphael
    Aufa, Hashfi Raushan
    Kharisma, Viol Dhea
    Putranto, Ananda Firman
    Gunung, Guruh Putra
    Perkasa, Ida Bagus Agastya
    Syaifudin, Achmad
    Situmorang, Putri Cahaya
    Hassan, Rozita
    Nugraha, Alexander Patera
    JOURNAL OF PHARMACY & PHARMACOGNOSY RESEARCH, 2025, 13 (03): : 801 - 815